# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
426(C,H,T)5H8T36*K*AAA*KENMORE · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *97VTN1002122ACarrier3 tons36,000 Btu/h · Ducted2.4051%8.515.012.019,200CEE 25CEE 26840216357661
427235SAE036**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FJ5AN*C48LCarrier3 tons36,800 Btu/h · Ducted2.2048%8.016.013.017,400CEE 25148217033613
428235SAN030**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons27,000 Btu/h · Ducted2.6657%7.515.212.016,500None1,273216598661
429235SAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 252,426216598662
430235SAP036**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FMA5X36**ALCarrier3 tons35,000 Btu/h · Ducted2.2048%7.815.512.517,100None139217033511
431246SAN030**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons27,000 Btu/h · Ducted2.6657%7.515.212.016,500None1,191216598669
432246SAN031**AA*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED 16 SEER2 HPwith indoor coil CAA**3721AM and furnace 83*CB36040C17Carrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 25840217680504
433246SAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 252,353216598670
434248TAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CP37D3J+TDR and furnace 82*TB66135V24Carrier3 tons34,600 Btu/h · Ducted3.0558%7.815.511.722,400CEE 25CEE 261,761217677520
435249VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler F55AA*B36LCarrier3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC879217928529
43627SCA531A**30*CARRIER · COMFORT 15 SEER2 HPwith ducted air handler FJ5AN*B30LCarrier2.5 tons27,600 Btu/h · Ducted2.0046%7.815.512.513,400None1217679929
43727SCA536A**30*CARRIERwith indoor coil C(A,C,D,E)36B3J+TDR and furnace 58SU*B080M21**20Carrier2.5 tons31,200 Btu/h · Ducted2.6668%7.514.811.722,600CEE 252,296217178214
43827SCA536A**50*CARRIER · COMFORT 15 SEER2 HPwith ducted air handler FMA5X36**ALCarrier3 tons35,000 Btu/h · Ducted2.2048%7.815.512.517,100None141217033510
43927SCA536A**60*CARRIER · COMFORT 15 SEER2 HPwith ducted air handler FJ5AN*C48LCarrier3 tons36,800 Btu/h · Ducted2.2048%8.016.013.017,400CEE 25151217033611
44027SPA631A**30*CARRIER · PERFORMANCE 16 SEER2 HPwith indoor coil CAA**3721AM and furnace 58CU*B040C17**12Carrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 25851217689952
44127SPA636A**30*CARRIERwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 251,976217006650
44227TPA836A**30*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60LCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 261,505215628934
44327VNA036A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC863215670616
44427VNA336A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,000 Btu/h · Ducted2.1075%9.522.012.525,200CEE 25CEE 26XcelES CC640215933964
44527VPA936A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler F55AA*B36LCarrier3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC946217908868
446290VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC1,256215670617
447293VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,000 Btu/h · Ducted2.1075%9.522.012.525,200CEE 25CEE 26XcelES CC960215933965
44837MAHAQ33AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ36XB3Carrier3 tons33,000 Btu/h · Ducted and non-ducted2.0097%10.016.711.734,000CEE 25CEE 26XcelES CC10215318766
44937MARAQ30AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ30XB3Carrier2.5 tons30,000 Btu/h · Ducted and non-ducted2.1068%8.817.011.020,400CEE 25CEE 2610215413022
45037MARAQ36AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ36XB3Carrier3 tons36,000 Btu/h · Ducted and non-ducted2.0062%7.716.08.623,000None10215413023