Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

13,619 models

Sorted by manufacturer and model.
Page 436 of 545
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
10876SP17AY60AJVCSURE · NONEwith ducted air handler SH2VY6024STACNRheem5 tons57,000 Btu/h · Ducted2.0078%9.517.010.544,500CEE 25CEE 26XcelES CC52218159984
10877SP19AY24AJVCSURE · VANTIXwith indoor coil TCFY2421HEAAM and furnace S972V0603A17UPSRheem2 tons22,800 Btu/h · Ducted2.1077%8.521.013.017,500CEE 25CEE 26XcelES CC33218728662
10878SP19AY36AJVCSURE · VANTIXwith indoor coil TCFY3621MEAAM and furnace S972V0603A17UPSRheem3 tons34,200 Btu/h · Ducted2.2077%8.520.012.026,200CEE 25CEE 26XcelES CC19218728680
10879SP19AY48AJVCSURE · VANTIXwith indoor coil TCFY4821SEAAM and furnace S972V0705A21UPSRheem4 tons45,500 Btu/h · Ducted2.2076%8.519.012.034,800CEE 25CEE 26Xcel17218728695
10880SP19AY60AJVCSURE · VANTIXwith indoor coil TCFY6021SEAAM and furnace S972V0855A21UPSRheem4.5 tons53,500 Btu/h · Ducted2.1084%8.117.010.045,000CEE 25CEE 26Xcel14218728709
10881UP19AY24AJVCRUUD · ULTRA SERIESwith indoor coil RCFY2421HEAAM and furnace R972V0603A17UPSRheem2 tons22,800 Btu/h · Ducted2.1077%8.521.013.017,500CEE 25CEE 26XcelES CC41218728656
10882UP19AY36AJVCRUUD · ULTRA SERIESwith indoor coil RCFY3621MEAAM and furnace R972V0603A17UPSRheem3 tons34,200 Btu/h · Ducted2.2077%8.520.012.026,200CEE 25CEE 26XcelES CC27218728674
10883UP19AY48AJVCRUUD · ULTRA SERIESwith indoor coil RCFY4821SEAAM and furnace R972V0705A21UPSRheem4 tons45,500 Btu/h · Ducted2.2076%8.519.012.034,800CEE 25CEE 26Xcel20218728689
10884UP19AY60AJVCRUUD · ULTRA SERIESwith indoor coil RCFY6021SEAAM and furnace R972V0855A21UPSRheem4.5 tons53,500 Btu/h · Ducted2.1084%8.117.010.045,000CEE 25CEE 26Xcel18218728705
10885WP14AY18AJ1NRHEEMwith indoor coil D(A,C,E)24B3J+TDR and furnace R801V0754A17DZRheem1.5 tons16,400 Btu/h · Ducted2.4057%7.514.811.79,700None236215408163
10886WP14AY24AJ2NRHEEMwith indoor coil D(A,C,E)24B3J+TDR and furnace R921V0603A17M4Rheem2 tons21,800 Btu/h · Ducted2.4359%7.514.39.013,400None214215408200
10887WP14AY30AJ2NRUUDwith ducted air handler AE*S+CM30C2J+TDRRheem2 tons25,200 Btu/h · Ducted2.4359%7.514.38.016,400None380216438556
10888WP14AY36AC2NRHEEM · VERSUSwith ducted air handler RH2TY3617STANNRheem3 tons34,200 Btu/h · Ducted——7.514.39.0—None4216551695
10889WP14AY36AD2NRHEEM · VERSUSwith ducted air handler RH2TY3617STANNRheem3 tons34,200 Btu/h · Ducted——7.514.39.0—None4216551702
10890WP14AY36AJ2NRUUDwith ducted air handler AE*S+CM36B2J+TDRRheem2.5 tons30,400 Btu/h · Ducted2.6666%7.514.38.021,800None464216438559
10891WP14AY42AC2NRHEEMwith ducted air handler RH2TY4821STANNRheem3.5 tons40,000 Btu/h · Ducted——7.514.39.0—None4216011615
10892WP14AY42AD2NRHEEMwith ducted air handler RH2TY4821STANNRheem3.5 tons40,000 Btu/h · Ducted——7.514.39.0—None4216011617
10893WP14AY42AJ2NRHEEMwith indoor coil D(A,C,E)60C3J+TDR and furnace R801T1505A24UHRheem3 tons38,500 Btu/h · Ducted2.6760%7.514.59.023,400None487215408384
10894WP14AY48AC2NRHEEM · VERSUSwith ducted air handler RH2TY4821STANNRheem4 tons45,500 Btu/h · Ducted——7.514.39.0—None4216551697
10895WP14AY48AD2NRHEEM · VERSUSwith ducted air handler RH2TY4821STANNRheem4 tons45,500 Btu/h · Ducted——7.514.39.0—None4216551704
10896WP14AY48AJ2NWEATHERKINGwith indoor coil D(A,C,E)48B4J+TDR and furnace W801W1005A21DZRheem3.5 tons43,500 Btu/h · Ducted2.5061%7.815.210.527,400None489217559376
10897WP14AY60AC2NRHEEM · VERSUSwith ducted air handler RH2TY6021STANARheem4.5 tons55,000 Btu/h · Ducted——7.514.39.0—None4216551699
10898WP14AY60AD2NRHEEM · VERSUSwith ducted air handler RH2TY6021STANARheem4.5 tons55,000 Btu/h · Ducted——7.514.39.0—None4216551706
10899WP14AY60AJ2NWEATHERKINGwith indoor coil D(A,C,E)60B4J+TDR and furnace W801W1005A21UHNRheem4.5 tons51,500 Btu/h · Ducted2.6058%7.815.211.232,000None343217228066
10900WP15AY18AJ2NWEATHERKINGwith ducted air handler PE(S,T)28JRheem1.5 tons16,300 Btu/h · Ducted2.68125%7.514.511.521,200XcelES CC90216591940

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 13,619 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy