- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
13,619 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 121765HCL5036B1TRANE · F Serieswith ducted air handler 5TDM5B03AC21 | Trane | 2 tons24,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 18.0 | 12.0 | 24,000 | CEE 25CEE 26XcelES CC | 60 | 217500296 |
| 121775HCL5060A1TRANE · 5HCL5 Cold Climatewith ducted air handler 5TEM5D06AC41 | Trane | 4 tons48,000 Btu/h · Ducted | 1.85 | 88% | 9.4 | 17.0 | 10.8 | 42,000 | CEE 25CEE 26Xcel | 4 | 216772257 |
| 121785HCL5060B1TRANE · F Serieswith ducted air handler 5DXCD008AC3 | Trane | 4 tons47,000 Btu/h · Ducted | 1.85 | 98% | 8.8 | 16.0 | 11.0 | 47,000 | CEE 25CEE 26XcelES CC | 20 | 217500298 |
| 121795HPL5024A1AMERICAN STANDARDwith ducted air handler L(E,G)M36GJ | Trane | 2 tons22,000 Btu/h · Ducted | 2.09 | 110% | 8.1 | 16.0 | 11.7 | 25,200 | CEE 25CEE 26XcelES CC | 248 | 217106836 |
| 121805HPL5024A1000AATRANE · 5HPL5with ducted air handler 5TEM6B02AV21+TDR | Trane | 2 tons23,000 Btu/h · Ducted | 1.75 | 78% | 8.1 | 16.0 | 11.7 | 18,000 | CEE 25CEE 26XcelES CC | 15 | 216374485 |
| 121815HPL5036A1AMERICAN STANDARDwith ducted air handler L(E,G)M36JJ | Trane | 2.5 tons32,000 Btu/h · Ducted | 2.08 | 105% | 8.1 | 16.0 | 11.7 | 35,600 | CEE 25CEE 26XcelES CC | 223 | 217106837 |
| 121825HPL5036A1000AATRANE · 5HPL5with ducted air handler 5TEM6D04AV31+TDR | Trane | 3 tons34,000 Btu/h · Ducted | 1.75 | 79% | 8.1 | 16.0 | 11.7 | 27,000 | CEE 25CEE 26XcelES CC | 14 | 216374486 |
| 121835HPL5048A1AMERICAN STANDARDwith ducted air handler L(E,G)M60DJ | Trane | 3.5 tons42,000 Btu/h · Ducted | 2.03 | 104% | 7.8 | 15.2 | 11.2 | 49,500 | CEE 25CEE 26XcelES CC | 360 | 217106838 |
| 121845HPL5048A1*TRANEwith ducted air handler 5PXCBD06AS3+P0V0B000M40SD | Trane | 3.5 tons41,000 Btu/h · Ducted | 1.80 | 82% | 8.1 | 15.2 | 10.8 | 37,000 | Xcel | 18 | 218080537 |
| 121855HPL5048A1000AATRANE · 5HPL5with ducted air handler 5TEM6D06AV41+TDR | Trane | 4 tons46,000 Btu/h · Ducted | 1.75 | 79% | 8.1 | 16.0 | 11.7 | 38,000 | CEE 25CEE 26XcelES CC | 14 | 216374488 |
| 121865HPL5060A1AMERICAN STANDARDwith ducted air handler L(E,G)M60DJ | Trane | 4 tons47,000 Btu/h · Ducted | 1.89 | 102% | 7.5 | 15.2 | 9.0 | 54,000 | Xcel | 17 | 217106839 |
| 121875TCV0X36A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TAMXD05AV41 | Trane | 2.5 tons29,000 Btu/h · Ducted | 2.31 | 110% | 10.3 | 20.2 | 12.7 | 36,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 39 | 218868827 |
| 121885TCV0X48A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TAMXD05AV41 | Trane | 3 tons35,800 Btu/h · Ducted | 2.02 | 104% | 9.7 | 18.4 | 12.0 | 48,000 | CEE 25CEE 26XcelES CC | 43 | 218868907 |
| 121895TCV0X60A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,500 Btu/h · Ducted | 2.05 | 87% | 9.4 | 19.2 | 11.5 | 48,000 | CEE 25CEE 26XcelES CC | 30 | 218792279 |
| 121905TCV0X61A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,000 Btu/h · Ducted | 2.22 | 100% | 10.0 | 18.0 | 11.5 | 55,500 | CEE 25CEE 26CEE AdvXcelDOEES CC | 22 | 218792281 |
| 121915TWA4036A3TRANEwith indoor coil DH60T4J and furnace L8V1B080U4VSB | Trane | 3 tons33,200 Btu/h · Ducted | 2.50 | 68% | 7.8 | 14.3 | 12.0 | 21,400 | CEE 25CEE 26 | 880 | 217211380 |
| 121925TWA4036A4TRANEwith indoor coil DH60T4J and furnace L8V1B080U4VSB | Trane | 3 tons33,200 Btu/h · Ducted | 2.50 | 68% | 7.8 | 14.3 | 12.0 | 21,400 | CEE 25CEE 26 | 880 | 217211786 |
| 121935TWA4042A3TRANEwith indoor coil DH60T4J and furnace *UHMC100CCV4 | Trane | 3.5 tons39,500 Btu/h · Ducted | 2.19 | 60% | 7.5 | 15.2 | 12.0 | 23,600 | CEE 25 | 459 | 217209472 |
| 121945TWA4042A4TRANEwith indoor coil DH60T4J and furnace *UHMC100CCV4 | Trane | 3.5 tons39,500 Btu/h · Ducted | 2.19 | 60% | 7.5 | 15.2 | 12.0 | 23,600 | CEE 25 | 440 | 217209589 |
| 121955TWA4048A3TRANEwith indoor coil DH60T4J and furnace S9X1D120U5PSB | Trane | 4 tons45,500 Btu/h · Ducted | 2.33 | 64% | 8.1 | 15.5 | 12.0 | 28,600 | CEE 25CEE 26 | 592 | 217209817 |
| 121965TWA4048A4TRANEwith indoor coil DH60T4J and furnace S9X1D120U5PSB | Trane | 4 tons45,500 Btu/h · Ducted | 2.33 | 64% | 8.1 | 15.5 | 12.0 | 28,600 | CEE 25CEE 26 | 589 | 217209944 |
| 121975TWA4060A3TRANEwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4.5 tons56,000 Btu/h · Ducted | 2.22 | 51% | 7.8 | 15.2 | 12.0 | 26,600 | None | 247 | 218788202 |
| 121985TWA4060A4TRANEwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4.5 tons56,000 Btu/h · Ducted | 2.22 | 51% | 7.8 | 15.2 | 12.0 | 26,600 | None | 242 | 218788204 |
| 121995TWR4018A1TRANEwith indoor coil DH36T4J and furnace *UHMB080CCV3 | Trane | 1.5 tons18,000 Btu/h · Ducted | 2.66 | 67% | 7.5 | 14.3 | 11.7 | 9,800 | None | 661 | 216939244 |
| 122005TWR4024A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace *UHMC100CCV4 | Trane | 2 tons22,000 Btu/h · Ducted | 2.82 | 67% | 7.5 | 14.3 | 11.2 | 14,200 | None | 1,328 | 216794881 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 13,619 models; narrow the filters for the rest.