SLOMIN'S vs TRUENORTH heat pumps
Measured against models of the same size and duct type, TRUENORTH scores higher on 6 of the 6 ratings. SLOMIN'S has 10 outdoor models, TRUENORTH has 10 outdoor models. SLOMIN'S and TRUENORTH have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- SLOMIN'S
- TRUENORTH
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | SLOMIN'S | TRUENORTH |
|---|---|---|
| Efficiency index | 36%median — | 53%median — |
| COP at 5°F | 39%median 1.95 | 54%median 2.00 |
| Capacity retention at 5°F | 43%median 71% | 59%median 76% |
| HSPF2 | 37%median 8.5 | 38%median 9.4 |
| SEER2 | 45%median 19.0 | 50%median 20.8 |
| EER2 | 17%median 10.3 | 63%median 12.0 |
| Heating capacity at 5°F | 43%median 22,900 Btu/h | 57%median 19,200 Btu/h |
| Outdoor models | 10 | 10 |
| AHRI certifications | 10 | 22 |
Share of models meeting each standard
| Standard | SLOMIN'S | TRUENORTH |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 80%8 models | 90%9 models |
| CEE 2026 Tier 1 (Split ASHP) | 80%8 models | 90%9 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 10%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 60%6 models | 90%9 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 10%1 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- SLOMIN'S
- TRUENORTH
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | SLOMIN'S | TRUENORTH |
|---|---|---|
| Ducted, 2 tons | 1 · index 37% | 1 · index 55% |
| Ducted, 2.5–3 tons | 1 · index 52% | 2 · index 60% |
| Ducted, 3.5–4.5 tons | 2 · index 41% | 2 · index 68% |
| Ducted, up to 1.5 tons | None | 1 · index 49% |
| Non-ducted, up to 1.5 tons | 2 · index 35% | 4 · index 37% |
| Non-ducted, 2 tons | 1 · index 40% | 2 · index 50% |
| Non-ducted, 2.5–3 tons | 2 · index 28% | 2 · index 68% |
| Non-ducted, 3.5–4.5 tons | 1 · index 18% | 2 · index 52% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | SLOMIN'SCold-climate score, best model | TRUENORTHCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 39.3(50 is the typical model of its size class)WLWHD(18)ND6MO1 of 1 models qualify · AHRI 218593168 |
| Ducted, 2 tons | 42.5(50 is the typical model of its size class)AC2493CZwith ducted air handler AC2493AZ1 of 1 models qualify · AHRI 217563449 | 49.0(50 is the typical model of its size class) (higher)WLWHD(24)ND6MO1 of 1 models qualify · AHRI 218593170 |
| Ducted, 2.5–3 tons | 55.4(50 is the typical model of its size class) (higher)AC2495CZwith ducted air handler AC2495AZ1 of 1 models qualify · AHRI 217563450 | 52.2(50 is the typical model of its size class)WLWHD(36)ND6MO2 of 2 models qualify · AHRI 218593172 |
| Ducted, 3.5–4.5 tons | 43.2(50 is the typical model of its size class)AC2497CZwith ducted air handler AC2497AZ2 of 2 models qualify · AHRI 217563451 | 55.7(50 is the typical model of its size class) (higher)WLWHD(42)ND6MO1 of 2 models qualify · AHRI 218593173 |
| Non-ducted, up to 1.5 tons | 45.3(50 is the typical model of its size class)AC116718CZ2 of 2 models qualify · AHRI 218613084 | 61.4(50 is the typical model of its size class) (higher)WLWHD(18)ND6MO4 of 4 models qualify · AHRI 218593163 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 67.5(50 is the typical model of its size class)WLWHD(24)ND6MO2 of 2 models qualify · AHRI 218593164 |
