Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

13,619 models

Sorted by manufacturer and model.
Page 11 of 545
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
251H5H3V48*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CSU1002120AACIQ3.5 tons43,500 Btu/h · Ducted2.0076%9.520.510.536,600CEE 25CEE 26XcelES CC332216635479
252H5H3V60*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716BACIQ4.5 tons56,000 Btu/h · Ducted2.1075%8.518.011.045,500CEE 25CEE 26XcelES CC180216635247
253H5H6S24*K*AAA*ACIQ · MAINLINE 16 SEER2 HPwith ducted air handler FM(C,U)5X30**ALACIQ2 tons23,400 Btu/h · Ducted2.0550%8.014.511.711,800None2216625540
254N5H5S18*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler FMA5X24**ALACIQ1.5 tons17,400 Btu/h · Ducted2.1046%8.015.512.58,200None373216630607
255N5H5S24*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler FMA5X30**ALACIQ2 tons24,000 Btu/h · Ducted2.2649%8.516.513.011,600CEE 25CEE 26805216630615
256N5H5S30*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler FMA5X30**ALACIQ2.5 tons29,000 Btu/h · Ducted2.2648%8.115.212.513,900None352216630619
257N5H5S36*H*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler FMA5X36**ALACIQ3 tons35,000 Btu/h · Ducted2.2048%7.815.512.517,100None95217736056
258N5H5S36*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith indoor coil ESH5X48M12A and furnace *97VTN1002122AACIQ3 tons36,000 Btu/h · Ducted2.2048%7.514.512.017,400None729215817808
259N5H5S36*L*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*48L*CACIQ3 tons36,800 Btu/h · Ducted2.2048%8.016.013.017,400CEE 25101217736146
260N5H5S42*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*60L*DACIQ3.5 tons42,500 Btu/h · Ducted2.2649%7.815.211.719,900None144216629131
261N5H5S48*H*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler FTMA5B60L0DACIQ4 tons47,500 Btu/h · Ducted2.2549%7.815.512.023,600None13217735979
262N5H5S48*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*60L*DACIQ4 tons46,500 Btu/h · Ducted2.3052%7.815.212.524,400None131216629117
263N5H5S48*L*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*60L*DACIQ4 tons48,500 Btu/h · Ducted2.2550%7.815.212.024,400None11217735987
264N5H5S48*S*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*60L*DACIQ4 tons48,500 Btu/h · Ducted2.2050%7.815.212.024,400None13217735988
265N5H5S60*H*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*60L*DACIQ5 tons57,500 Btu/h · Ducted2.1052%7.514.512.028,600None3217736308
266N5H5S60*K*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler FTMA5B60L0DACIQ5 tons57,000 Btu/h · Ducted2.1852%7.815.212.528,600None3216630633
267N5H5S60*L*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*60L*DACIQ5 tons57,500 Btu/h · Ducted2.1052%7.514.512.028,600None3217736318
268N5H5S60*S*AAA*ACIQ · PERFORMANCE 16 SEER2 HPwith ducted air handler F5MA5*60L*DACIQ5 tons57,500 Btu/h · Ducted2.1052%7.514.512.028,600None3217736323
269N5H8T24*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith indoor coil EA*5X37M21A and furnace *80MSU0401712AACIQ2 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 251,019216632609
270N5H8T36*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith ducted air handler FTMA5B60L0DACIQ3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 26791216631656
271N5H8T48*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith ducted air handler FTMA5B60L0DACIQ4 tons48,500 Btu/h · Ducted2.3251%8.118.013.524,600CEE 25CEE 26575215561906
272N5H8T60*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith indoor coil EVM5X61M24A and furnace *80CTL1352422BACIQ4.5 tons56,000 Btu/h · Ducted2.3452%8.515.511.531,400CEE 25CEE 26419216631510
273N5H9V24*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B36L0CACIQ2 tons23,400 Btu/h · Ducted2.0287%10.018.514.021,200CEE 25CEE 26XcelES CC1,100218019289
274N5H9V36*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler F5MA5*36L*BACIQ3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC836218020881
275N5H9V48*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler FTMA5B60L0DACIQ4 tons46,000 Btu/h · Ducted2.3275%10.019.012.536,000CEE 25CEE 26XcelES CC553218020919