- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
5,427 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 801D5CUHAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,400 Btu/h · Ducted | 2.04 | 83% | 9.0 | 16.0 | 11.0 | 16,800 | CEE 25CEE 26XcelES CC | 1,789 | 218483199 |
| 802D5CUHAH18AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,400 Btu/h · Ducted | 2.04 | 83% | 9.0 | 16.0 | 11.0 | 16,800 | CEE 25CEE 26XcelES CC | 1,809 | 217399865 |
| 803D5CURAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 1.5 tons17,700 Btu/h · Ducted | 2.83 | 75% | 7.8 | 16.0 | 10.0 | 13,300 | CEE 25CEE 26Xcel | 2,302 | 217906671 |
| 804D5CURAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,200 Btu/h · Ducted | 2.10 | 61% | 9.0 | 17.0 | 10.5 | 11,800 | CEE 25CEE 26 | 3,118 | 218609651 |
| 805D5CVRAH09AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAJ | Carrier | 1 ton9,000 Btu/h · Non-ducted | 1.83 | 61% | 9.0 | 18.0 | 10.1 | 6,000 | CEE 25 | 18 | 215324153 |
| 806D5CVRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAK | Carrier | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 70% | 9.7 | 19.0 | 10.9 | 7,000 | CEE 25CEE 26XcelES CC | 18 | 215324155 |
| 807D5CVRAH12AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH12XAJ | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.21 | 58% | 9.2 | 19.0 | 8.8 | 7,000 | None | 18 | 215324154 |
| 808D5CVRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH12XAK | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.21 | 58% | 8.8 | 18.0 | 8.8 | 7,000 | None | 18 | 215324156 |
| 809D5CVRAH18AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH18XAK | Carrier | 1.5 tons17,000 Btu/h · Non-ducted | 2.10 | 59% | 8.7 | 18.3 | 9.9 | 10,600 | None | 18 | 215324157 |
| 810GH5SAN518**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)29J | Carrier | 1.5 tons16,900 Btu/h · Ducted | 2.52 | 55% | 7.5 | 15.2 | 12.0 | 9,800 | None | 2,107 | 217229864 |
| 811GH5SAN519**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**1917AM and furnace 82*TB48070V17 | Carrier | 1.5 tons19,200 Btu/h · Ducted | 2.00 | 43% | 8.0 | 15.5 | 13.0 | 8,400 | None | 1,691 | 217683721 |
| 812H5H6S18*K*AAA*HEILwith indoor coil D(A,C,E)31A3J+TDR and furnace *80MS(N,L)0701716A | Carrier | 1.5 tons16,300 Btu/h · Ducted | 2.51 | 63% | 7.8 | 14.8 | 11.7 | 10,400 | None | 1,653 | 218371852 |
| 813H5H6S19*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FM(C,U)5Z18**AL | Carrier | 1.5 tons18,000 Btu/h · Ducted | 2.00 | 43% | 7.8 | 15.5 | 13.0 | 8,100 | None | 1,878 | 217687301 |
| 814N5H5S18*K*AAA*HEILwith indoor coil D(A,C,E)30B3J+TDR and furnace *80MS(N,L)0701716A | Carrier | 1.5 tons16,400 Btu/h · Ducted | 2.53 | 63% | 7.8 | 14.8 | 11.7 | 10,400 | CEE 25 | 6,905 | 217597785 |
| 815PH5SAN518**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)27J | Carrier | 1.5 tons16,600 Btu/h · Ducted | 2.50 | 55% | 7.5 | 15.2 | 11.7 | 9,800 | None | 2,534 | 217006631 |
| 816PH5SAN518**AB*WEATHERMAKERwith indoor coil D(A,C,E)31A3J+TDR and furnace PG80MS(A,L)A42045B | Carrier | 1.5 tons16,100 Btu/h · Ducted | 2.48 | 65% | 7.5 | 14.5 | 11.2 | 10,500 | None | 393 | 218863214 |
| 817PH5SAN519**AA*PAYNE HEATING AND COOLINGwith indoor coil D(A,C,E)31A3J+TDR and furnace PG92MSAA60080C | Carrier | 1.5 tons17,600 Btu/h · Ducted | 2.45 | 47% | 7.5 | 14.5 | 12.5 | 9,000 | None | 1,493 | 218863289 |
| 818PH5SAN519**AB*WEATHERMAKERwith indoor coil D(A,C,E)31A3J+TDR and furnace PG92MSAA60080C | Carrier | 1.5 tons17,600 Btu/h · Ducted | 2.45 | 47% | 7.5 | 14.5 | 12.5 | 9,000 | None | 568 | 218863378 |
| 819R5H5S18*K*AAA*HEILwith indoor coil D(A,C,E)30B3J+TDR and furnace *80MS(N,L)0701716A | Carrier | 1.5 tons16,400 Btu/h · Ducted | 2.53 | 63% | 7.8 | 14.8 | 11.7 | 10,400 | CEE 25 | 6,694 | 217597120 |
| 820R5H5S19*K*AAA*TEMPSTARwith ducted air handler PE(S,T)29J | Carrier | 1.5 tons16,900 Btu/h · Ducted | 2.52 | 55% | 7.5 | 15.2 | 12.0 | 9,800 | None | 7,424 | 217889950 |
| 821RAV-BP121AT2P-ULTOSHIBA CARRIER · RAV-BP121AT2P-ULwith ductless indoor unit RAV-HB121UTP-ULNot ranked: cold-weather ratings look inconsistent. | Carrier | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.51 | 84% | 12.0 | 26.0 | 16.0 | 10,100 | CEE 25CEE 26XcelES CC | 3 | 216415462 |
| 822RAV-BP181AT2P-ULTOSHIBA CARRIER · RAV-BP181AT2P-ULwith ducted air handler RAV-HB181BTP-UL | Carrier | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.21 | 78% | 10.0 | 17.1 | 11.7 | 14,000 | CEE 25CEE 26XcelES CC | 4 | 216415475 |
| 823T5H6S18*K*AAA*TEMPSTAR · MAINLINE 16 SEER2 HPwith ducted air handler FMA5X24**AL | Carrier | 1.5 tons17,400 Btu/h · Ducted | 2.10 | 46% | 8.0 | 15.5 | 12.5 | 8,200 | None | 512 | 214423970 |
| 824T5H6S19*K*AAA*TEMPSTAR · MAINLINE 16 SEER2 HPwith indoor coil EA*5X19M17A and furnace *80VTL0701716B | Carrier | 1.5 tons19,200 Btu/h · Ducted | 2.00 | 43% | 8.0 | 15.5 | 13.0 | 8,400 | None | 613 | 217721564 |
| 825W5H5S18*K*AAA*GRANDAIREwith ducted air handler AE*S+CM24C2J+TDR | Carrier | 1.5 tons15,900 Btu/h · Ducted | 2.45 | 53% | 7.5 | 14.3 | 11.7 | 9,200 | None | 845 | 215876921 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 5,427 models; narrow the filters for the rest.