- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
7,174 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 3776QOS09H2BM5AInnovair · Q4with ductless indoor unit QHW09H2UZRA | Innovair | 1 ton9,000 Btu/h · Non-ducted | 2.09 | 100% | 11.0 | 25.0 | 13.7 | 9,000 | CEE 25CEE 26XcelES CC | 2 | 215493760 |
| 3777QOS12H1BM0AInnovair · Q4with ductless indoor unit QHW12H1UZRA | Innovair | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 77% | 9.5 | 22.0 | 12.3 | 9,200 | CEE 25CEE 26XcelES CC | 1 | 216445290 |
| 3778QOS12H1BM5AInnovair · Q4with ductless indoor unit QHW12H1UZRA | Innovair | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 77% | 9.5 | 22.0 | 12.3 | 9,200 | CEE 25CEE 26XcelES CC | 2 | 215493759 |
| 3779QOS12H2BH0AInnovair · Q4+with ducted air handler QDL12H2BHWA | Innovair | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.80 | 100% | 9.5 | 19.5 | 11.7 | 12,000 | CEE 25CEE 26XcelES CC | 4 | 216626159 |
| 3780QOS12H2BM0AInnovair · Q4with ductless indoor unit QHW12H2UZRA | Innovair | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 92% | 10.0 | 23.0 | 12.3 | 11,000 | CEE 25CEE 26XcelES CC | 2 | 216445278 |
| 3781QOS12H2BM5AInnovair · Q4with ductless indoor unit QHW12H2UZRA | Innovair | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 92% | 10.0 | 23.0 | 12.3 | 11,000 | CEE 25CEE 26XcelES CC | 2 | 215493761 |
| 3782QOS18H2BH0AInnovair · Q4+with ductless indoor unit QCS18H2BHRA | Innovair | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.00 | 100% | 10.0 | 20.0 | 12.0 | 18,000 | CEE 25CEE 26XcelES CC | 4 | 216626162 |
| 3783QOS18H2BM0AInnovair · Q4with ductless indoor unit QHW18H2UZRA | Innovair | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 100% | 10.0 | 21.0 | 13.0 | 18,000 | CEE 25CEE 26XcelES CC | 2 | 216445279 |
| 3784QOS18H2BM5AInnovair · Q4with ductless indoor unit QHW18H2UZRA | Innovair | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 100% | 10.0 | 21.0 | 13.0 | 18,000 | CEE 25CEE 26XcelES CC | 2 | 215493762 |
| 3785QOS18H2XE5AInnovair · Q32with ductless indoor unit QHW18H2UZRB | Innovair | 1.5 tons18,000 Btu/h · Non-ducted | 2.53 | 74% | 9.8 | 20.0 | 12.0 | 13,400 | CEE 25CEE 26Xcel | 2 | 218030995 |
| 3786QOS24H2BH0AInnovair · Q4+with ductless indoor unit QCS24H2BHRA | Innovair | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.00 | 100% | 10.5 | 20.0 | 12.0 | 24,000 | CEE 25CEE 26XcelES CC | 4 | 216626163 |
| 3787QOS24H2BM0AInnovair · Q4+with ductless indoor unit QHW24H2UZRB | Innovair | 2 tons24,000 Btu/h · Non-ducted | 2.00 | 80% | 9.5 | 22.5 | 12.3 | 19,200 | CEE 25CEE 26XcelES CC | 2 | 218083329 |
| 3788QOS24H2BM5AInnovair · Q4with ductless indoor unit QHW24H2UZRB | Innovair | 2 tons24,000 Btu/h · Non-ducted | 2.00 | 80% | 9.5 | 22.5 | 12.3 | 19,200 | CEE 25CEE 26XcelES CC | 2 | 218031000 |
| 3789QOS24H2XE5AInnovair · Q32with ductless indoor unit QHW24H2UZRB | Innovair | 2 tons24,000 Btu/h · Non-ducted | 1.98 | 76% | 9.0 | 19.5 | 10.6 | 18,200 | CEE 25CEE 26Xcel | 2 | 218030996 |
| 3790QOS36H2BH0AInnovair · Q4+with ducted air handler QDH36H2BHWA | Innovair | 3 tons33,000 Btu/h · Ducted and non-ducted | 2.00 | 100% | 9.0 | 18.5 | 11.7 | 36,000 | CEE 25CEE 26XcelES CC | 2 | 216699604 |
| 3791SHV18H2BAINNOVAIR · SHV Serieswith ducted air handler SAV18BDU | Innovair | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | 12.5 | 18,600 | CEE 25CEE 26CEE AdvXcelDOEES CC | 38 | 217966389 |
| 3792SHV24H2BAINNOVAIRwith ducted air handler D(A,C,E)24A2J+TDR | Innovair | 1.5 tons20,000 Btu/h · Ducted | 2.46 | 84% | 9.0 | 16.0 | 10.0 | 19,700 | CEE 25CEE 26XcelES CC | 56 | 217562039 |
| 3793SHV30H2BAINNOVAIRwith ducted air handler D(A,C,E)36C2J+TDR | Innovair | 2.5 tons27,000 Btu/h · Ducted | 2.52 | 80% | 8.5 | 14.8 | 9.0 | 23,800 | CEE 25CEE 26XcelES CC | 67 | 217562029 |
| 3794SHV36H2BAINNOVAIR · SAV Serieswith ducted air handler SAV36BDA | Innovair | 3 tons36,000 Btu/h · Ducted | 1.85 | 86% | 8.2 | 16.5 | 10.0 | 32,000 | XcelES CC | 2 | 215798837 |
| 3795SHV36H2BBINNOVAIRwith ducted air handler D(A,C,E)36C2J+TDR | Innovair | 2.5 tons29,600 Btu/h · Ducted | 2.15 | 78% | 8.1 | 14.3 | 10.0 | 27,000 | CEE 25CEE 26XcelES CC | 55 | 217562031 |
| 3796SHV48H2BAINNOVAIRwith ducted air handler D(A,C,E)60C2J+TDR | Innovair | 3.5 tons41,000 Btu/h · Ducted | 2.49 | 73% | 8.1 | 14.3 | 9.0 | 33,800 | CEE 25CEE 26XcelES CC | 36 | 217562033 |
| 3797SHV60H2BAINNOVAIRwith ducted air handler D(A,C,E)60C2J+TDR | Innovair | 4 tons47,000 Btu/h · Ducted | 2.52 | 80% | 8.5 | 15.2 | 9.0 | 44,500 | CEE 25CEE 26XcelES CC | 33 | 217562040 |
| 3798SOV24H2BAINNOVAIRwith ducted air handler D(A,C,E)24A2J+TDR | Innovair | 2 tons21,200 Btu/h · Ducted | 2.81 | 79% | 8.1 | 15.5 | 9.0 | 19,500 | CEE 25CEE 26XcelES CC | 61 | 217562034 |
| 3799SOV36H2BAINNOVAIRwith ducted air handler D(A,C,E)36C2J+TDR | Innovair | 2.5 tons31,400 Btu/h · Ducted | 2.59 | 72% | 8.1 | 14.3 | 9.0 | 25,400 | CEE 25CEE 26XcelES CC | 67 | 217550264 |
| 3800SOV48H2BAINNOVAIRwith indoor coil MAC60H2428B and furnace MGV96U120D5C | Innovair | 4 tons45,000 Btu/h · Ducted | 1.90 | 89% | 9.1 | 15.0 | 9.8 | 41,000 | CEE 25CEE 26XcelES CC | 61 | 218859555 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,174 models; narrow the filters for the rest.