Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

6,515 models

Sorted by manufacturer and model.
Page 39 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
951CPM5B1V-H48A-OCapella · CPM SeriesCapella4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.023.012.047,000CEE 25CEE 26XcelES CC3216027656
952CPM5B1V-H55A-OCapella · CPM SeriesCapella4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1087%10.720.011.748,000CEE 25CEE 26XcelES CC3216027660
953CPPB-H09A-OCapella · SFCB Serieswith ducted air handler SFCB1-H09A-ICapella1 ton9,000 Btu/h · Ducted and non-ducted1.85120%13.820.514.011,900CEE 25CEE 26XcelES CC5216027628
954CPPB-H12A-OCapella · SICB Serieswith ductless indoor unit SICB1-H12A-ICapella1 ton12,000 Btu/h · Ducted and non-ducted1.9996%11.622.212.511,500CEE 25CEE 26XcelES CC5216027625
955CPPB-H18A-OCapella · SFCB Serieswith ducted air handler SFCB1-H18A-ICapella1.5 tons17,500 Btu/h · Ducted and non-ducted2.1092%11.118.412.018,000CEE 25CEE 26XcelES CC5216027630
956CPPB-H24A-OCapella · CPPB Serieswith ductless indoor unit CPPB-H24A-ICapella2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.013.024,200CEE 25CEE 26XcelES CC5216027623
957(C,H,T)5H0V24*K*AAA*KENMORE · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5X24L0B*+WALLCONCarrier2 tons23,400 Btu/h · Ducted2.0468%9.017.510.516,600CEE 25CEE 26XcelES CC409215662832
958(C,H,T)5H0V36*K*AAA*KENMORE · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC831215670624
959(C,H,T)5H0V48*K*AAA*KENMORE · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier4 tons46,500 Btu/h · Ducted2.2070%9.519.510.533,000CEE 25CEE 26XcelES CC396215675351
960(C,H,T)5H3V36*K*AAA*KENMORE · Deluxe 23 VS Heat Pumpwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122BCarrier3 tons35,600 Btu/h · Ducted2.1475%9.022.012.528,400CEE 25CEE 26XcelES CC614215936672
961(C,H,T)5H3V48*K*AAA*KENMORE · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CSU1002120ACarrier3.5 tons43,500 Btu/h · Ducted2.0076%9.520.510.536,600CEE 25CEE 26XcelES CC338215933982
962(C,H,T)5H3V60*K*AAA*KENMORE · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716BCarrier4.5 tons56,000 Btu/h · Ducted2.1075%8.518.011.045,500CEE 25CEE 26XcelES CC186215931662
963249VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler FT5AN(B,X)C36LCarrier2 tons23,400 Btu/h · Ducted2.0287%10.018.514.021,200CEE 25CEE 26XcelES CC1,165217950372
964249VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler F55AA*B36LCarrier3 tons33,600 Btu/h · Ducted2.1877%9.015.212.024,800CEE 25CEE 26XcelES CC879217928529
965249VAN048**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler FT5ANBD60LCarrier4 tons46,000 Btu/h · Ducted2.3275%10.019.012.536,000CEE 25CEE 26XcelES CC573217914936
966249VAN060**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler F55AA*D60LCarrier4.5 tons56,000 Btu/h · Ducted2.1670%9.016.011.740,000CEE 25CEE 26XcelES CC401217933355
96727SCA524A**30*CARRIERwith indoor coil C(A,C,D,E)24A3J+TDR and furnace 59TP6C100V21**20Carrier1.5 tons20,600 Btu/h · Ducted2.6972%7.514.311.215,300CEE 25CEE 26Xcel2,705217178131
96827VNA024A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNXB24L*+UICarrier2 tons23,400 Btu/h · Ducted2.0470%9.017.510.516,600CEE 25CEE 26XcelES CC428215662625
96927VNA036A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC852215670616
97027VNA048A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier4 tons46,500 Btu/h · Ducted2.2070%9.519.510.533,000CEE 25CEE 26XcelES CC416215675343
97127VNA060A*030*CARRIER · Infinity 20 VS Heat Pumpwith indoor coil CVAMA6021XMA*+UI and furnace 58CU*B040C17**12Carrier4.5 tons56,000 Btu/h · Ducted2.1572%8.118.09.543,500CEE 25CEE 26XcelES CC222215682803
97227VNA154A*030*CARRIER · Infinity 21 VS Cold Climate Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 58TN*B090C17**16Carrier4 tons47,000 Btu/h · Ducted2.0898%10.518.511.550,000CEE 25CEE 26XcelES CC482215588077
97327VNA324A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 58CU*B040C17**12Carrier2 tons23,200 Btu/h · Ducted2.1081%9.522.013.022,200CEE 25CEE 26XcelES CC444217624599
97427VNA336A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,000 Btu/h · Ducted2.1075%9.522.012.525,200CEE 25CEE 26XcelES CC629215933964
97527VNA348A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 58CU*A100C21**20Carrier3.5 tons43,500 Btu/h · Ducted2.0076%9.520.510.536,600CEE 25CEE 26XcelES CC346215933974

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 6,515 models; narrow the filters for the rest.