Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

7,174 models

Sorted by manufacturer and model.
Page 61 of 287
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1501CH-PQ48-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ48AHUCooper&Hunter4 tons48,000 Btu/h · Ducted2.00100%9.517.512.048,000CEE 25CEE 26XcelES CC9215864124
1502CH-PQ55-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ55AHUCooper&Hunter4.5 tons54,000 Btu/h · Ducted1.9098%9.517.512.054,000CEE 25CEE 26XcelES CC6215864125
1503CH-R18MES-230VOCooper&Hunter · CH SeriesCooper&Hunter1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.613.014,000CEE 25CEE 26XcelES CC3215864256
1504CH-R28MES-230VOCooper&Hunter · CH SeriesCooper&Hunter2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.013.019,000CEE 25CEE 26XcelES CC3215864257
1505CH-R36LCU-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH36LCCTCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.09.626,600CEE 25CEE 26XcelES CC5215864198
1506CH-R36MES-230VOCooper&Hunter · CH SeriesCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC3215864260
1507CH-R48LCU-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RSH48LCCTCooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted2.0076%9.817.110.038,000CEE 25CEE 26XcelES CC5215864199
1508CH-R48MES-230VOCooper&Hunter · CH SeriesCooper&Hunter4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.412.038,000CEE 25CEE 26XcelES CC3215864264
1509CH-RES06-115VOCooper&Hunter · CH Serieswith ductless indoor unit CH-R06OLVWM-115VICooper&Hunter1 ton9,000 Btu/h · Non-ducted2.2173%10.724.515.07,300CEE 25CEE 26XcelES CC1215864144
1510CH-RES09-115VOCooper&Hunter · CH Serieswith ductless indoor unit CH-R09OLVWM-115VICooper&Hunter1 ton9,000 Btu/h · Non-ducted2.2173%10.724.515.07,300CEE 25CEE 26XcelES CC2215864145
1511CH-RES09-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO09MASTWM-230VICooper&Hunter1 ton9,000 Btu/h · Ducted and non-ducted2.3780%12.525.814.98,000CEE 25CEE 26XcelES CC10215864168
1512CH-RES12-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH12MMCCooper&Hunter1 ton12,000 Btu/h · Ducted and non-ducted2.5174%11.024.612.78,900CEE 25CEE 26XcelES CC10215864236
1513CH-RES18-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-R18MOLVWM-230VICooper&Hunter1.5 tons18,000 Btu/h · Ducted and non-ducted2.3572%11.124.013.513,000CEE 25CEE 26XcelES CC11215864149
1514CH-RES24-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO24MASTWM-230VICooper&Hunter2 tons24,000 Btu/h · Ducted and non-ducted2.5478%11.723.014.019,600CEE 25CEE 26XcelES CC9215864171
1515CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS06MDT-MSCooper&Hunter0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.414.47,800CEE 25CEE 26CEE AdvXcelDOEES CC7215864212
1516CH-RHP09-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS09MDT-MSCooper&Hunter1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.413.411,200CEE 25CEE 26XcelES CC10215864213
1517CH-RHP12-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH09-12MCTCooper&Hunter1 ton12,000 Btu/h · Ducted and non-ducted1.9996%11.622.212.511,500CEE 25CEE 26XcelES CC10215864189
1518CH-RHP15-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RH15MASTWM-230VICooper&Hunter1.5 tons18,000 Btu/h · Non-ducted1.92100%11.021.412.518,000CEE 25CEE 26XcelES CC2216763039
1519CH-RHP18-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS18MAHUCooper&Hunter1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.018.012.018,000CEE 25CEE 26XcelES CC11215864126
1520CH-RHP19M-230VOC&H · CH SeriesCooper&Hunter1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.015.019,000CEE 25CEE 26XcelES CC3217155426
1521CH-RHP24-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO24MASTWM-230VICooper&Hunter2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.013.024,200CEE 25CEE 26XcelES CC9215864176
1522CH-RHP28M-230VOC&H · CH SeriesCooper&Hunter2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3217155429
1523CH-RHP33-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO33HASTWM-230VICooper&Hunter3 tons33,000 Btu/h · Non-ducted1.9897%10.519.512.035,000CEE 25CEE 26XcelES CC3216706044
1524CH-RHP36LCU-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS36LCDT-HSCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted2.1090%11.117.712.037,600CEE 25CEE 26XcelES CC5215864220
1525CH-RHP36M-230VOC&H · CH SeriesCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.013.036,000CEE 25CEE 26XcelES CC3217155432

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 7,174 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter