Skip to content

Fuji vs Yoau heat pumps

Measured against models of the same size and duct type, Fuji scores higher on 5 of the 6 ratings. Fuji has 12 outdoor models, Yoau has 12 outdoor models. Fuji and Yoau have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Fuji and Yoau on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Fuji scores higher on 5 of the 6 ratings.
  • Fuji
  • Yoau
  • Other ranked manufacturers
FujiYoau

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFujiYoau
Efficiency index52% (higher)median —32% (higher)median —
COP at 5°F54%median 2.0067%median 2.32
Capacity retention at 5°F57% (higher)median 78%30% (higher)median 70%
HSPF255% (higher)median 9.014% (higher)median 7.5
SEER259% (higher)median 19.044% (higher)median 16.4
EER237% (higher)median 10.99% (higher)median 9.9
Heating capacity at 5°F60% (higher)median 24,200 Btu/h20% (higher)median 6,300 Btu/h
Outdoor models1212
AHRI certifications1212

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFujiYoau
CEE 2025 Tier 1 (Split ASHP)75%9 models0%0 models
CEE 2026 Tier 1 (Split ASHP)75%9 models0%0 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)66.7%8 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 1 groups where both have models
  • Fuji
  • Yoau
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFujiYoau
Ducted, up to 1.5 tons1 · index 47%12 · index 32%
Ducted, 2 tons1 · index 38%None
Ducted, 2.5–3 tons2 · index 43%None
Ducted, 3.5–4.5 tons2 · index 51%None
Non-ducted, up to 1.5 tons1 · index 60%None
Non-ducted, 2 tons1 · index 72%None
Non-ducted, 2.5–3 tons4 · index 54%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFujiCold-climate score, best modelYoauCold-climate score, best model
Ducted, up to 1.5 tons49.5(50 is the typical model of its size class) (higher)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models qualify · AHRI 21867983641.3(50 is the typical model of its size class)YWD-10HD2/FC-6-WAlso listed as YWD-10HD2/FC-6-W-1, YWD-10HD2/FC-6-W-2, YWD-10HD2/FC-3-W, YWD1-10HD2/FC-3-W-1 and 2 more12 of 12 models qualify · AHRI 218718524
Ducted, 2 tons46.6(50 is the typical model of its size class)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models qualify · AHRI 218679837No models in this size class
Ducted, 2.5–3 tonsNone on this board (0 of 2 models qualify)No models in this size class
Ducted, 3.5–4.5 tons72.3(50 is the typical model of its size class)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models qualify · AHRI 218679840No models in this size class
Non-ducted, up to 1.5 tons64.6(50 is the typical model of its size class)FM2H18D230U1 of 1 models qualify · AHRI 218668536No models in this size class
Non-ducted, 2 tons67.5(50 is the typical model of its size class)FM3H24D230U1 of 1 models qualify · AHRI 218668537No models in this size class
Non-ducted, 2.5–3 tons59.0(50 is the typical model of its size class)FM4H42D230U4 of 4 models qualify · AHRI 218668540No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFujiAll-around score, best modelYoauAll-around score, best model
Ducted, up to 1.5 tons47.2(50 is the typical model of its size class) (higher)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models have all five ratings · AHRI 21867983636.3(50 is the typical model of its size class)YWD-10HD2/FC-6-WAlso listed as YWD-10HD2/FC-6-W-1, YWD-10HD2/FC-6-W-2, YWD-10HD2/FC-3-W, YWD1-10HD2/FC-3-W-1 and 2 more12 of 12 models have all five ratings · AHRI 218718524
Ducted, 2 tons37.6(50 is the typical model of its size class)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models have all five ratings · AHRI 218679837No models in this size class
Ducted, 2.5–3 tons43.0(50 is the typical model of its size class)FAH30HP230Uwith ducted air handler FAH30HP230N2 of 2 models have all five ratings · AHRI 218679838No models in this size class
Ducted, 3.5–4.5 tons53.2(50 is the typical model of its size class)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models have all five ratings · AHRI 218679840No models in this size class
Non-ducted, up to 1.5 tons59.8(50 is the typical model of its size class)FM2H18D230U1 of 1 models have all five ratings · AHRI 218668536No models in this size class
Non-ducted, 2 tons71.8(50 is the typical model of its size class)FM3H24D230U1 of 1 models have all five ratings · AHRI 218668537No models in this size class
Non-ducted, 2.5–3 tons66.6(50 is the typical model of its size class)FM4H30D230U4 of 4 models have all five ratings · AHRI 218668538No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFujiYoau
COP at 5°Fbeats 69% · 2.10FAH48HP230UDucted, 3.5–4.5 tonsbeats 89% · 2.32YWD-10HD2/FC-6-WAlso listed as YWD-10HD2/FC-6-W-1, YWD-10HD2/FC-6-W-2, YWD-10HD2/FC-3-W, YWD1-10HD2/FC-3-W-1 and 2 moreDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 79% · 90%FM3H24D230UNon-ducted, 2 tonsbeats 41% · 72%YWD-10HD/FC-6-WAlso listed as YWD3-10HD/FC-6, YWD3-10HD/FC-6-W, YWD1-10HD/FC-3-W, YWA-10HD/FC-3-WDucted, up to 1.5 tons
HSPF2beats 69% · 9.0FAH48HP230UDucted, 3.5–4.5 tonsbeats 13% · 7.5YWD-10HD/FC-6-WAlso listed as YWD3-10HD/FC-6, YWD3-10HD/FC-6-W, YWD1-10HD/FC-3-W, YWA-10HD/FC-3-WDucted, up to 1.5 tons
SEER2beats 79% · 23.0FM3H24D230UNon-ducted, 2 tonsbeats 51% · 16.4YWD-10HD2/FC-6-WAlso listed as YWD-10HD2/FC-6-W-1, YWD-10HD2/FC-6-W-2, YWD-10HD2/FC-3-W, YWD1-10HD2/FC-3-W-1 and 2 moreDucted, up to 1.5 tons
EER2beats 75% · 12.5FM4H30D230UNon-ducted, 2.5–3 tonsbeats 8% · 9.9YWD-10HD2/FC-6-WAlso listed as YWD-10HD2/FC-6-W-1, YWD-10HD2/FC-6-W-2, YWD-10HD2/FC-3-W, YWD1-10HD2/FC-3-W-1 and 2 moreDucted, up to 1.5 tons
Heating capacity at 5°Fbeats 85% · 14,500 Btu/hFM2H18D230UNon-ducted, up to 1.5 tonsbeats 22% · 6,500 Btu/hYWD-10HD/FC-6-WAlso listed as YWD3-10HD/FC-6, YWD3-10HD/FC-6-W, YWD1-10HD/FC-3-W, YWA-10HD/FC-3-WDucted, up to 1.5 tons

More comparisons