Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
2,834 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 526D5CURAH36AAK+KSAIC0701230TEMPSTAR · Crossover heat pumpwith ducted air handler FHMA5*48L*C | Carrier | 3.5 tons39,500 Btu/h · Ducted | 2.36 | 68% | 8.5 | 15.2 | 9.8 | 24,400 | None | 3,288 | 218593804 |
| 527D5CURAH48AAKHEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0D | Carrier | 4 tons47,500 Btu/h · Ducted | 1.86 | 81% | 8.0 | 15.5 | 9.5 | 37,600 | CEE 25CEE 26XcelES CC | 650 | 216772706 |
| 528D5CURAH48AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X61M24A and furnace *80VSL0902120B | Carrier | 4 tons48,000 Btu/h · Ducted | 2.00 | 78% | 8.0 | 15.0 | 8.5 | 38,000 | ES CC | 738 | 218477572 |
| 529D5CURAH60AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDR | Carrier | 4 tons48,000 Btu/h · Ducted | 2.41 | 68% | 7.5 | 14.3 | 8.2 | 32,800 | ES CC | 99 | 217906677 |
| 530D5CURAH60AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0D | Carrier | 4.5 tons52,000 Btu/h · Ducted | 1.86 | 64% | 7.5 | 14.5 | 9.0 | 38,500 | None | 26 | 218475433 |
| 531GH5SAN542**AA*CARRIERwith ducted air handler L(E,G)M48FJ | Carrier | 3.5 tons42,000 Btu/h · Ducted | 2.65 | 60% | 7.8 | 14.8 | 12.0 | 23,400 | None | 1,764 | 217195004 |
| 532GH5SAN548**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+CM59A4J+TDR | Carrier | 3.5 tons44,000 Btu/h · Ducted | 2.70 | 61% | 7.5 | 14.8 | 11.7 | 28,400 | None | 1,492 | 215828001 |
| 533GH5SAN560**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+DM60B4J+TDR | Carrier | 4.5 tons53,500 Btu/h · Ducted | 2.60 | 64% | 7.5 | 14.3 | 11.7 | 34,800 | None | 35 | 215828002 |
| 534GH8TAN548**AA*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L | Carrier | 4 tons48,500 Btu/h · Ducted | 2.32 | 51% | 8.1 | 18.0 | 13.5 | 24,600 | CEE 25CEE 26 | 2,437 | 215560705 |
| 535GH8TAN560**AA*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace 58TN*B135C24**22 | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.34 | 52% | 8.5 | 15.5 | 11.5 | 31,400 | CEE 25CEE 26 | 1,426 | 215626617 |
| 536H5H0V48*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A | Carrier | 3.5 tons43,000 Btu/h · Ducted | 2.70 | 103% | 9.0 | 18.0 | 9.0 | 50,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,250 | 218372714 |
| 537H5H0V60*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120B | Carrier | 4.5 tons51,500 Btu/h · Ducted | 2.39 | 102% | 8.1 | 18.5 | 8.5 | 59,000 | CEE 25CEE 26CEE AdvDOEES CC | 593 | 218372772 |
| 538H5H3V48*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CSU1002120A | Carrier | 3.5 tons43,500 Btu/h · Ducted | 2.00 | 76% | 9.5 | 20.5 | 10.5 | 36,600 | CEE 25CEE 26XcelES CC | 1,025 | 215933976 |
| 539H5H3V60*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716B | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.10 | 75% | 8.5 | 18.0 | 11.0 | 45,500 | CEE 25CEE 26XcelES CC | 549 | 215931656 |
| 540H5H6S42*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *96MSN1002122A | Carrier | 3.5 tons39,500 Btu/h · Ducted | 2.66 | 62% | 7.5 | 14.5 | 11.2 | 24,800 | None | 725 | 218372569 |
| 541H5H6S48*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *80MS(N,L)1102420A | Carrier | 3.5 tons44,000 Btu/h · Ducted | 2.61 | 60% | 7.5 | 14.3 | 11.2 | 29,200 | None | 731 | 218372584 |
| 542H5H8T48*K*AAA*HEIL · Mainline 18 SEER2 HPwith ducted air handler FTMA5B60L0D | Carrier | 4 tons48,500 Btu/h · Ducted | 2.34 | 51% | 8.1 | 18.0 | 13.5 | 24,600 | CEE 25CEE 26 | 1,899 | 216151902 |
| 543H5H8T60*K*AAA*HEIL · Mainline 18 SEER2 HPwith indoor coil EVM5X61M24A*+WALLCON and furnace *80CSU0802120B | Carrier | 4.5 tons55,500 Btu/h · Ducted | 2.36 | 52% | 8.5 | 15.5 | 12.0 | 30,800 | CEE 25CEE 26 | 1,324 | 216346846 |
| 544HH860E2S11KENMOREwith ducted air handler CTF60D5CGS1+JME18D2SN1 | Carrier | 4 tons46,000 Btu/h · Ducted | 2.00 | 74% | 9.5 | 19.0 | 12.0 | 33,800 | CEE 25CEE 26Xcel | 62 | 216591042 |
| 545HH860E2S11*KENMORE · LX SERIESwith ducted air handler JHE48D5CG2SS2 | Carrier | 4 tons45,000 Btu/h · Ducted | 2.24 | 75% | 9.0 | 18.5 | 12.0 | 33,400 | CEE 25CEE 26Xcel | 331 | 218821670 |
| 546HH860E2S12KENMORE · LX SERIESwith ducted air handler CTF60D5CGS2+JME18D2SN2 | Carrier | 4 tons46,000 Btu/h · Ducted | 2.32 | 77% | 8.5 | 17.5 | 12.0 | 36,000 | CEE 25CEE 26Xcel | 405 | 218642261 |
| 547MCY-MUB0488HS2P-ULTOSHIBA CARRIER · MCY-MUB0488HS2P-UL | Carrier | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.50 | 70% | 11.3 | 24.4 | 13.4 | 38,000 | CEE 25CEE 26XcelES CC | 7 | 216760288 |
| 548MCY-MUB0608HS2P-ULTOSHIBA CARRIER · Toshiba Miniwith ducted air handler MMD-UB0601VHN-UL | Carrier | 4.5 tons54,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.25 | 59% | 9.3 | 15.3 | 9.6 | 38,000 | CEE 25CEE 26Xcel | 5 | 218066442 |
| 549N5H5S48*H*AAA*HEILwith ducted air handler 98-8810+TXV+RDS+TDR+E30B5D | Carrier | 4 tons45,000 Btu/h · Ducted | 2.26 | 55% | 7.8 | 15.2 | 12.0 | 23,800 | None | 158 | 216508704 |
| 550N5H5S48*K*AAA*TEMPSTARwith indoor coil D(A,C,E)60D3J+TDR and furnace *80MS(N,L)1102420A | Carrier | 4 tons45,500 Btu/h · Ducted | 2.75 | 60% | 7.5 | 14.8 | 11.0 | 29,400 | None | 3,588 | 217597761 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,834 models; narrow the filters for the rest.