| Non-ducted, 2.5–3 tons | 34.7(50 is the typical model of its size class)AC116727CZ2 of 2 models qualify · AHRI 218613085 | 77.2(50 is the typical model of its size class) (higher)WLWHD(36)ND6MO2 of 2 models qualify · AHRI 218593166 |
| Non-ducted, 3.5–4.5 tons | None on this board (0 of 1 models qualify) | 66.5(50 is the typical model of its size class)WLWHD(42)ND6MO1 of 2 models qualify · AHRI 218593167 |
All-around best
| Size and duct type | SLOMIN'SAll-around score, best model | TRUENORTHAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 48.6(50 is the typical model of its size class)WLWHD(18)ND6MO1 of 1 models have all five ratings · AHRI 218593168 |
| Ducted, 2 tons | 37.2(50 is the typical model of its size class)AC2493CZwith ducted air handler AC2493AZ1 of 1 models have all five ratings · AHRI 217563449 | 54.7(50 is the typical model of its size class) (higher)WLWHD(24)ND6MO1 of 1 models have all five ratings · AHRI 218593170 |
| Ducted, 2.5–3 tons | 51.6(50 is the typical model of its size class)AC2495CZwith ducted air handler AC2495AZ1 of 1 models have all five ratings · AHRI 217563450 | 61.6(50 is the typical model of its size class) (higher)WLWHD(30)ND6MO2 of 2 models have all five ratings · AHRI 218593171 |
| Ducted, 3.5–4.5 tons | 43.2(50 is the typical model of its size class)AC2497CZwith ducted air handler AC2497AZ2 of 2 models have all five ratings · AHRI 217563451 | 69.1(50 is the typical model of its size class) (higher)WLWHD(42)ND6MO2 of 2 models have all five ratings · AHRI 218593173 |
| Non-ducted, up to 1.5 tons | 36.0(50 is the typical model of its size class)AC116718CZ2 of 2 models have all five ratings · AHRI 218613084 | 52.7(50 is the typical model of its size class) (higher)WLWHD(18)ND6MO4 of 4 models have all five ratings · AHRI 218593163 |
| Non-ducted, 2 tons | 40.4(50 is the typical model of its size class)AC1167Z24with ductless indoor unit AC1167Z241 of 1 models have all five ratings · AHRI 218613089 | 67.6(50 is the typical model of its size class) (higher)WLWHD(24)ND6MO2 of 2 models have all five ratings · AHRI 218593164 |
| Non-ducted, 2.5–3 tons | 31.0(50 is the typical model of its size class)AC116727CZ2 of 2 models have all five ratings · AHRI 218613085 | 70.5(50 is the typical model of its size class) (higher)WLWHD(30)ND6MO2 of 2 models have all five ratings · AHRI 218593165 |
| Non-ducted, 3.5–4.5 tons | 17.9(50 is the typical model of its size class)AC116742CZ1 of 1 models have all five ratings · AHRI 218613087 | 67.7(50 is the typical model of its size class) (higher)WLWHD(42)ND6MO2 of 2 models have all five ratings · AHRI 218593167 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | SLOMIN'S | TRUENORTH |
|---|---|---|
| COP at 5°F | beats 71% · 2.10AC1167Z24Non-ducted, 2 tons | beats 96% · 2.20WLWHD(60)ND6MONon-ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 61% · 80%AC116718CZNon-ducted, up to 1.5 tons | beats 81% · 100%WLWHD(36)ND6MONon-ducted, 2.5–3 tons |
| HSPF2 | beats 65% · 9.0AC2495CZDucted, 2.5–3 tons | beats 69% · 10.0WLWHD(24)ND6MONon-ducted, 2 tons |
| SEER2 | beats 82% · 19.0AC2495CZDucted, 2.5–3 tons | beats 85% · 19.0WLWHD(60)ND6MODucted, 3.5–4.5 tons |
| EER2 | beats 30% · 11.2AC1167Z12Non-ducted, up to 1.5 tons | beats 94% · 13.0WLWHD(42)ND6MONon-ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 88% · 16,000 Btu/hAC116718CZNon-ducted, up to 1.5 tons | beats 86% · 36,000 Btu/hWLWHD(36)ND6MONon-ducted, 2.5–3 tons |