- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
12,326 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 9826RP15AY42AJ2NRUUDwith ducted air handler AE*L+CM59A4J+TDR | Rheem | 3 tons37,600 Btu/h · Ducted | 3.06 | 130% | 7.5 | 15.2 | 11.7 | 50,000 | CEE 25CEE 26XcelES CC | 828 | 216438506 |
| 9827RP15AY48AC2NRHEEMwith ducted air handler RH2TY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216011653 |
| 9828RP15AY48AD2NRHEEMwith ducted air handler RH2TY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216011654 |
| 9829RP15AY48AJ2NRUUDwith ducted air handler AE*L+CM59A4J+TDR | Rheem | 3.5 tons43,000 Btu/h · Ducted | 3.08 | 128% | 7.8 | 15.2 | 11.7 | 56,500 | CEE 25CEE 26XcelES CC | 813 | 216438507 |
| 9830RP15AY60AC2NRHEEMwith ducted air handler RH2TY6024STANN | Rheem | 5 tons57,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 6 | 216011655 |
| 9831RP15AY60AD2NRHEEMwith ducted air handler RH2TY6024STANN | Rheem | 5 tons57,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 6 | 216011656 |
| 9832RP15AY60AJ2NRUUDwith indoor coil D(A,C,E)60D4J+TDR and furnace R801V1005A21UHN | Rheem | 4.5 tons53,000 Btu/h · Ducted | 3.05 | 115% | 7.8 | 15.2 | 11.7 | 64,000 | Xcel | 411 | 217015517 |
| 9833RP17AY24AJVCRHEEM · Classic Pluswith indoor coil RCFY2417STANM and furnace R972V0403A14UDS | Rheem | 2 tons22,400 Btu/h · Ducted | 2.20 | 72% | 8.1 | 16.0 | 11.7 | 16,100 | CEE 25CEE 26XcelES CC | 200 | 218719262 |
| 9834RP17AY36AJVCRUUD · Achiever Pluswith indoor coil RCFY3617STANM and furnace R801V0503A14DZN | Rheem | 3 tons34,200 Btu/h · Ducted | 2.00 | 91% | 9.5 | 16.0 | 10.0 | 31,000 | CEE 25CEE 26XcelES CC | 458 | 218327618 |
| 9835RP17AY48AJVCRHEEM · Classic Pluswith indoor coil RCFY4821STANM and furnace R972V0705A21UPS | Rheem | 3.5 tons44,500 Btu/h · Ducted | 2.10 | 75% | 9.5 | 16.0 | 10.0 | 33,400 | CEE 25CEE 26XcelES CC | 197 | 218719335 |
| 9836RP17AY60AJVCRHEEM · Classic Pluswith ducted air handler RH2TY6024STANN | Rheem | 5 tons57,000 Btu/h · Ducted | 2.00 | 78% | 9.5 | 17.0 | 11.0 | 44,500 | CEE 25CEE 26XcelES CC | 82 | 218160613 |
| 9837RP19AY24AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFY2421HEAAM and furnace R972V0603A17UPS | Rheem | 2 tons22,800 Btu/h · Ducted | 2.10 | 77% | 8.5 | 21.0 | 13.0 | 17,500 | CEE 25CEE 26XcelES CC | 33 | 218728655 |
| 9838RP19AY36AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFY3621MEAAM and furnace R972V0603A17UPS | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 77% | 8.5 | 20.0 | 12.0 | 26,200 | CEE 25CEE 26XcelES CC | 19 | 218728673 |
| 9839RP19AY48AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFY4821SEAAM and furnace R972V0705A21UPS | Rheem | 4 tons45,500 Btu/h · Ducted | 2.20 | 76% | 8.5 | 19.0 | 12.0 | 34,800 | CEE 25CEE 26Xcel | 27 | 218728688 |
| 9840RP19AY60AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFY6021SEAAM and furnace R972V0855A21UPS | Rheem | 4.5 tons53,500 Btu/h · Ducted | 2.10 | 84% | 8.1 | 17.0 | 10.0 | 45,000 | CEE 25CEE 26Xcel | 14 | 218728704 |
| 9841SP14AY18AJ1NSUREwith ducted air handler AE*S+CM24C2J+TDR | Rheem | 1.5 tons15,500 Btu/h · Ducted | 2.30 | 55% | 7.5 | 14.3 | 9.0 | 8,400 | None | 39 | 218338278 |
| 9842SP14AY24AJ2NSUREwith ducted air handler AE*S+CM24C2J+TDR | Rheem | 1.5 tons20,600 Btu/h · Ducted | 2.42 | 56% | 7.5 | 14.3 | 9.0 | 11,800 | None | 46 | 218338279 |
| 9843SP14AY30AJ2NSUREwith ducted air handler AE*S+DM36A3J+TDR | Rheem | 2 tons26,800 Btu/h · Ducted | 2.33 | 58% | 7.5 | 14.3 | 9.0 | 15,200 | None | 71 | 218338280 |
| 9844SP14AY36AC2NSUREwith ducted air handler SH2CY3617STANN | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216011627 |
| 9845SP14AY36AD2NSUREwith ducted air handler SH2CY3617STANN | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216011630 |
| 9846SP14AY36AJ2NSUREwith ducted air handler AE*S+DM36A3J+TDR | Rheem | 2.5 tons32,400 Btu/h · Ducted | 2.54 | 65% | 7.5 | 14.3 | 9.0 | 20,400 | None | 97 | 218338281 |
| 9847SP14AY42AC2NSUREwith ducted air handler SH2CY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216011625 |
| 9848SP14AY42AD2NSUREwith ducted air handler SH2CY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216011626 |
| 9849SP14AY42AJ2NSUREwith ducted air handler AE*L+CM59A4J+TDR | Rheem | 3 tons37,600 Btu/h · Ducted | 2.56 | 61% | 7.5 | 14.3 | 9.0 | 24,200 | None | 95 | 218338282 |
| 9850SP14AY48AC2NSUREwith ducted air handler SH2CY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216011628 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,326 models; narrow the filters for the rest.