Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
12,326 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 11901PL5E36N00D21YORK | York | 3 tons34,200 Btu/h · Ducted | 1.75 | 61% | 8.1 | 16.0 | 10.0 | 21,000 | None | 5 | 218450382 |
| 11902PL5E60N00D21CHAMPION HEATING AND COOLING · PL5 | York | 5 tons57,000 Btu/h · Ducted | 1.80 | 70% | 8.5 | 16.0 | 9.0 | 40,000 | ES CC | 5 | 218450296 |
| 11903RH418E2S11GUARDIANwith ducted air handler PE(S,T)23J | York | 1.5 tons16,000 Btu/h · Ducted | 2.74 | 57% | 7.5 | 14.3 | 11.0 | 8,500 | None | 396 | 217735305 |
| 11904RH424E2S11GUARDIANwith indoor coil CM30C2K+TDR and furnace E*E**B | York | 2 tons21,200 Btu/h · Ducted | 2.55 | 65% | 7.5 | 14.3 | 10.5 | 14,700 | None | 190 | 217626354 |
| 11905RH430E2S11GUARDIAN · LX SERIESwith ducted air handler JHE30B5AD2SS1 | York | 2.5 tons30,000 Btu/h · Ducted | 2.00 | 53% | 7.5 | 14.3 | 11.0 | 14,600 | None | 63 | 217942059 |
| 11906RH436E2S11GUARDIANwith indoor coil D(A,C,E)36B4J+TDR and furnace TM8Y100C20MP11 | York | 2.5 tons30,200 Btu/h · Ducted | 2.91 | 70% | 7.8 | 14.3 | 9.8 | 21,800 | None | 570 | 217049469 |
| 11907RH436E4S11GUARDIAN · LX SERIESwith ducted air handler CTM48D5CFS1+JME18D2SN1 | York | 3 tons34,200 Btu/h · Ducted | 2.36 | 57% | 7.5 | 14.3 | 11.0 | 17,600 | None | 28 | 217351406 |
| 11908RH448E2S11GUARDIANwith indoor coil D(A,C,E)60D3J+TDR and furnace TM9Y080C16MP11 | York | 3.5 tons43,500 Btu/h · Ducted | 2.91 | 70% | 7.8 | 14.3 | 11.0 | 32,400 | None | 935 | 217049622 |
| 11909RH448E3S11GUARDIAN · LX SERIESwith ducted air handler CTF60C5CHS1+JME12C2SN1 | York | 4 tons46,500 Btu/h · Ducted | 2.36 | 56% | 7.5 | 14.3 | 11.0 | 25,800 | None | 32 | 217291989 |
| 11910RH448E4S11EVCON · LX SERIESwith ducted air handler CTM60D5CHS1+JME18D2SN1 | York | 4 tons48,000 Btu/h · Ducted | 2.36 | 56% | 7.5 | 14.3 | 11.0 | 26,200 | None | 32 | 217351372 |
| 11911RH460E2S11GUARDIANwith ducted air handler AE*L+DM60B4J+TDR | York | 4.5 tons52,000 Btu/h · Ducted | 2.79 | 69% | 7.5 | 14.3 | 11.0 | 39,000 | None | 322 | 217015411 |
| 11912RH460E3S11GUARDIAN · LX SERIESwith ducted air handler CTM60D5CJS1+JME18D2SN1 | York | 4.5 tons55,500 Btu/h · Ducted | 2.34 | 57% | 7.5 | 14.3 | 11.0 | 31,800 | None | 12 | 217292142 |
| 11913RH460E4S11GUARDIAN · LX SERIESwith ducted air handler CTM60D5CJS1+JME18D2SN1 | York | 4.5 tons55,500 Btu/h · Ducted | 2.34 | 57% | 7.5 | 14.3 | 11.0 | 31,800 | None | 12 | 217292218 |
| 11914RH630E2S11GUARDIAN · LX SERIESwith indoor coil CTM36C5ADS1 and furnace RL18080C16MPS1 | York | 2.5 tons30,400 Btu/h · Ducted | 2.40 | 52% | 8.1 | 17.0 | 13.0 | 15,200 | CEE 25CEE 26 | 124 | 218418047 |
| 11915UMC18CN23STG1GUARDIAN · UMULTI | York | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.16 | 104% | 9.4 | 17.5 | 12.0 | 18,800 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 215747714 |
| 11916UMC24CN23STG1GUARDIAN · UMULTI | York | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.88 | 102% | 8.8 | 18.0 | 11.5 | 27,650 | CEE 25CEE 26XcelES CC | 9 | 215747716 |
| 11917UMC36CN23STG1GUARDIAN · UMULTI | York | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.94 | 101% | 10.0 | 22.0 | 12.9 | 36,510 | CEE 25CEE 26XcelES CC | 9 | 215747722 |
| 11918UMC48CN23STG1GUARDIAN · UMULTI | York | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 79% | 9.5 | 22.0 | 12.0 | 37,830 | CEE 25CEE 26XcelES CC | 9 | 215747719 |
| 11919UPC09CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI09HW23STG1 | York | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.80 | 111% | 10.5 | 22.0 | 12.0 | 10,000 | CEE 25CEE 26XcelES CC | 9 | 215439626 |
| 11920UPC12CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI12HW23STG1 | York | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.88 | 100% | 10.5 | 22.0 | 12.0 | 12,000 | CEE 25CEE 26XcelES CC | 9 | 215439627 |
| 11921UPC18CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI18CS23STG1 | York | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.26 | 100% | 10.0 | 20.0 | 12.0 | 18,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 216019852 |
| 11922UPC24CN23STG1GUARDIANwith ducted air handler JHE24B5AC2SS1 | York | 2 tons24,000 Btu/h · Ducted and non-ducted | 3.55 | 81% | 9.5 | 18.0 | 11.7 | 24,200 | CEE 25CEE 26XcelES CC | 32 | 216409634 |
| 11923UPC36CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI36CS23STG1 | York | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.07 | 100% | 9.5 | 19.5 | 12.0 | 36,000 | CEE 25CEE 26XcelES CC | 20 | 215449562 |
| 11924UPC36CN23STG1*GUARDIAN · UPACwith ductless indoor unit UNI36HW23STG1 | York | 3 tons36,000 Btu/h · Non-ducted | 1.88 | 100% | 10.0 | 20.0 | 12.0 | 36,000 | CEE 25CEE 26XcelES CC | 3 | 216346013 |
| 11925UPC48CN23STG1GUARDIAN · UPACwith ducted air handler UNI48DT23STG1 | York | 3.5 tons44,000 Btu/h · Ducted and non-ducted | 2.00 | 100% | 9.5 | 19.5 | 10.7 | 44,000 | CEE 25CEE 26XcelES CC | 15 | 215441405 |