Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
7,790 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 7376WDHP-24HHWells · WDHP Serieswith ducted air handler WDAH-24MOC | Wells | 2 tons23,000 Btu/h · Ducted | 1.87 | 90% | 10.0 | 18.3 | 11.7 | 21,600 | CEE 25CEE 26XcelES CC | 5 | 215864027 |
| 7377WDHP-30HHWells · WDHP Serieswith ducted air handler WDAH-30MOC | Wells | 2.5 tons30,000 Btu/h · Ducted | 1.96 | 96% | 10.0 | 16.8 | 11.7 | 32,600 | CEE 25CEE 26XcelES CC | 6 | 215864028 |
| 7378WDHP-36HHWells · WDHP Serieswith ducted air handler WDAH-36MOC | Wells | 3 tons36,000 Btu/h · Ducted | 1.90 | 105% | 10.3 | 17.4 | 11.7 | 39,000 | CEE 25CEE 26XcelES CC | 5 | 215864029 |
| 7379WDHP-36RHWells · WDHP Serieswith ducted air handler WDAH-36MOC | Wells | 3 tons36,000 Btu/h · Ducted | 2.00 | 75% | 8.7 | 16.1 | 10.0 | 27,000 | CEE 25CEE 26XcelES CC | 1 | 215864025 |
| 7380WDHP-4860T-GWELLS · Ducted Central Airwith ducted air handler WDAH-48MOC-G | Wells | 4 tons47,500 Btu/h · Ducted | 2.10 | 71% | 9.0 | 17.5 | 11.3 | 34,200 | CEE 25CEE 26XcelES CC | 2 | 217048503 |
| 7381WDHP-48HHWells · WDHP Serieswith ducted air handler WDAH-48MOC | Wells | 4 tons48,000 Btu/h · Ducted | 1.90 | 92% | 9.5 | 16.5 | 10.5 | 46,000 | CEE 25CEE 26XcelES CC | 2 | 215864030 |
| 7382WDHP-60HHWells · WDHP Serieswith ducted air handler WDCA-48/60D | Wells | 4 tons47,000 Btu/h · Ducted | 1.83 | 74% | 8.1 | 15.2 | 10.0 | 43,000 | CEE 25CEE 26XcelES CC | 4 | 217022373 |
| 7383WOM-18HH3/230Wells · WOM Series | Wells | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 90% | 10.0 | 21.0 | 13.0 | 18,000 | CEE 25CEE 26XcelES CC | 3 | 215864105 |
| 7384WOM-18RH3/230Wells · WOM Series | Wells | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.30 | 77% | 10.0 | 20.0 | 12.0 | 14,600 | CEE 25CEE 26XcelES CC | 3 | 215864091 |
| 7385WOM-27HH4/230Wells · WOM Series | Wells | 2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 9.5 | 19.0 | 12.0 | 27,000 | CEE 25CEE 26XcelES CC | 3 | 215864109 |
| 7386WOM-27RH4/230Wells · WOM Series | Wells | 2 tons26,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 23.0 | 12.2 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 215864093 |
| 7387WOM-36HH5/230Wells · WOM Series | Wells | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 106% | 10.4 | 19.4 | 12.0 | 38,000 | CEE 25CEE 26XcelES CC | 3 | 215864112 |
| 7388WOM-36RH5/230Wells · WOM Series | Wells | 3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 10.0 | 23.1 | 12.0 | 26,000 | CEE 25CEE 26XcelES CC | 3 | 215864096 |
| 7389WOM-48HH6/230Wells · WOM Series | Wells | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 98% | 10.2 | 21.2 | 12.0 | 48,000 | CEE 25CEE 26XcelES CC | 3 | 215864114 |
| 7390WOM-48RH6/230Wells · WOM Series | Wells | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 75% | 10.0 | 21.3 | 11.7 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 215864099 |
| 7391WOM-60HH6/230Wells · WOM Series | Wells | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26XcelES CC | 3 | 215864118 |
| 7392WOM-60RH6/230Wells | Wells | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 67% | 9.2 | 18.0 | 10.0 | 40,000 | CEE 25CEE 26 | 3 | 215864103 |
| 7393WOS-06PRE/230Wells · WOS Serieswith ducted air handler WIDL-06MOC/230 | Wells | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.4 | 14.4 | 7,800 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215864077 |
| 7394WOS-09ECO/115Wellswith ductless indoor unit WIHW-09ECO/115 | Wells | 1 ton9,000 Btu/h · Non-ducted | 1.83 | 61% | 9.0 | 18.0 | 10.1 | 6,000 | CEE 25 | 1 | 215864032 |
| 7395WOS-09ECO/230Wells · WOS Serieswith ductless indoor unit WIHW-09ECO/230 | Wells | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 70% | 9.7 | 19.0 | 10.9 | 7,000 | CEE 25CEE 26XcelES CC | 1 | 215864034 |
| 7396WOS-09PRE/230Wells · WOS Serieswith ducted air handler WIDL-09MOC/230 | Wells | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.89 | 112% | 12.5 | 21.4 | 13.4 | 11,200 | CEE 25CEE 26XcelES CC | 6 | 215864078 |
| 7397WOS-09QUA/115Wells · WOS Serieswith ductless indoor unit WIHW-09QUA/115 | Wells | 1 ton9,000 Btu/h · Non-ducted | 2.21 | 73% | 10.7 | 24.5 | 15.0 | 7,300 | CEE 25CEE 26XcelES CC | 1 | 215864038 |
| 7398WOS-09QUA/230Wells · WOS Serieswith ductless indoor unit WIHW-09MOC/230 | Wells | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.33 | 82% | 13.0 | 24.6 | 14.7 | 8,200 | CEE 25CEE 26XcelES CC | 6 | 215864040 |
| 7399WOS-12PRE/230Wells · WOS Serieswith ductless indoor unit WI4C-12MOC/230 | Wells | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 96% | 11.6 | 22.2 | 12.5 | 11,500 | CEE 25CEE 26XcelES CC | 6 | 215864070 |
| 7400WOS-12QUA/115Wells · WOS Serieswith ductless indoor unit WIHW-12QUA/115 | Wells | 1 ton12,000 Btu/h · Non-ducted | 2.21 | 61% | 10.4 | 23.2 | 12.5 | 7,300 | CEE 25CEE 26 | 1 | 215864039 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,790 models; narrow the filters for the rest.