Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

12,326 models

Sorted by manufacturer and model.
Page 406 of 494
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
10126AC030DXADCGSAMSUNG · 4-Way Cassette (WindFree™) Standard (CAC)with ductless indoor unit AC030DN4DCGSamsung2.5 tons30,000 Btu/h · Ducted and non-ducted1.8080%9.521.712.027,200CEE 25CEE 26XcelES CC3215490144
10127AC030DXSCCGSAMSUNG · 4-Way Cassette (WindFree™) Premium (CAC)with ductless indoor unit AC030DN4DCGSamsung2.5 tons30,000 Btu/h · Ducted and non-ducted1.80100%10.722.814.434,000CEE 25CEE 26XcelES CC5215385454
10128AC036DXADCGSAMSUNG · 4-Way Cassette (WindFree™) Standard (CAC)with ductless indoor unit AC036DN4DCGSamsung3 tons36,000 Btu/h · Ducted and non-ducted1.8080%9.219.511.032,000CEE 25CEE 26XcelES CC3215490145
10129AC036DXSCCGSAMSUNG · 4-Way Cassette (WindFree™) Premium (CAC)with ductless indoor unit AC036DN4DCGSamsung3 tons36,000 Btu/h · Ducted and non-ducted1.80100%10.622.013.540,000CEE 25CEE 26XcelES CC5215385457
10130AC036FCUDCGSAMSUNG · Hylex - Standardwith ducted air handler H,YG35*36+TXVSamsung3 tons33,000 Btu/h · Ducted1.9275%8.014.39.525,600XcelES CC44217730543
10131AC036FCUPCGSAMSUNGwith ducted air handler CV362B*A+TXV+AEF48BXPSamsung3 tons34,000 Btu/h · Ducted2.38111%8.417.012.037,200CEE 25CEE 26XcelES CC52217993392
10132AC048DXADCGSAMSUNG · 4-Way Cassette (WindFree™) Standard (CAC)with ductless indoor unit AC048DN4DCGSamsung4 tons48,000 Btu/h · Ducted and non-ducted1.8081%9.018.59.044,000XcelES CC3215490146
10133AC048DXSCCGSAMSUNG · 4-Way Cassette (WindFree™) Premium (CAC)with ductless indoor unit AC048DN4DCGSamsung4 tons48,000 Btu/h · Ducted and non-ducted1.80100%10.420.012.254,000CEE 25CEE 26XcelES CC4215385460
10134AC048FCUDCGSAMSUNGwith ducted air handler L(E,G)M60AJSamsung3.5 tons44,000 Btu/h · Ducted2.4853%7.814.39.525,000ES CC40218361333
10135AC048FCUPCGSAMSUNGwith ducted air handler CH606C*C+TXV+AEF60CXPSamsung4 tons46,500 Btu/h · Ducted2.4077%8.516.010.535,600CEE 25CEE 26XcelES CC18217993424
10136AC060FCUDCGSAMSUNG · Hylex - Standardwith ducted air handler FE*TT7*60+TXVSamsung4.5 tons54,000 Btu/h · Ducted2.0173%8.014.310.041,000XcelES CC36217730551
10137AC060FCUPCGSAMSUNG · Hylex - Premiumwith ducted air handler FEMUU1A60S001RSamsung4.5 tons55,000 Btu/h · Ducted1.9877%9.017.010.843,000CEE 25CEE 26XcelES CC6217734250
10138AJ020DXJ2CGSAMSUNG · FJM (Standard)Samsung1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8170%9.020.012.715,500CEE 25CEE 26Xcel3216372791
10139AJ020DXS3CGSAMSUNG · FJM (Premium)Samsung2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95100%10.523.015.022,000CEE 25CEE 26XcelES CC3216372795
10140AJ024DXJ3CGSAMSUNG · FJM (Standard)Samsung2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8166%9.522.512.716,500CEE 25CEE 263216372790
10141AJ024DXS4CGSAMSUNG · FJM (Premium)Samsung2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.85100%10.423.014.625,000CEE 25CEE 26XcelES CC3216372794
10142AJ030DXS4CGSAMSUNG · FJM (Premium)Samsung2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.81100%10.022.513.528,600CEE 25CEE 26XcelES CC3216372793
10143AJ036DXJ4CGSAMSUNG · FJM (Standard)Samsung2.5 tons32,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8173%9.522.512.526,400CEE 25CEE 26Xcel3216372789
10144AJ036DXS4CGSAMSUNG · FJM (Premium)Samsung3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.04100%9.521.512.536,600CEE 25CEE 26XcelES CC3216372792
10145AJ048DXJ5CGSAMSUNG · FJM (Standard)Samsung4 tons46,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8165%9.021.011.731,400CEE 25CEE 263216372788
10146AM024HCMDCGSAMSUNG · DVM S MiniSamsung2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1889%10.726.017.024,000CEE 25CEE 26XcelES CC3218717190
10147AM036FCMDCGSAMSUNG · DVM S MiniSamsung3 tons38,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1279%11.022.013.533,210CEE 25CEE 26XcelES CC3216032693
10148AM036HCMDCSSAMSUNG · DVM S MiniSamsung3 tons38,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1279%11.022.013.533,210CEE 25CEE 26XcelES CC3218399249
10149AM048FCMDCGSAMSUNG · DVM S MiniSamsung4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0281%10.521.312.443,470CEE 25CEE 26XcelES CC3216032694
10150AM048HCMDCSSAMSUNG · DVM S MiniSamsung4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0281%10.521.312.443,470CEE 25CEE 26XcelES CC3218399250

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,326 models; narrow the filters for the rest.