Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

2,722 models

Sorted by manufacturer and model.
Page 16 of 109
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
376(C,H,T)5H3V36*K*AAA*KENMORE · Deluxe 23 VS Heat Pumpwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122BCarrier3 tons35,600 Btu/h · Ducted2.1475%9.022.012.528,400CEE 25CEE 26XcelES CC614215936672
377(C,H,T)5H6S30*K*AAA*KENMORE · MAINLINE 16 SEER2 HPwith indoor coil ESH5X30M12A and furnace *80CTL1102120ACarrier2.5 tons28,400 Btu/h · Ducted2.2646%7.815.512.513,000None472214167858
378(C,H,T)5H6S31*K*AAA*KENMORE · MAINLINE 16 SEER2 HPwith indoor coil EA*5X37M21A*+WALLCON and furnace *80CSU0401712BCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 25653217717191
379(C,H,T)5H6S36*K*AAA*KENMORE · MAINLINE 16 SEER2 HPwith indoor coil EA*5X37M21A and furnace *80VTL1102122ACarrier3 tons35,800 Btu/h · Ducted2.2648%7.816.013.016,900None995214161995
380(C,H,T)5H8T36*K*AAA*KENMORE · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *97VTN1002122ACarrier3 tons36,000 Btu/h · Ducted2.4051%8.515.012.019,200CEE 25CEE 26840216357661
381235SAE036**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FJ5AN*C48LCarrier3 tons36,800 Btu/h · Ducted2.2048%8.016.013.017,400CEE 25108217033613
382235SAN030**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons27,000 Btu/h · Ducted2.6657%7.515.212.016,500None1,154216598661
383235SAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 252,154216598662
384235SAP036**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FMA5X36**ALCarrier3 tons35,000 Btu/h · Ducted2.2048%7.815.512.517,100None102217033511
385246SAN030**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons27,000 Btu/h · Ducted2.6657%7.515.212.016,500None1,072216598669
386246SAN031**AA*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED 16 SEER2 HPwith indoor coil CAA**3721AM and furnace 83*CB36040C17Carrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 25691217680504
387246SAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 252,081216598670
388248TAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CP37D3J+TDR and furnace 82*TB66135V24Carrier3 tons34,600 Btu/h · Ducted3.0558%7.815.511.722,400CEE 25CEE 261,667217677520
389249VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler F55AA*B36LCarrier3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC879217928529
39027SCA531A**30*CARRIER · COMFORT 15 SEER2 HPwith ducted air handler FJ5AN*B30LCarrier2.5 tons27,600 Btu/h · Ducted2.0046%7.815.512.513,400None1217679929
39127SCA536A**30*CARRIERwith indoor coil C(A,C,D,E)36B3J+TDR and furnace 58SU*B080M21**20Carrier2.5 tons31,200 Btu/h · Ducted2.6668%7.514.811.722,600CEE 252,017217178214
39227SCA536A**50*CARRIER · COMFORT 15 SEER2 HPwith ducted air handler FMA5X36**ALCarrier3 tons35,000 Btu/h · Ducted2.2048%7.815.512.517,100None104217033510
39327SCA536A**60*CARRIER · COMFORT 15 SEER2 HPwith ducted air handler FJ5AN*C48LCarrier3 tons36,800 Btu/h · Ducted2.2048%8.016.013.017,400CEE 25111217033611
39427SPA631A**30*CARRIER · PERFORMANCE 16 SEER2 HPwith indoor coil CAA**3721AM and furnace 58CU*B040C17**12Carrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 25702217689952
39527SPA636A**30*CARRIERwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 251,692217006650
39627TPA836A**30*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60LCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 261,405215628934
39727VNA036A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC852215670616
39827VNA336A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,000 Btu/h · Ducted2.1075%9.522.012.525,200CEE 25CEE 26XcelES CC629215933964
39927VPA936A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler F55AA*B36LCarrier3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC946217908868
400290VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC1,240215670617

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,722 models; narrow the filters for the rest.