Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

2,834 models

Sorted by manufacturer and model.
Page 107 of 114
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
2651D5CUHAH48AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5B48L0CViessmann4 tons47,000 Btu/h · Ducted1.7589%8.514.38.544,500None1217753139
2652D5CUHAH60AAKViessmann · D5C Serieswith ducted air handler D5FUHAH60XAKViessmann4.5 tons54,000 Btu/h · Ducted1.9098%9.517.512.054,000CEE 25CEE 26XcelES CC6217178771
2653D5CUHAH60AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5B60L0DViessmann4.5 tons54,500 Btu/h · Ducted1.8488%9.016.010.052,000CEE 25CEE 26Xcel1217753140
2654D5CURAH48AAKViessmann · D5C Serieswith ducted air handler D5FUAAH48XAKViessmann4 tons48,000 Btu/h · Ducted1.8579%8.516.010.038,000CEE 25CEE 26XcelES CC4217178779
2655D5CURAH60AAKVIESSMANN · Crossover heat pumpwith ducted air handler FTMA5B60L0DViessmann4.5 tons52,000 Btu/h · Ducted1.8664%7.514.59.038,500ES CC6217753133
2656D5CURAH60AAK+KSAIC0701230VIESSMANN · Crossover heat pumpwith ducted air handler FTMA5B60L0DViessmann4.5 tons52,000 Btu/h · Ducted1.8664%7.514.59.038,500None1218475440
2657VHP-UCHA-48HDCTVillarawith ducted air handler VAH-UCHA-48HDCVillara4 tons48,000 Btu/h · Ducted2.2073%9.818.511.035,000CEE 25CEE 26Xcel1217081898
2658VHP-UCHA-60HDCTVillara · T Serieswith ducted air handler VAH-UCHA-60HDCVillara4.5 tons54,000 Btu/h · Ducted2.2071%9.016.09.238,500None1217001205
2659VHP-UCA-48HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-48HDC-AVillaTherm4 tons48,000 Btu/h · Ducted2.2073%9.818.511.035,000CEE 25CEE 26XcelES CC1218030991
2660VHP-UCA-60HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-60HDC-AVillaTherm4.5 tons54,000 Btu/h · Ducted2.2071%9.017.09.538,500ES CC1218030992
2661VHP-UCHA-48HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-48HDCSN4VillaTherm4 tons48,000 Btu/h · Ducted2.2575%9.817.511.036,000CEE 25CEE 26Xcel1217753630
2662VHP-UCHA-48HDCTVillaTherm · T Serieswith ducted air handler VAH-UCHA-48HDCVillaTherm4 tons48,000 Btu/h · Ducted2.2073%9.818.511.035,000CEE 25CEE 26XcelES CC1217155425
2663VHP-UCHA-48HDCT-AVillaTherm · T2 Serieswith ducted air handler VAH-UCHA-48HDC-AVillaTherm4 tons48,000 Btu/h · Ducted2.2073%9.818.511.035,000CEE 25CEE 26XcelES CC5218046442
2664VHP-UCHA-60HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-60HDCSN4VillaTherm4.5 tons54,000 Btu/h · Ducted2.2074%9.016.710.040,000CEE 25CEE 26Xcel1217753631
2665VHP-UCHA-60HDCTVillaTherm · T Serieswith ducted air handler VAH-UCHA-60HDCVillaTherm4.5 tons54,000 Btu/h · Ducted2.2071%9.016.09.238,500ES CC1217155423
2666VHP-UCHA-60HDCT-AVillaTherm · T2 Serieswith ducted air handler VAH-UCHA-60HDC-AVillaTherm4.5 tons54,000 Btu/h · Ducted2.2071%9.017.09.538,500CEE 25CEE 26XcelES CC5218046443
2667VHPSD-UCHA-48HDCSN*VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-48SHDCALN2VillaTherm4 tons48,000 Btu/h · Ducted2.2575%9.817.511.036,000CEE 25CEE 26XcelES CC1218731836
2668VHPSD-UCHA-48HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAHSD-UCHA-48HDCSN4VillaTherm4 tons48,000 Btu/h · Ducted2.2575%9.817.511.036,000CEE 25CEE 26XcelES CC3217889248
2669VHPSD-UCHA-60HDCSN*VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-60SHDCALN2VillaTherm4.5 tons54,000 Btu/h · Ducted2.2074%9.016.710.040,000CEE 25CEE 26XcelES CC1218731837
2670VHPSD-UCHA-60HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAHSD-UCHA-60HDCSN4VillaTherm4.5 tons54,000 Btu/h · Ducted2.2074%9.016.710.040,000CEE 25CEE 26XcelES CC3217889249
2671VUH48-VA6BA(O)VINO · VSHPwith ducted air handler VUH48-VA6BA(I)VINO4 tons48,000 Btu/h · Ducted2.1093%11.020.012.044,500CEE 25CEE 26XcelES CC1218597507
2672VUH60-VA6BA(O)VINO · VSHPwith ducted air handler VUH60-VA6BA(I)VINO4.5 tons52,500 Btu/h · Ducted2.1682%10.819.611.544,500CEE 25CEE 26XcelES CC1218361279
2673UCHA-48HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-48HDCN4VKIN4 tons48,000 Btu/h · Ducted2.2575%9.817.511.036,000CEE 25CEE 26XcelES CC3218385962
2674UCHA-48HDCTVKIN · AHUwith ducted air handler UCHA-48HDCVKIN4 tons48,000 Btu/h · Ducted2.2073%9.818.511.035,000CEE 25CEE 26XcelES CC1218385957
2675UCHA-60HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-60HDCN4VKIN4.5 tons54,000 Btu/h · Ducted2.2074%9.016.710.040,000CEE 25CEE 26XcelES CC3218385963

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,834 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter