- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
2,834 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 24765A6V8X48A1AMERICAN STANDARDwith indoor coil D(A,C,E)48B4J+TDR and furnace L8V1C100U5VSB+LRP | Trane | 3.5 tons42,500 Btu/h · Ducted | 2.87 | 93% | 8.5 | 18.0 | 10.5 | 42,500 | CEE 25CEE 26XcelES CC | 410 | 217117338 |
| 24775A6V8X60A1AMERICAN STANDARDwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2C080U5VSB+LRP | Trane | 4 tons50,500 Btu/h · Ducted | 2.71 | 88% | 8.5 | 18.0 | 9.8 | 49,500 | CEE 25CEE 26XcelES CC | 271 | 217117455 |
| 24785DCZ5042A1TRANE · 5DCZ5 | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.00 | 51% | 7.2 | 15.2 | 11.5 | 20,000 | None | 2 | 216574914 |
| 24795DCZ5048A1TRANE · 5DCZ5 | Trane | 4 tons47,000 Btu/h · Ducted | 2.00 | 52% | 8.1 | 15.2 | 11.5 | 22,000 | None | 2 | 216574916 |
| 24805DCZ5048A1090BTRANE · 5DCZ5 | Trane | 4 tons47,000 Btu/h · Ducted | 2.13 | 52% | 7.5 | 15.2 | 11.2 | 22,000 | None | 2 | 218696853 |
| 24815HCL5060A1TRANE · 5HCL5 Cold Climatewith ducted air handler 5TEM5D06AC41 | Trane | 4 tons48,000 Btu/h · Ducted | 1.85 | 88% | 9.4 | 17.0 | 10.8 | 42,000 | CEE 25CEE 26Xcel | 4 | 216772257 |
| 24825HCL5060B1TRANE · F Serieswith ducted air handler 5DXCD008AC3 | Trane | 4 tons47,000 Btu/h · Ducted | 1.85 | 98% | 8.8 | 16.0 | 11.0 | 47,000 | CEE 25CEE 26XcelES CC | 20 | 217500298 |
| 24835HPL5048A1AMERICAN STANDARDwith ducted air handler L(E,G)M60DJ | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.03 | 104% | 7.8 | 15.2 | 11.2 | 49,500 | CEE 25CEE 26XcelES CC | 360 | 217106838 |
| 24845HPL5048A1*TRANEwith ducted air handler 5PXCBD06AS3+P0V0B000M40SD | Trane | 3.5 tons41,000 Btu/h · Ducted | 1.80 | 82% | 8.1 | 15.2 | 10.8 | 37,000 | Xcel | 18 | 218080537 |
| 24855HPL5048A1000AATRANE · 5HPL5with ducted air handler 5TEM6D06AV41+TDR | Trane | 4 tons46,000 Btu/h · Ducted | 1.75 | 79% | 8.1 | 16.0 | 11.7 | 38,000 | CEE 25CEE 26XcelES CC | 14 | 216374488 |
| 24865HPL5060A1AMERICAN STANDARDwith ducted air handler L(E,G)M60DJ | Trane | 4 tons47,000 Btu/h · Ducted | 1.89 | 102% | 7.5 | 15.2 | 9.0 | 54,000 | Xcel | 17 | 217106839 |
| 24875TCV0X60A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,500 Btu/h · Ducted | 2.05 | 87% | 9.4 | 19.2 | 11.5 | 48,000 | CEE 25CEE 26XcelES CC | 30 | 218792279 |
| 24885TCV0X61A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,000 Btu/h · Ducted | 2.22 | 100% | 10.0 | 18.0 | 11.5 | 55,500 | CEE 25CEE 26CEE AdvXcelDOEES CC | 22 | 218792281 |
| 24895TWA4042A3TRANEwith indoor coil DH60T4J and furnace *UHMC100CCV4 | Trane | 3.5 tons39,500 Btu/h · Ducted | 2.19 | 60% | 7.5 | 15.2 | 12.0 | 23,600 | CEE 25 | 459 | 217209472 |
| 24905TWA4042A4TRANEwith indoor coil DH60T4J and furnace *UHMC100CCV4 | Trane | 3.5 tons39,500 Btu/h · Ducted | 2.19 | 60% | 7.5 | 15.2 | 12.0 | 23,600 | CEE 25 | 440 | 217209589 |
| 24915TWA4048A3TRANEwith indoor coil DH60T4J and furnace S9X1D120U5PSB | Trane | 4 tons45,500 Btu/h · Ducted | 2.33 | 64% | 8.1 | 15.5 | 12.0 | 28,600 | CEE 25CEE 26 | 592 | 217209817 |
| 24925TWA4048A4TRANEwith indoor coil DH60T4J and furnace S9X1D120U5PSB | Trane | 4 tons45,500 Btu/h · Ducted | 2.33 | 64% | 8.1 | 15.5 | 12.0 | 28,600 | CEE 25CEE 26 | 589 | 217209944 |
| 24935TWA4060A3TRANEwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4.5 tons56,000 Btu/h · Ducted | 2.22 | 51% | 7.8 | 15.2 | 12.0 | 26,600 | None | 247 | 218788202 |
| 24945TWA4060A4TRANEwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4.5 tons56,000 Btu/h · Ducted | 2.22 | 51% | 7.8 | 15.2 | 12.0 | 26,600 | None | 242 | 218788204 |
| 24955TWR4048A1TRANEwith indoor coil DH60T4J and furnace S8V2B060M4PCB | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.75 | 69% | 7.5 | 14.3 | 11.7 | 27,800 | None | 865 | 216953121 |
| 24965TWR4060A1TRANEwith indoor coil DH60T4J and furnace S8X1D120M5PSC | Trane | 4.5 tons52,000 Btu/h · Ducted | 3.09 | 70% | 7.5 | 14.3 | 11.0 | 34,400 | None | 428 | 216953201 |
| 24975TWR5048A1TRANEwith indoor coil DH60T4J and furnace S9V2D120D5PSC | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.78 | 67% | 7.5 | 15.5 | 12.0 | 26,800 | CEE 25CEE 26 | 1,324 | 216952867 |
| 24985TWR5060A1TRANEwith indoor coil DH60T4J and furnace L8V1C100U5VSB | Trane | 4.5 tons52,500 Btu/h · Ducted | 3.06 | 70% | 8.1 | 15.5 | 11.7 | 35,000 | Xcel | 651 | 216952883 |
| 24995TWR6042A1TRANEwith ducted air handler 98-8810+TXV+RDS+TDR+E30B5D | Trane | 3.5 tons39,000 Btu/h · Ducted | 2.36 | 51% | 7.8 | 15.2 | 12.0 | 18,500 | CEE 25CEE 26 | 464 | 218748029 |
| 25005TWR6048A1TRANEwith ducted air handler 98-8810+TXV+RDS+TDR+E30B5D | Trane | 3.5 tons43,000 Btu/h · Ducted | 2.46 | 52% | 7.8 | 15.2 | 12.0 | 21,200 | CEE 25CEE 26 | 497 | 218748027 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,834 models; narrow the filters for the rest.