Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 301248TAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 83*SB48060M17 | Carrier | 2 tons23,000 Btu/h · Ducted | 2.90 | 51% | 8.1 | 17.5 | 13.0 | 12,900 | CEE 25CEE 26 | 1,821 | 217676875 |
| 302249VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler FT5AN(B,X)C36L | Carrier | 2 tons23,400 Btu/h · Ducted | 2.02 | 87% | 10.0 | 18.5 | 14.0 | 21,200 | CEE 25CEE 26XcelES CC | 1,165 | 217950372 |
| 30327SCA530A**30*CARRIERwith ducted air handler PE(S,T)35J | Carrier | 2 tons26,800 Btu/h · Ducted | 2.62 | 58% | 7.5 | 15.2 | 11.7 | 16,600 | None | 1,438 | 217006642 |
| 30427SPA624A**30*CARRIERwith ducted air handler PE(S,T)29J | Carrier | 2 tons21,000 Btu/h · Ducted | 2.64 | 65% | 7.5 | 15.2 | 11.7 | 14,700 | CEE 25CEE 26 | 2,974 | 217006647 |
| 30527SPA630A**30*CARRIERwith ducted air handler PE(S,T)35J | Carrier | 2 tons26,800 Btu/h · Ducted | 2.62 | 58% | 7.5 | 15.2 | 11.7 | 16,600 | None | 1,227 | 217006649 |
| 30627TPA824A**30*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 58SU*B040M17**12 | Carrier | 2 tons23,800 Btu/h · Ducted | 2.24 | 45% | 8.5 | 18.0 | 13.0 | 11,100 | CEE 25 | 1,782 | 215647843 |
| 30727VNA024A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNXB24L*+UI | Carrier | 2 tons23,400 Btu/h · Ducted | 2.04 | 70% | 9.0 | 17.5 | 10.5 | 16,600 | CEE 25CEE 26XcelES CC | 438 | 215662625 |
| 30827VNA324A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 58CU*B040C17**12 | Carrier | 2 tons23,200 Btu/h · Ducted | 2.10 | 81% | 9.5 | 22.0 | 13.0 | 22,200 | CEE 25CEE 26XcelES CC | 449 | 217624599 |
| 30927VPA924A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler FT5AN(B,X)C36L | Carrier | 2 tons23,400 Btu/h · Ducted | 2.02 | 87% | 10.0 | 18.5 | 14.0 | 21,200 | CEE 25CEE 26XcelES CC | 1,250 | 217934991 |
| 310290VAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 88*TB66135C24 | Carrier | 2 tons21,800 Btu/h · Ducted | 2.79 | 83% | 8.5 | 16.0 | 9.8 | 19,800 | CEE 25CEE 26XcelES CC | 753 | 217676739 |
| 311293VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 83*CB36040C17 | Carrier | 2 tons23,200 Btu/h · Ducted | 2.10 | 81% | 9.5 | 22.0 | 13.0 | 22,200 | CEE 25CEE 26XcelES CC | 445 | 217624600 |
| 31237MAHAQ24AA3CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ24XA3 | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.34 | 83% | 13.5 | 21.2 | 13.0 | 24,200 | CEE 25CEE 26XcelES CC | 22 | 215323746 |
| 31337MARAQ24AA3CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ24XA3 | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.54 | 78% | 11.7 | 23.1 | 14.0 | 19,600 | CEE 25CEE 26XcelES CC | 22 | 215323752 |
| 31437MGHAQ24DA3BRYANT · 37M Series | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.0 | 24.0 | 13.0 | 25,000 | CEE 25CEE 26XcelES CC | 12 | 215357109 |
| 31537MGRAQ24DA3BRYANT · 37M Series | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 72% | 9.5 | 25.0 | 13.5 | 18,000 | CEE 25CEE 26XcelES CC | 12 | 215357137 |
| 31637MHRAQ24AA3CARRIERwith ductless indoor unit 45MHHAQ24XC3 | Carrier | 2 tons24,000 Btu/h · Non-ducted | 2.11 | 71% | 9.0 | 18.5 | 9.5 | 17,000 | Xcel | 4 | 215413176 |
| 31737MTRAQ27DA3CARRIER · 37M Series | Carrier | 2 tons26,400 Btu/h · Non-ducted | 2.00 | 70% | 8.5 | 18.5 | 10.5 | 18,600 | CEE 25CEE 26XcelES CC | 4 | 216765584 |
| 31837MUHAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22 | Carrier | 2 tons22,000 Btu/h · Ducted | 3.06 | 98% | 8.5 | 15.5 | 9.8 | 20,800 | CEE 25CEE 26XcelES CC | 4,679 | 218331062 |
| 31937MUHAQ24AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FJ5AN*B30L | Carrier | 2 tons24,200 Btu/h · Ducted | 2.06 | 83% | 9.0 | 16.0 | 11.0 | 19,000 | CEE 25CEE 26XcelES CC | 2,935 | 218473449 |
| 32037MUHAQ24AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJ | Carrier | 2 tons23,200 Btu/h · Ducted | 2.69 | 84% | 9.5 | 17.5 | 11.0 | 18,100 | CEE 25CEE 26XcelES CC | 2,456 | 218330895 |
| 32137MURAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22 | Carrier | 2 tons23,400 Btu/h · Ducted | 3.16 | 87% | 8.5 | 14.3 | 9.0 | 21,200 | CEE 25CEE 26XcelES CC | 3,264 | 218331338 |
| 32237MURAQ24AA3+KSAIC0701230CARRIER · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 2 tons24,800 Btu/h · Ducted | 2.14 | 82% | 9.5 | 16.0 | 10.0 | 19,600 | CEE 25CEE 26XcelES CC | 1,806 | 218475082 |
| 32337MVRAQ24AA3CARRIER · D5M Serieswith ductless indoor unit D5MVHAQ24XA3 | Carrier | 2 tons24,000 Btu/h · Non-ducted | 2.01 | 71% | 8.5 | 17.0 | 9.0 | 17,100 | XcelES CC | 8 | 215323841 |
| 32438AMBIQ24AA3CARRIERwith ductless indoor unit 40AMBIQ24XA3 | Carrier | 2 tons21,000 Btu/h · Non-ducted | — | — | 9.0 | 18.5 | 9.4 | — | None | 1 | 217478334 |
| 32548NR*B24***30*CARRIER · Performance HP | Carrier | 2 tons22,200 Btu/h · Ducted | 1.60 | 36% | 7.2 | 15.2 | 11.5 | 8,400 | None | 1 | 217154369 |