Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

1,941 models

Sorted by manufacturer and model.
Page 13 of 78
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
301248TAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 83*SB48060M17Carrier2 tons23,000 Btu/h · Ducted2.9051%8.117.513.012,900CEE 25CEE 261,821217676875
302249VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler FT5AN(B,X)C36LCarrier2 tons23,400 Btu/h · Ducted2.0287%10.018.514.021,200CEE 25CEE 26XcelES CC1,165217950372
30327SCA530A**30*CARRIERwith ducted air handler PE(S,T)35JCarrier2 tons26,800 Btu/h · Ducted2.6258%7.515.211.716,600None1,438217006642
30427SPA624A**30*CARRIERwith ducted air handler PE(S,T)29JCarrier2 tons21,000 Btu/h · Ducted2.6465%7.515.211.714,700CEE 25CEE 262,974217006647
30527SPA630A**30*CARRIERwith ducted air handler PE(S,T)35JCarrier2 tons26,800 Btu/h · Ducted2.6258%7.515.211.716,600None1,227217006649
30627TPA824A**30*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 58SU*B040M17**12Carrier2 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 251,782215647843
30727VNA024A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNXB24L*+UICarrier2 tons23,400 Btu/h · Ducted2.0470%9.017.510.516,600CEE 25CEE 26XcelES CC438215662625
30827VNA324A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 58CU*B040C17**12Carrier2 tons23,200 Btu/h · Ducted2.1081%9.522.013.022,200CEE 25CEE 26XcelES CC449217624599
30927VPA924A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler FT5AN(B,X)C36LCarrier2 tons23,400 Btu/h · Ducted2.0287%10.018.514.021,200CEE 25CEE 26XcelES CC1,250217934991
310290VAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 88*TB66135C24Carrier2 tons21,800 Btu/h · Ducted2.7983%8.516.09.819,800CEE 25CEE 26XcelES CC753217676739
311293VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 83*CB36040C17Carrier2 tons23,200 Btu/h · Ducted2.1081%9.522.013.022,200CEE 25CEE 26XcelES CC445217624600
31237MAHAQ24AA3CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ24XA3Carrier2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.213.024,200CEE 25CEE 26XcelES CC22215323746
31337MARAQ24AA3CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ24XA3Carrier2 tons24,000 Btu/h · Ducted and non-ducted2.5478%11.723.114.019,600CEE 25CEE 26XcelES CC22215323752
31437MGHAQ24DA3BRYANT · 37M SeriesCarrier2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.024.013.025,000CEE 25CEE 26XcelES CC12215357109
31537MGRAQ24DA3BRYANT · 37M SeriesCarrier2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0072%9.525.013.518,000CEE 25CEE 26XcelES CC12215357137
31637MHRAQ24AA3CARRIERwith ductless indoor unit 45MHHAQ24XC3Carrier2 tons24,000 Btu/h · Non-ducted2.1171%9.018.59.517,000Xcel4215413176
31737MTRAQ27DA3CARRIER · 37M SeriesCarrier2 tons26,400 Btu/h · Non-ducted2.0070%8.518.510.518,600CEE 25CEE 26XcelES CC4216765584
31837MUHAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons22,000 Btu/h · Ducted3.0698%8.515.59.820,800CEE 25CEE 26XcelES CC4,679218331062
31937MUHAQ24AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FJ5AN*B30LCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.011.019,000CEE 25CEE 26XcelES CC2,935218473449
32037MUHAQ24AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJCarrier2 tons23,200 Btu/h · Ducted2.6984%9.517.511.018,100CEE 25CEE 26XcelES CC2,456218330895
32137MURAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons23,400 Btu/h · Ducted3.1687%8.514.39.021,200CEE 25CEE 26XcelES CC3,264218331338
32237MURAQ24AA3+KSAIC0701230CARRIER · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**ALCarrier2 tons24,800 Btu/h · Ducted2.1482%9.516.010.019,600CEE 25CEE 26XcelES CC1,806218475082
32337MVRAQ24AA3CARRIER · D5M Serieswith ductless indoor unit D5MVHAQ24XA3Carrier2 tons24,000 Btu/h · Non-ducted2.0171%8.517.09.017,100XcelES CC8215323841
32438AMBIQ24AA3CARRIERwith ductless indoor unit 40AMBIQ24XA3Carrier2 tons21,000 Btu/h · Non-ducted——9.018.59.4—None1217478334
32548NR*B24***30*CARRIER · Performance HPCarrier2 tons22,200 Btu/h · Ducted1.6036%7.215.211.58,400None1217154369

Download CSV of the matching modelsAll 1,941 matching models, every page, in this order.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter