Fuji heat pump efficiency: 22 outdoor models compared
Fuji has 22 heat pump outdoor models certified with this refrigerant group, in 22 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Fuji makes. Fuji has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 22
- AHRI certifications
- 22
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (19 models)
- Meet CEE 2025
- 63.6%
- 14 models
How Fuji compares with comparable models
- Fuji
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index19 models scored | 50% | Not ranked | — |
| COP at 5°F22 models scored | 58% | Not ranked | 2.00 |
| Capacity retention at 5°F19 models scored | 57% | Not ranked | 78% |
| HSPF222 models scored | 45% | Not ranked | 9.0 |
| SEER222 models scored | 52% | Not ranked | 20.0 |
| EER222 models scored | 35% | Not ranked | 11.0 |
| Heating capacity at 5°F20 models scored | 53% | Not ranked | 19,700 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 63.6% | 14 |
| CEE 2026 Tier 1 (Split ASHP) | 63.6% | 14 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 63.6% | 14 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Fuji (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 49% | 64% | 31% | 58% |
| Ducted, 2 tons | 1 | 38% | 38% | 44% | 43% |
| Ducted, 2.5 to 3 tons | 2 | 43% | 46% | 58% | 62% |
| Ducted, 3.5 to 4.5 tons | 2 | 51% | 61% | 72% | 54% |
| Non-ducted, up to 1.5 tons | 9 | 49% | 62% | 33% | 42% |
| Non-ducted, 2 tons | 3 | 56% | 61% | 52% | 59% |
| Non-ducted, 2.5 to 3 tons | 4 | 55% | 53% | 50% | 61% |
Every Fuji model in the market
- Fuji models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Fuji models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1FAU24HPI230M22UFujiwith ductless indoor unit FAU24HPI230M22N | 2 tons23,000 Btu/h · Non-ducted | 87% | 2.20 | 10.0 | 20,800 | 22.0 | CEE 25CEE 26Xcel | 1 | 218071064 | Non-ducted, 2 tons | 78.6 |
| 2FAH48HP230UFujiwith ducted air handler FAH48HP230N | 4 tons48,000 Btu/h · Ducted | 84% | 2.10 | 9.0 | 40,500 | 16.0 | None | 1 | 218679840 | Ducted, 3.5 to 4.5 tons | 72.3 |
| 3FM3H24D230UFuji | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 21,600 | 23.0 | CEE 25CEE 26Xcel | 1 | 218668537 | Non-ducted, 2 tons | 68.5 |
| 4FM2H18D230UFuji | 1.5 tons17,700 Btu/h · Non-ducted | 81% | 2.00 | 10.0 | 14,500 | 22.0 | CEE 25CEE 26Xcel | 1 | 218668536 | Non-ducted, up to 1.5 tons | 66.1 |
| 5FAH60HP230UFujiwith ducted air handler FAH60HP230N | 4.5 tons55,000 Btu/h · Ducted | 75% | 2.00 | 9.0 | 41,500 | 16.0 | None | 1 | 218679841 | Ducted, 3.5 to 4.5 tons | 63.0 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1FM3H24D230UFuji | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 218668537 | Non-ducted, 2 tons | 73.3 | 68.5 | 78.2 | 68.5 |
| 2FAU24HPI230M22UFujiwith ductless indoor unit FAU24HPI230M22N | 2 tons23,000 Btu/h · Non-ducted | 87% | 2.20 | 10.0 | 22.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 218071064 | Non-ducted, 2 tons | 70.2 | 78.6 | 61.8 | 78.6 |
| 3FM4H30D230UFuji | 2.5 tons30,000 Btu/h · Non-ducted | 82% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 218668538 | Non-ducted, 2.5 to 3 tons | 67.4 | 58.3 | 76.5 | 58.3 |
| 4FM4H36D230UFuji | 3 tons36,000 Btu/h · Non-ducted | 71% | 2.00 | 10.0 | 23.0 | 12.3 | CEE 25CEE 26Xcel | 1 | 218668539 | Non-ducted, 2.5 to 3 tons | 63.4 | 52.1 | 74.8 | 52.1 |
