Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
12,326 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 9876SP19AY36AJVCSURE · VANTIXwith indoor coil TCFY3621MEAAM and furnace S972V0603A17UPS | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 77% | 8.5 | 20.0 | 12.0 | 26,200 | CEE 25CEE 26XcelES CC | 19 | 218728680 |
| 9877SP19AY48AJVCSURE · VANTIXwith indoor coil TCFY4821SEAAM and furnace S972V0705A21UPS | Rheem | 4 tons45,500 Btu/h · Ducted | 2.20 | 76% | 8.5 | 19.0 | 12.0 | 34,800 | CEE 25CEE 26Xcel | 17 | 218728695 |
| 9878SP19AY60AJVCSURE · VANTIXwith indoor coil TCFY6021SEAAM and furnace S972V0855A21UPS | Rheem | 4.5 tons53,500 Btu/h · Ducted | 2.10 | 84% | 8.1 | 17.0 | 10.0 | 45,000 | CEE 25CEE 26Xcel | 14 | 218728709 |
| 9879UP19AY24AJVCRUUD · ULTRA SERIESwith indoor coil RCFY2421HEAAM and furnace R972V0603A17UPS | Rheem | 2 tons22,800 Btu/h · Ducted | 2.10 | 77% | 8.5 | 21.0 | 13.0 | 17,500 | CEE 25CEE 26XcelES CC | 41 | 218728656 |
| 9880UP19AY36AJVCRUUD · ULTRA SERIESwith indoor coil RCFY3621MEAAM and furnace R972V0603A17UPS | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 77% | 8.5 | 20.0 | 12.0 | 26,200 | CEE 25CEE 26XcelES CC | 27 | 218728674 |
| 9881UP19AY48AJVCRUUD · ULTRA SERIESwith indoor coil RCFY4821SEAAM and furnace R972V0705A21UPS | Rheem | 4 tons45,500 Btu/h · Ducted | 2.20 | 76% | 8.5 | 19.0 | 12.0 | 34,800 | CEE 25CEE 26Xcel | 20 | 218728689 |
| 9882UP19AY60AJVCRUUD · ULTRA SERIESwith indoor coil RCFY6021SEAAM and furnace R972V0855A21UPS | Rheem | 4.5 tons53,500 Btu/h · Ducted | 2.10 | 84% | 8.1 | 17.0 | 10.0 | 45,000 | CEE 25CEE 26Xcel | 18 | 218728705 |
| 9883WP14AY18AJ1NRHEEMwith indoor coil D(A,C,E)24B3J+TDR and furnace R801V0754A17DZ | Rheem | 1.5 tons16,400 Btu/h · Ducted | 2.40 | 57% | 7.5 | 14.8 | 11.7 | 9,700 | None | 227 | 215408163 |
| 9884WP14AY24AJ2NRHEEMwith indoor coil D(A,C,E)24B3J+TDR and furnace R921V0603A17M4 | Rheem | 2 tons21,800 Btu/h · Ducted | 2.43 | 59% | 7.5 | 14.3 | 9.0 | 13,400 | None | 208 | 215408200 |
| 9885WP14AY30AJ2NRUUDwith ducted air handler AE*S+CM30C2J+TDR | Rheem | 2 tons25,200 Btu/h · Ducted | 2.43 | 59% | 7.5 | 14.3 | 8.0 | 16,400 | None | 377 | 216438556 |
| 9886WP14AY36AC2NRHEEM · VERSUSwith ducted air handler RH2TY3617STANN | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551695 |
| 9887WP14AY36AD2NRHEEM · VERSUSwith ducted air handler RH2TY3617STANN | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551702 |
| 9888WP14AY36AJ2NRUUDwith ducted air handler AE*S+CM36B2J+TDR | Rheem | 2.5 tons30,400 Btu/h · Ducted | 2.66 | 66% | 7.5 | 14.3 | 8.0 | 21,800 | None | 459 | 216438559 |
| 9889WP14AY42AC2NRHEEMwith ducted air handler RH2TY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216011615 |
| 9890WP14AY42AD2NRHEEMwith ducted air handler RH2TY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216011617 |
| 9891WP14AY42AJ2NRHEEMwith indoor coil D(A,C,E)60C3J+TDR and furnace R801T1505A24UH | Rheem | 3 tons38,500 Btu/h · Ducted | 2.67 | 60% | 7.5 | 14.5 | 9.0 | 23,400 | None | 480 | 215408384 |
| 9892WP14AY48AC2NRHEEM · VERSUSwith ducted air handler RH2TY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551697 |
| 9893WP14AY48AD2NRHEEM · VERSUSwith ducted air handler RH2TY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551704 |
| 9894WP14AY48AJ2NWEATHERKINGwith indoor coil D(A,C,E)48B4J+TDR and furnace W801W1005A21DZ | Rheem | 3.5 tons43,500 Btu/h · Ducted | 2.50 | 61% | 7.8 | 15.2 | 10.5 | 27,400 | None | 481 | 217559376 |
| 9895WP14AY60AC2NRHEEM · VERSUSwith ducted air handler RH2TY6021STANA | Rheem | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551699 |
| 9896WP14AY60AD2NRHEEM · VERSUSwith ducted air handler RH2TY6021STANA | Rheem | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551706 |
| 9897WP14AY60AJ2NWEATHERKINGwith indoor coil D(A,C,E)60B4J+TDR and furnace W801W1005A21UHN | Rheem | 4.5 tons51,500 Btu/h · Ducted | 2.60 | 58% | 7.8 | 15.2 | 11.2 | 32,000 | None | 294 | 217228066 |
| 9898WP15AY18AJ2NWEATHERKINGwith ducted air handler PE(S,T)28J | Rheem | 1.5 tons16,300 Btu/h · Ducted | 2.68 | 125% | 7.5 | 14.5 | 11.5 | 21,200 | XcelES CC | 86 | 216591940 |
| 9899WP15AY24AJ2NWEATHERKINGwith ducted air handler PE(S,T)28J | Rheem | 2 tons21,400 Btu/h · Ducted | 2.80 | 125% | 7.5 | 14.5 | 11.5 | 28,000 | None | 156 | 216591941 |
| 9900WP15AY30AJ2NWEATHERKINGwith ducted air handler PE(S,T)34J | Rheem | 2 tons25,800 Btu/h · Ducted | 2.63 | 129% | 7.5 | 15.2 | 11.7 | 34,000 | Xcel | 307 | 217735640 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,326 models; narrow the filters for the rest.