- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
2,722 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 451549LJ04***********BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons35,000 Btu/h · Ducted | 1.72 | 38% | 6.7 | 16.0 | 12.0 | 12,500 | None | 1 | 216794018 |
| 452549LP04***********BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons35,000 Btu/h · Ducted | 1.72 | 38% | 6.7 | 16.0 | 12.0 | 12,500 | None | 1 | 216794020 |
| 453549LT04***********BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons35,000 Btu/h · Ducted | 1.72 | 38% | 6.7 | 16.0 | 12.0 | 12,500 | None | 1 | 216794022 |
| 454549QE04**********BRYANT HEATING AND COOLING SYSTEMS · Preferred | Carrier | 3 tons35,000 Btu/h · Ducted | 1.70 | 38% | 6.7 | 15.3 | 12.0 | 12,000 | None | 1 | 217994664 |
| 455549QJ04**********BRYANT HEATING AND COOLING SYSTEMS · Preferred | Carrier | 3 tons35,000 Btu/h · Ducted | 1.70 | 38% | 6.7 | 15.3 | 12.0 | 12,000 | None | 1 | 217994665 |
| 456549QP04**********BRYANT HEATING AND COOLING SYSTEMS · Preferred | Carrier | 3 tons35,000 Btu/h · Ducted | 1.70 | 38% | 6.7 | 15.3 | 12.0 | 12,000 | None | 1 | 217994666 |
| 457549QT04**********BRYANT HEATING AND COOLING SYSTEMS · Preferred | Carrier | 3 tons35,000 Btu/h · Ducted | 1.70 | 38% | 6.7 | 15.3 | 12.0 | 12,000 | None | 1 | 217994667 |
| 458605CEXB36000AA*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons33,800 Btu/h · Ducted | 1.80 | 40% | 6.7 | 13.4 | 11.1 | 14,100 | None | 1 | 215576113 |
| 459605CNXB30000AA*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 2.5 tons28,600 Btu/h · Ducted | 1.60 | 41% | 6.7 | 13.4 | 11.1 | 11,500 | None | 1 | 215576064 |
| 460605CNXB36000AA*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons33,800 Btu/h · Ducted | 1.80 | 40% | 6.7 | 13.4 | 11.1 | 14,100 | None | 1 | 215576081 |
| 461605CPXB36000AA*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons33,800 Btu/h · Ducted | 1.80 | 40% | 6.7 | 13.4 | 11.1 | 14,100 | None | 1 | 215576098 |
| 462605EEXB36000AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred HP | Carrier | 3 tons35,200 Btu/h · Ducted | 1.70 | 41% | 7.2 | 15.2 | 11.5 | 14,100 | None | 1 | 217154421 |
| 463605ENXB36000AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred HP | Carrier | 3 tons35,200 Btu/h · Ducted | 1.70 | 41% | 7.2 | 15.2 | 11.5 | 14,100 | None | 1 | 217154397 |
| 464605EPXB36000AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred HP | Carrier | 3 tons35,200 Btu/h · Ducted | 1.70 | 41% | 7.2 | 15.2 | 11.5 | 14,100 | None | 1 | 217154409 |
| 465675CNWB30****A*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 2.5 tons28,600 Btu/h · Ducted | 1.60 | 41% | 6.7 | 13.4 | 11.1 | 11,500 | None | 1 | 215575987 |
| 466675CNWB36****A*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons33,800 Btu/h · Ducted | 1.80 | 40% | 6.7 | 13.4 | 11.1 | 14,100 | None | 1 | 215575999 |
| 467675ENWB36****A*BRYANT HEATING AND COOLING SYSTEMS · Preferred HP | Carrier | 3 tons35,200 Btu/h · Ducted | 1.70 | 41% | 7.2 | 15.2 | 11.5 | 14,100 | None | 1 | 217154382 |
| 468B5H0V36*K*AAA*HEIL · QUIETCOMFORT DELUXE 20 VS HPwith ducted air handler FCMA5B60L0D*+WALLCON | Carrier | 3 tons35,400 Btu/h · Ducted | 2.04 | 72% | 9.5 | 19.5 | 11.5 | 24,400 | CEE 25CEE 26XcelES CC | 5,402 | 218162463 |
| 469B5H3V36*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith ducted air handler FCMA5B60L0D*+WALLCON | Carrier | 3 tons35,000 Btu/h · Ducted | 2.10 | 75% | 9.5 | 22.0 | 12.5 | 25,200 | CEE 25CEE 26XcelES CC | 4,125 | 218405880 |
| 470B5H6S30*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FMA5X30**AL | Carrier | 2.5 tons29,000 Btu/h · Ducted | 2.26 | 48% | 8.1 | 15.2 | 12.5 | 13,900 | None | 2,358 | 218188546 |
| 471B5H6S31*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith indoor coil EA*5X37M21A*+WALLCON and furnace *80CSU0401712B | Carrier | 2.5 tons29,200 Btu/h · Ducted | 2.06 | 46% | 8.0 | 15.5 | 12.0 | 13,900 | CEE 25 | 4,735 | 218188957 |
| 472B5H6S36*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FHMA5*48L*C | Carrier | 3 tons36,400 Btu/h · Ducted | 2.24 | 50% | 7.8 | 15.5 | 13.0 | 17,500 | None | 5,221 | 218192493 |
| 473C5H0V36*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCON | Carrier | 3 tons35,400 Btu/h · Ducted | 2.04 | 72% | 9.5 | 19.5 | 11.5 | 24,400 | CEE 25CEE 26XcelES CC | 2,526 | 215670621 |
| 474C5H3V36*K*AAA*COMFORTMAKER · SoftSound 23 VS Heat Pumpwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122B | Carrier | 3 tons35,600 Btu/h · Ducted | 2.14 | 75% | 9.0 | 22.0 | 12.5 | 28,400 | CEE 25CEE 26XcelES CC | 1,827 | 215936669 |
| 475C5H6S30*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith indoor coil ESH5X30M12A and furnace *80CTL1102120A | Carrier | 2.5 tons28,400 Btu/h · Ducted | 2.26 | 46% | 7.8 | 15.5 | 12.5 | 13,000 | None | 1,511 | 214167855 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,722 models; narrow the filters for the rest.