| 5FM2H18D230UFuji | 1.5 tons17,700 Btu/h · Non-ducted | 81% | 2.00 | 10.0 | 22.0 | 12.3 | CEE 25CEE 26Xcel | 1 | 218668536 | Non-ducted, up to 1.5 tons | 62.0 | 66.1 | 57.8 | 66.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | FAU18HPI230M22U | 2.20 | Non-ducted, up to 1.5 tons | 86% | 218071062 |
| Capacity retention at 5°F | FM3H24D230U | 90% | Non-ducted, 2 tons | 81% | 218668537 |
| HSPF2 | FAU24HPI230M22U | 10.0 | Non-ducted, 2 tons | 71% | 218071064 |
| SEER2 | FM3H24D230U | 23.0 | Non-ducted, 2 tons | 81% | 218668537 |
| EER2 | FM4H30D230U | 12.5 | Non-ducted, 2.5 to 3 tons | 76% | 218668538 |
| Heating capacity at 5°F | FM2H18D230U | 14,500 Btu/h | Non-ducted, up to 1.5 tons | 86% | 218668536 |
Fuji size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 50.4(50 is the typical model of its size class)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models qualify · AHRI 218679836 | 49.1(50 is the typical model of its size class)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models have all five ratings · AHRI 218679836 |
| Ducted, 2 tons | 46.4(50 is the typical model of its size class)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models qualify · AHRI 218679837 | 37.5(50 is the typical model of its size class)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models have all five ratings · AHRI 218679837 |
| Ducted, 2.5 to 3 tons | None on this board (0 of 2 models qualify) | 42.8(50 is the typical model of its size class)FAH30HP230Uwith ducted air handler FAH30HP230N2 of 2 models have all five ratings · AHRI 218679838 |
| Ducted, 3.5 to 4.5 tons | 72.3(50 is the typical model of its size class)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models qualify · AHRI 218679840 | 53.5(50 is the typical model of its size class)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models have all five ratings · AHRI 218679840 |
| Non-ducted, up to 1.5 tons | 66.1(50 is the typical model of its size class)FM2H18D230U6 of 9 models qualify · AHRI 218668536 | 62.0(50 is the typical model of its size class)FM2H18D230U6 of 9 models have all five ratings · AHRI 218668536 |
| Non-ducted, 2 tons | 78.6(50 is the typical model of its size class)FAU24HPI230M22Uwith ductless indoor unit FAU24HPI230M22N2 of 3 models qualify · AHRI 218071064 | 73.3(50 is the typical model of its size class)FM3H24D230U3 of 3 models have all five ratings · AHRI 218668537 |
| Non-ducted, 2.5 to 3 tons | 59.7(50 is the typical model of its size class)FM4H42D230U4 of 4 models qualify · AHRI 218668540 | 67.4(50 is the typical model of its size class)FM4H30D230U4 of 4 models have all five ratings · AHRI 218668538 |
Newest Fuji certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| FBU36HPI230L20UFujiwith ductless indoor unit FBU36HPI230L20N | 3 tons33,600 Btu/h · Non-ducted | 2.00 | 70% | 8.6 | 20.0 | CEE 25CEE 26Xcel | 1 | 218775082 |
| FAH60HP230UFujiwith ducted air handler FAH60HP230N | 4.5 tons55,000 Btu/h · Ducted | 2.00 | 75% | 9.0 | 16.0 | None | 1 | 218679841 |
| FAH48HP230UFujiwith ducted air handler FAH48HP230N | 4 tons48,000 Btu/h · Ducted | 2.10 | 84% | 9.0 | 16.0 | None | 1 | 218679840 |
| FAH36HP230UFujiwith ducted air handler FAH36HP230N | 3 tons35,000 Btu/h · Ducted | 2.00 | 66% | 8.6 | 17.0 | None | 1 | 218679839 |
| FAH30HP230UFujiwith ducted air handler FAH30HP230N | 2.5 tons30,000 Btu/h · Ducted | 1.90 | 69% | 8.5 | 18.0 | CEE 25CEE 26 | 1 | 218679838 |
Compare Fuji