- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
2,724 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 876DIRM4-27DA25-3ZDIRECT AIR · DIRM Series | DIRECT AIR | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.5 | 23.0 | 12.5 | 27,000 | CEE 25CEE 26XcelES CC | 3 | 215213790 |
| 877DIRM4-27DA25-3Z*DIRECT AIR · DIRM Series | DIRECT AIR | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 25.0 | 13.0 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 216683820 |
| 878DIRM4-27DA25-4ZDIRECT AIR · DIRM Series | DIRECT AIR | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 25.0 | 13.0 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 218331785 |
| 879DIRM4-28HXPRO28-3ZDIRECT AIR · DIRM Series | DIRECT AIR | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.5 | 23.0 | 12.5 | 27,000 | CEE 25CEE 26XcelES CC | 3 | 215213802 |
| 880DIRM4-28HXPRO28-4ZDIRECT AIR · DIRM Series | DIRECT AIR | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.5 | 23.0 | 12.5 | 27,000 | CEE 25CEE 26XcelES CC | 3 | 218331797 |
| 881DIRM4-30CS19-OUDIRECT AIRwith ducted air handler DIRM4-30MAGICPRO20-AH | DIRECT AIR | 2.5 tons30,000 Btu/h · Ducted | 2.00 | 62% | 8.5 | 17.0 | 10.7 | 19,100 | CEE 25CEE 26 | 11 | 216571357 |
| 882DIRM4-30DA25-1ZDIRECT AIR · DIR Serieswith ductless indoor unit DIRM4-30HP-WM | DIRECT AIR | 2.5 tons30,000 Btu/h · Non-ducted | 2.03 | 67% | 9.5 | 20.5 | 12.0 | 20,000 | CEE 25CEE 26 | 1 | 216571376 |
| 883DIRM4-30MAGICPRO20-OUDIRECT AIR · DIR Serieswith ducted air handler DIRM4-30MAGICPRO20-AH | DIRECT AIR | 2.5 tons30,000 Btu/h · Ducted | 1.96 | 96% | 10.0 | 16.8 | 11.7 | 32,600 | CEE 25CEE 26XcelES CC | 13 | 216571363 |
| 884DIRM4-36CS19-OUDIRECT AIR · DIR Serieswith ducted air handler DIRM4-36MAGICPRO20-AH | DIRECT AIR | 3 tons36,000 Btu/h · Ducted | 2.00 | 75% | 8.7 | 16.1 | 10.0 | 27,000 | CEE 25CEE 26XcelES CC | 10 | 216571358 |
| 885DIRM4-36DA25-1ZDIRECT AIRwith ductless indoor unit DIRM4-36HP-WM | DIRECT AIR | 3 tons36,000 Btu/h · Non-ducted | 1.90 | 61% | 8.5 | 19.0 | 8.6 | 22,000 | None | 1 | 216571377 |
| 886DIRM4-36DA25-4ZDIRECT AIR · DIRM Series | DIRECT AIR | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 24.0 | 12.0 | 26,000 | CEE 25CEE 26XcelES CC | 3 | 215213793 |
| 887DIRM4-36DA25-5ZDIRECT AIR · DIRM Series | DIRECT AIR | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 24.0 | 12.0 | 26,000 | CEE 25CEE 26XcelES CC | 3 | 218331788 |
| 888DIRM4-36HXPRO28-4ZDIRECT AIR · DIRM Series | DIRECT AIR | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.7 | 23.0 | 13.0 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 215213805 |
| 889DIRM4-36HXPRO28-5ZDIRECT AIR · DIRM Series | DIRECT AIR | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.7 | 23.0 | 13.0 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 218331800 |
| 890DIRM4-36LCDA25-1ZDIRECT AIR · DIRM4 Serieswith ductless indoor unit DIRM4-36HP-CA | DIRECT AIR | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.20 | 70% | 10.3 | 20.0 | 9.6 | 26,600 | CEE 25CEE 26XcelES CC | 3 | 216788532 |
| 891DIRM4-36LCHX-1ZDIRECT AIR · DIRM4 Serieswith ducted air handler DIRM4-36HP-DU | DIRECT AIR | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.10 | 90% | 11.1 | 17.7 | 12.0 | 37,600 | CEE 25CEE 26XcelES CC | 3 | 216788531 |
| 892DIRM4-36MAGICPRO20-OUDIRECT AIR · DIR Serieswith ducted air handler DIRM4-36MAGICPRO20-AH | DIRECT AIR | 3 tons36,000 Btu/h · Ducted | 1.90 | 105% | 10.3 | 17.4 | 11.7 | 39,000 | CEE 25CEE 26XcelES CC | 12 | 216571364 |
| 893ACIQ-36-HP32DIYCOOL · R32 Extreme Heat Unitarywith ducted air handler ACIQ-36-AH32 | DIYCOOL | 3 tons34,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 18.2 | 11.5 | 34,000 | CEE 25CEE 26XcelES CC | 1 | 215387243 |
| 894EZ-36-EHPBDIYCOOL · EZ Serieswith ducted air handler EZ-36-AHB | DIYCOOL | 3 tons36,000 Btu/h · Ducted | 2.00 | 75% | 8.7 | 16.2 | 10.0 | 27,000 | CEE 25CEE 26XcelES CC | 1 | 216980842 |
| 895EZ-36-HPBDIYCOOL · EZ Serieswith ducted air handler EZ-36-AHB | DIYCOOL | 3 tons36,000 Btu/h · Ducted | 1.90 | 105% | 10.3 | 17.4 | 11.7 | 39,000 | CEE 25CEE 26XcelES CC | 1 | 216980846 |
| 896EZ-36Z-M4BDIYCOOL · EZ Series | DIYCOOL | 3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.9 | 23.0 | 12.0 | 25,200 | CEE 25CEE 26XcelES CC | 3 | 216980923 |
| 897EZ-36ZPL-HP230BDIYCOOLwith ductless indoor unit EZ-36W-MB | DIYCOOL | 3 tons36,000 Btu/h · Non-ducted | 1.97 | 61% | 8.5 | 18.0 | 8.5 | 22,000 | None | 1 | 216980900 |
| 898DMAC-36AW1domankiwith ductless indoor unit DMAC-36AG1 | domanki | 3 tons34,600 Btu/h · Non-ducted | — | — | 8.2 | 18.1 | 9.6 | — | None | 1 | 218258611 |
| 899454-36-5Z-ODUCTLESSAIRE · 454 Series | DUCTLESSAIRE | 3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 10.0 | 23.1 | 12.0 | 26,000 | CEE 25CEE 26XcelES CC | 3 | 217232140 |
| 900D5OD30-36HFN10-M1-DDUOHOME | DUOHOME | 3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 10.0 | 23.1 | 12.0 | 26,000 | CEE 25CEE 26Xcel | 3 | 217956866 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,724 models; narrow the filters for the rest.