CADET heat pump efficiency: 8 outdoor models compared
CADET has 8 heat pump outdoor models certified with this refrigerant group, in 16 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes CADET makes. CADET has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 8
- AHRI certifications
- 16
- Efficiency index
- 71%
- Typical model vs same-size, same-type peers (12 models)
- Meet CEE 2025
- 100%
- 8 models
How CADET compares with comparable models
- CADET
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index12 models scored | 71% | Not ranked | — |
| COP at 5°F12 models scored | 44% | Not ranked | 2.00 |
| Capacity retention at 5°F12 models scored | 85% | Not ranked | 96% |
| HSPF212 models scored | 81% | Not ranked | 10.5 |
| SEER212 models scored | 68% | Not ranked | 21.5 |
| EER212 models scored | 75% | Not ranked | 12.8 |
| Heating capacity at 5°F12 models scored | 83% | Not ranked | 21,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 8 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 8 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 8 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 100% | 8 |
Sizes and duct types offered
- CADET (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 77% | 63% | 79% | 83% |
| Ducted, 2.5–3 tons | 2 | 81% | 56% | 87% | 86% |
| Ducted, 3.5–4.5 tons | 1 | 84% | 54% | 99% | 96% |
| Non-ducted, up to 1.5 tons | 4 | 71% | 41% | 82% | 68% |
| Non-ducted, 2 tons | 1 | 73% | 51% | 95% | 67% |
| Non-ducted, 2.5–3 tons | 2 | 55% | 26% | 71% | 37% |
| Non-ducted, 3.5–4.5 tons | 1 | 63% | 37% | 57% | 56% |
Every CADET model in the market
- CADET models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top CADET models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1500006879CADET · 500 Series | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 48,000 | 20.4 | CEE 25CEE 26XcelES CC | 3 | 218471394 | Ducted, 3.5–4.5 tons | 82.7 |
| 2500006878CADET · 500 Series | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 38,000 | 19.4 | CEE 25CEE 26XcelES CC | 3 | 218471391 | Ducted, 2.5–3 tons | 82.5 |
| 3500006882CADET · 500 Serieswith ductless indoor unit 500006874 | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 2.00 | 10.8 | 18,000 | 21.7 | CEE 25CEE 26XcelES CC | 1 | 218471382 | Non-ducted, up to 1.5 tons | 78.3 |
| 4500006883CADET · 500 Serieswith ductless indoor unit 500006875 | 2 tons23,000 Btu/h · Non-ducted | 92% | 2.00 | 13.3 | 24,000 | 22.3 | CEE 25CEE 26XcelES CC | 1 | 218471383 | Non-ducted, 2 tons | 77.2 |
| 5500006877CADET · 500 Series | 2.5 tons28,000 Btu/h · Ducted | 96% | 2.00 | 9.5 | 27,000 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 218471388 | Ducted, 2.5–3 tons | 72.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1500006879CADET · 500 Series | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 20.4 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 218471394 | Ducted, 3.5–4.5 tons | 83.9 | 82.7 | 85.1 | 82.7 |
| 2500006878CADET · 500 Series | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 19.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 218471391 | Ducted, 2.5–3 tons | 83.6 | 82.5 | 84.8 | 82.5 |
| 3500006880CADET · 500 Serieswith ductless indoor unit 500006872 | 1 ton9,000 Btu/h · Non-ducted | 96% | 1.80 | 12.5 | 26.0 | 15.0 | CEE 25CEE 26XcelES CC | 1 | 218471380 | Non-ducted, up to 1.5 tons | 79.5 | 65.1 | 93.8 | 65.1 |
| 4500006876CADET · 500 Series | 1.5 tons19,000 Btu/h · Ducted | 90% | 2.00 | 10.0 | 20.0 | 13.0 | CEE 25CEE 26XcelES CC | 3 | 218471385 | Ducted, up to 1.5 tons | 77.4 | 70.8 | 84.0 | 70.8 |
| 5500006877CADET · 500 Series | 2.5 tons28,000 Btu/h · Ducted | 96% | 2.00 | 9.5 | 19.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 218471388 | Ducted, 2.5–3 tons | 77.4 | 72.7 | 82.1 | 72.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | 500006876 | 2.00 | Ducted, up to 1.5 tons | 63% | 218471385 |
| Capacity retention at 5°F | 500006878 | 104% | Non-ducted, 2.5–3 tons | 95% | 218471392 |
| HSPF2 | 500006879 | 11.0 | Ducted, 3.5–4.5 tons | 99% | 218471394 |
| SEER2 | 500006879 | 20.4 | Ducted, 3.5–4.5 tons | 96% | 218471394 |
| EER2 | 500006880 | 15.0 | Non-ducted, up to 1.5 tons | 91% | 218471380 |
| Heating capacity at 5°F | 500006878 | 37,400 Btu/h | Non-ducted, 2.5–3 tons | 94% | 218471392 |
CADET size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 70.8(50 is the typical model of its size class)5000068761 of 1 models qualify · AHRI 218471385 | 77.4(50 is the typical model of its size class)5000068761 of 1 models have all five ratings · AHRI 218471385 |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)5000068782 of 2 models qualify · AHRI 218471391 | 83.6(50 is the typical model of its size class)5000068782 of 2 models have all five ratings · AHRI 218471391 |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)5000068791 of 1 models qualify · AHRI 218471394 | 83.9(50 is the typical model of its size class)5000068791 of 1 models have all five ratings · AHRI 218471394 |
| Non-ducted, up to 1.5 tons | 78.3(50 is the typical model of its size class)500006882with ductless indoor unit 5000068744 of 4 models qualify · AHRI 218471382 | 79.5(50 is the typical model of its size class)500006880with ductless indoor unit 5000068724 of 4 models have all five ratings · AHRI 218471380 |
| Non-ducted, 2 tons | 77.2(50 is the typical model of its size class)500006883with ductless indoor unit 5000068751 of 1 models qualify · AHRI 218471383 | 72.9(50 is the typical model of its size class)500006883with ductless indoor unit 5000068751 of 1 models have all five ratings · AHRI 218471383 |
| Non-ducted, 2.5–3 tons | 72.6(50 is the typical model of its size class)5000068782 of 2 models qualify · AHRI 218471392 | 66.3(50 is the typical model of its size class)5000068782 of 2 models have all five ratings · AHRI 218471390 |
| Non-ducted, 3.5–4.5 tons | 68.7(50 is the typical model of its size class)5000068791 of 1 models qualify · AHRI 218471395 | 62.6(50 is the typical model of its size class)5000068791 of 1 models have all five ratings · AHRI 218471393 |
Newest CADET certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| 500006879CADET · 500 Series | 4 tons46,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 99% | 10.6 | 20.8 | CEE 25CEE 26XcelES CC | 3 | 218471395 |
| 500006878CADET · 500 Series | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.95 | 104% | 10.9 | 20.5 | CEE 25CEE 26XcelES CC | 3 | 218471392 |
| 500006877CADET · 500 Series | 2.5 tons27,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.95 | 99% | 9.8 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 218471389 |
| 500006876CADET · 500 Series | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 90% | 10.0 | 20.5 | CEE 25CEE 26XcelES CC | 3 | 218471386 |
| 500006883CADET · 500 Serieswith ductless indoor unit 500006875 | 2 tons23,000 Btu/h · Non-ducted | 2.00 | 92% | 13.3 | 22.3 | CEE 25CEE 26XcelES CC | 1 | 218471383 |
Compare CADET
CADET includes these brand names as listed in AHRI: CADET. Standards are checked against published thresholds; program rules beyond ratings are not checked.