Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

13,619 models

Sorted by manufacturer and model.
Page 22 of 545
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
526AC-36-HP-E-32AireForce · Mini-spilt Ducted serieswith ducted air handler AC-36-AH-E-32AireForce3 tons35,000 Btu/h · Ducted2.0066%8.617.09.525,000None1218729453
527AC-36Z-E-M4AireForce · Multi-spilt seriesAireForce3 tons36,000 Btu/h · Non-ducted2.0071%10.023.012.325,600CEE 25CEE 26Xcel1218729437
528AC-42Z-E-M5AireForce · Multi-spilt seriesAireForce3 tons37,000 Btu/h · Non-ducted2.0088%10.022.012.032,400CEE 25CEE 26Xcel1218729438
529AC-48-HP-E-32AireForce · Mini-spilt Ducted serieswith ducted air handler AC-48-AH-E-32AireForce4 tons48,000 Btu/h · Ducted2.1084%9.016.09.540,500None1218729454
530AC-60-HP-E-32AireForce · Mini-spilt Ducted serieswith ducted air handler AC-60-AH-E-32AireForce4.5 tons55,000 Btu/h · Ducted2.0075%9.016.09.541,500None1218729455
531AC2018K230R3AAireforceAireForce1.5 tons18,000 Btu/h · Non-ducted2.0078%10.025.011.714,000CEE 25CEE 26Xcel1218858126
532AC2027K230R3AAireforceAireForce2.5 tons28,000 Btu/h · Non-ducted2.0075%10.022.011.221,000CEE 25CEE 26Xcel1218858127
533AC2036K230R3AAireforceAireForce3 tons38,000 Btu/h · Non-ducted2.0074%10.023.011.231,000CEE 25CEE 26Xcel1218858128
534AC2042K230R3AAireforceAireForce3.5 tons42,000 Btu/h · Non-ducted2.0074%10.024.011.231,000CEE 25CEE 26Xcel1218858129
535DXH09ESA3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH09ESA3ILAireForce1 ton9,100 Btu/h · Non-ducted1.8676%8.820.511.97,600CEE 25CEE 26Xcel1216011722
536DXH09ESK3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH09ESK3ILAireForce1 ton9,100 Btu/h · Non-ducted1.9476%8.820.512.57,600CEE 25CEE 26Xcel1216011721
537DXH09PSK3IHAireForce · Multizone Indoors Eight-way Compact Cassetteswith ductless indoor unit DKH09FMK3IHAireForce1 ton9,100 Btu/h · Non-ducted1.9472%9.224.015.07,600CEE 25CEE 26XcelES CC2216011797
538DXH12ESA3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH12ESA3ILAireForce1 ton12,000 Btu/h · Non-ducted1.8171%8.519.09.38,500Xcel1216011726
539DXH12ESK3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH12ESK3ILAireForce1 ton12,000 Btu/h · Non-ducted1.8076%8.519.09.89,100Xcel1216011725
540DXH12PSK3IHAireForce · (24-26 SEER2) Minisplitswith ductless indoor unit DHH12PUK3IHAireForce1 ton12,000 Btu/h · Non-ducted1.9592%9.524.513.011,000CEE 25CEE 26XcelES CC2216011729
541DXH18ESK3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH18ESK3ILAireForce1.5 tons18,000 Btu/h · Non-ducted1.8571%8.520.012.012,100CEE 25CEE 26Xcel1216011728
542DXH18FMK3IHAireForce · Multizone OutdoorsAireForce1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0077%10.021.012.013,800CEE 25CEE 26XcelES CC3215746280
543DXH18PSK3IHAireForce · (24-26 SEER2) Minisplitswith ductless indoor unit DHH18PUK3IHAireForce1.5 tons18,000 Btu/h · Non-ducted1.9081%9.024.513.714,600CEE 25CEE 26XcelES CC2216011732
544DXH24ESK3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH24ESK3ILAireForce2 tons24,000 Btu/h · Non-ducted1.7570%8.519.011.915,700CEE 25CEE 26Xcel1216011724
545DXH24FMK3IHAireForce · Multizone OutdoorsAireForce2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.013.321,600CEE 25CEE 26XcelES CC3215746281
546DXH24PSK3IHAireForce · (24-26 SEER2) Minisplitswith ductless indoor unit DHH24PUK3IHAireForce2 tons22,000 Btu/h · Non-ducted1.8079%10.026.013.719,000CEE 25CEE 26XcelES CC2216011731
547DXH30ESK3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH30ESK3ILAireForce2.5 tons30,000 Btu/h · Non-ducted1.8077%9.022.011.023,000CEE 25CEE 26Xcel1216011730
548DXH30FMK3IHAireForce · Multizone OutdoorsAireForce2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0790%10.021.013.627,000CEE 25CEE 26XcelES CC3215746282
549DXH36ESK3ILAireForce · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH36ESK3ILAireForce3 tons33,600 Btu/h · Non-ducted1.8072%8.521.012.024,600CEE 25CEE 26XcelES CC1216011723
550DXH36FMK3IHAireForce · Multizone OutdoorsAireForce3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.10100%10.021.012.036,000CEE 25CEE 26CEE AdvXcelDOEES CC3215746283

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 13,619 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy