Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

2,724 models

Sorted by manufacturer and model.
Page 24 of 109
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
576W5H5S30*K*AAA*GRANDAIREwith ducted air handler L(E,G)M36FJCarrier2.5 tons28,200 Btu/h · Ducted2.6057%7.514.512.016,400None569218158199
577W5H5S31*K*AAA*GRANDAIRE · 15 SEER2 HPwith indoor coil W5A*43M21XA and furnace WFEU060B048BCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.014,000CEE 25452217692221
578W5H5S36*K*AAA*GRANDAIREwith ducted air handler L(E,G)M48BJCarrier3 tons33,600 Btu/h · Ducted2.4655%7.814.812.019,600CEE 25798218158210
579W5H8T36*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith ducted air handler WCGL605*DCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.013.018,600CEE 25CEE 26418215628959
580W5H9V30AKAAAGrandaire · W5H Serieswith ducted air handler WCVL305CBCarrier2.5 tons30,000 Btu/h · Ducted1.9696%10.016.811.732,600CEE 25CEE 26XcelES CC1218160682
581W5H9V36AKAAAGrandaire · W5H Serieswith ducted air handler WCVL365CCCarrier3 tons36,000 Btu/h · Ducted1.90105%10.317.411.739,000CEE 25CEE 26XcelES CC17218160677
582WJH530000K000B*GRANDAIRECarrier2.5 tons28,600 Btu/h · Ducted1.7539%6.713.411.111,100None2216411352
583WJH536000K000B*GRANDAIRECarrier3 tons35,200 Btu/h · Ducted1.6039%6.713.411.112,700None2216411353
584WN036C***1*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122000
585WN036C***2*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122002
586WN036C***4*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122003
587WN036C***5*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122004
588WN036E***1*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122001
589WN036E***2*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122005
590WN036E***4*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122006
591WN036E***5*******1KENMORECarrier3 tons38,000 Btu/h · Ducted——6.713.411.4—None1217122007
592WPH530A000RKB*GRANDAIRECarrier2.5 tons28,600 Btu/h · Ducted1.6041%6.713.411.111,500None2215576079
593WPH536A000RKB*GRANDAIRECarrier3 tons33,800 Btu/h · Ducted1.8040%6.713.411.114,100None2215576096
594WQE04A1**********1KENMORE · CORECarrier3 tons35,600 Btu/h · Ducted——6.714.012.2—None1217121980
595WQE04A2**********1KENMORE · CORECarrier3 tons35,600 Btu/h · Ducted——6.714.012.2—None1217121981
596WQE04A4**********1KENMORE · CORECarrier3 tons35,600 Btu/h · Ducted——6.714.012.2—None1217121982
597WQE04A5**********1KENMORE · CORECarrier3 tons35,600 Btu/h · Ducted——6.714.012.2—None1217121983
598WYE04A1**********1KENMORE · CORECarrier3 tons36,000 Btu/h · Ducted——7.114.512.2—None1217121976
599WYE04A2**********1KENMORE · CORECarrier3 tons36,000 Btu/h · Ducted——7.114.512.2—None1217121994
600WYE04A4**********1KENMORE · CORECarrier3 tons36,000 Btu/h · Ducted——7.114.512.2—None1217121995

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,724 models; narrow the filters for the rest.