Skip to content

Dynoaire vs Fuji heat pumps

Measured against models of the same size and duct type, Fuji scores higher on 5 of the 6 ratings. Dynoaire has 22 outdoor models, Fuji has 22 outdoor models. Dynoaire and Fuji have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Dynoaire and Fuji on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Fuji scores higher on 5 of the 6 ratings.
  • Dynoaire
  • Fuji
  • Other ranked manufacturers
DynoaireFuji

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDynoaireFuji
Efficiency index18%median —50%median —
COP at 5°F19%median 1.7558%median 2.00
Capacity retention at 5°F7%median 39%57%median 78%
HSPF221%median 7.545%median 9.0
SEER227%median 14.352%median 20.0
EER241% (higher)median 11.035% (higher)median 11.0
Heating capacity at 5°F9%median 14,000 Btu/h53%median 19,700 Btu/h
Outdoor models2222
AHRI certifications3422

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDynoaireFuji
CEE 2025 Tier 1 (Split ASHP)0%0 models63.6%14 models
CEE 2026 Tier 1 (Split ASHP)0%0 models63.6%14 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models63.6%14 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • Dynoaire
  • Fuji
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDynoaireFuji
Ducted, up to 1.5 tons1 · index —1 · index 49%
Ducted, 2 tons5 · index 8%1 · index 37%
Ducted, 2.5 to 3 tons8 · index 18%2 · index 43%
Ducted, 3.5 to 4.5 tons8 · index 24%2 · index 51%
Non-ducted, up to 1.5 tonsNone9 · index 49%
Non-ducted, 2 tonsNone3 · index 56%
Non-ducted, 2.5 to 3 tonsNone4 · index 55%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDynoaireCold-climate score, best modelFujiCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)50.0(50 is the typical model of its size class)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models qualify · AHRI 218679836
Ducted, 2 tonsNone on this board (0 of 5 models qualify)46.3(50 is the typical model of its size class)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models qualify · AHRI 218679837
Ducted, 2.5 to 3 tonsNone on this board (0 of 8 models qualify)None on this board (0 of 2 models qualify)
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 8 models qualify)72.3(50 is the typical model of its size class)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models qualify · AHRI 218679840
Non-ducted, up to 1.5 tonsNo models in this size class66.2(50 is the typical model of its size class)FM2H18D230U6 of 9 models qualify · AHRI 218668536
Non-ducted, 2 tonsNo models in this size class78.6(50 is the typical model of its size class)FAU24HPI230M22Uwith ductless indoor unit FAU24HPI230M22N2 of 3 models qualify · AHRI 218071064
Non-ducted, 2.5 to 3 tonsNo models in this size class59.7(50 is the typical model of its size class)FM4H42D230U4 of 4 models qualify · AHRI 218668540

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDynoaireAll-around score, best modelFujiAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models have all five ratings)48.7(50 is the typical model of its size class)FAH18HP230Uwith ducted air handler FAH18HP230N1 of 1 models have all five ratings · AHRI 218679836
Ducted, 2 tons8.3(50 is the typical model of its size class)DPHP4024A1FH000A1 of 5 models have all five ratings · AHRI 21881462437.4(50 is the typical model of its size class) (higher)FAH24HP230Uwith ducted air handler FAH24HP230N1 of 1 models have all five ratings · AHRI 218679837
Ducted, 2.5 to 3 tons21.7(50 is the typical model of its size class)DPHP4042A1FH000A3 of 8 models have all five ratings · AHRI 21881462742.8(50 is the typical model of its size class) (higher)FAH30HP230Uwith ducted air handler FAH30HP230N2 of 2 models have all five ratings · AHRI 218679838
Ducted, 3.5 to 4.5 tons25.0(50 is the typical model of its size class)DPHP4048A1FH000A2 of 8 models have all five ratings · AHRI 21881462853.5(50 is the typical model of its size class) (higher)FAH48HP230Uwith ducted air handler FAH48HP230N2 of 2 models have all five ratings · AHRI 218679840
Non-ducted, up to 1.5 tonsNo models in this size class62.0(50 is the typical model of its size class)FM2H18D230U6 of 9 models have all five ratings · AHRI 218668536
Non-ducted, 2 tonsNo models in this size class73.3(50 is the typical model of its size class)FM3H24D230U3 of 3 models have all five ratings · AHRI 218668537
Non-ducted, 2.5 to 3 tonsNo models in this size class67.4(50 is the typical model of its size class)FM4H30D230U4 of 4 models have all five ratings · AHRI 218668538

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDynoaireFuji
COP at 5°Fbeats 41% · 1.90DPHP4060A1FH000ADucted, 3.5 to 4.5 tonsbeats 86% · 2.20FAU18HPI230M22UNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 13% · 42%DPHP4060A1FH000ADucted, 3.5 to 4.5 tonsbeats 81% · 90%FM3H24D230UNon-ducted, 2 tons
HSPF2beats 27% · 7.5DHP5060E1000*Ducted, 3.5 to 4.5 tonsbeats 71% · 10.0FAU24HPI230M22UNon-ducted, 2 tons
SEER2beats 49% · 16.0DPAC4048A1IH000AAlso listed as DPHP6048A1IH000ADucted, 3.5 to 4.5 tonsbeats 81% · 23.0FM3H24D230UNon-ducted, 2 tons
EER2beats 69% · 11.7DHP5048E1000*Ducted, 3.5 to 4.5 tonsbeats 76% · 12.5FM4H30D230UNon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 19% · 16,200 Btu/hDPHP4042A1FH000ADucted, 2.5 to 3 tonsbeats 86% · 14,500 Btu/hFM2H18D230UNon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter