Fuji vs SHARBO heat pumps
Measured against models of the same size and duct type, Fuji scores higher on 3 of the 6 ratings. Fuji has 22 outdoor models, SHARBO has 22 outdoor models. Fuji and SHARBO have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Fuji
- SHARBO
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Fuji | SHARBO |
|---|---|---|
| Efficiency index | 50%median — | —median — |
| COP at 5°F | 58%median 2.00 | —median — |
| Capacity retention at 5°F | 57%median 78% | —median — |
| HSPF2 | 45% (higher)median 9.0 | 3% (higher)median 8.0 |
| SEER2 | 52% (higher)median 20.0 | 10% (higher)median 17.0 |
| EER2 | 35% (higher)median 11.0 | 12% (higher)median 9.7 |
| Heating capacity at 5°F | 53%median 19,700 Btu/h | —median — |
| Outdoor models | 22 | 22 |
| AHRI certifications | 22 | 22 |
Share of models meeting each standard
| Standard | Fuji | SHARBO |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 63.6%14 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 63.6%14 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 63.6%14 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Fuji
- SHARBO
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Fuji | SHARBO |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 49% | None |
| Ducted, 2 tons | 1 · index 37% | None |
| Ducted, 2.5 to 3 tons | 2 · index 43% | None |
| Ducted, 3.5 to 4.5 tons | 2 · index 51% | None |
| Non-ducted, up to 1.5 tons | 9 · index 49% | 12 · index — |
| Non-ducted, 2 tons | 3 · index 56% | 4 · index — |
| Non-ducted, 2.5 to 3 tons | 4 · index 55% | 6 · index — |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FujiCold-climate score, best model | SHARBOCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 50.0(50 is the typical model of its size class)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models qualify · AHRI 218679836 | No models in this size class |
| Ducted, 2 tons | 46.3(50 is the typical model of its size class)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models qualify · AHRI 218679837 | No models in this size class |
| Ducted, 2.5 to 3 tons | None on this board (0 of 2 models qualify) | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 72.3(50 is the typical model of its size class)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models qualify · AHRI 218679840 | No models in this size class |
| Non-ducted, up to 1.5 tons | 66.2(50 is the typical model of its size class)FM2H18D230U6 of 9 models qualify · AHRI 218668536 | None on this board (0 of 12 models qualify) |
| Non-ducted, 2 tons | 78.6(50 is the typical model of its size class)FAU24HPI230M22Uwith ductless indoor unit FAU24HPI230M22N2 of 3 models qualify · AHRI 218071064 | None on this board (0 of 4 models qualify) |
| Non-ducted, 2.5 to 3 tons | 59.7(50 is the typical model of its size class)FM4H42D230U4 of 4 models qualify · AHRI 218668540 | None on this board (0 of 6 models qualify) |
All-around best
| Size and duct type | FujiAll-around score, best model | SHARBOAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 48.7(50 is the typical model of its size class)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models have all five ratings · AHRI 218679836 | No models in this size class |
| Ducted, 2 tons | 37.4(50 is the typical model of its size class)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models have all five ratings · AHRI 218679837 | No models in this size class |
| Ducted, 2.5 to 3 tons | 42.8(50 is the typical model of its size class)FAH30HP230Uwith ducted air handler FAH30HP230N2 of 2 models have all five ratings · AHRI 218679838 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 53.5(50 is the typical model of its size class)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models have all five ratings · AHRI 218679840 | No models in this size class |
| Non-ducted, up to 1.5 tons | 62.0(50 is the typical model of its size class)FM2H18D230U6 of 9 models have all five ratings · AHRI 218668536 | None on this board (0 of 12 models have all five ratings) |
| Non-ducted, 2 tons | 73.3(50 is the typical model of its size class)FM3H24D230U3 of 3 models have all five ratings · AHRI 218668537 | None on this board (0 of 4 models have all five ratings) |
| Non-ducted, 2.5 to 3 tons | 67.4(50 is the typical model of its size class)FM4H30D230U4 of 4 models have all five ratings · AHRI 218668538 | None on this board (0 of 6 models have all five ratings) |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Fuji | SHARBO |
|---|---|---|
| COP at 5°F | beats 86% · 2.20FAU18HPI230M22UNon-ducted, up to 1.5 tons | — |
| Capacity retention at 5°F | beats 81% · 90%FM3H24D230UNon-ducted, 2 tons | — |
| HSPF2 | beats 71% · 10.0FAU24HPI230M22UNon-ducted, 2 tons | beats 6% · 8.3AU-12H61RG-700A-19(BP14)Also listed as AU-12H63RG-700A-19(BP14)Non-ducted, up to 1.5 tons |
| SEER2 | beats 81% · 23.0FM3H24D230UNon-ducted, 2 tons | beats 26% · 19.0AU-24H63RN-820A-19(BP14)Non-ducted, 2 tons |
| EER2 | beats 76% · 12.5FM4H30D230UNon-ducted, 2.5 to 3 tons | beats 15% · 9.8AUS-24H63RN4-820A(BP14)Also listed as AU-24H63RN-820A(BP14), AEPL**MHV17S2431S1ANon-ducted, 2 tons |
| Heating capacity at 5°F | beats 86% · 14,500 Btu/hFM2H18D230UNon-ducted, up to 1.5 tons | — |