Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

13,619 models

Sorted by manufacturer and model.
Page 76 of 545
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1876(C,H,T)5H6S48*K*AAA*KENMORE · MAINLINE 16 SEER2 HPwith ducted air handler FHMA5*60L*DCarrier4 tons46,500 Btu/h · Ducted2.3052%7.815.212.524,400None205214165200
1877(C,H,T)5H6S60*K*AAA*KENMORE · MAINLINE 16 SEER2 HPwith ducted air handler FTMA5B60L0DCarrier5 tons57,000 Btu/h · Ducted2.1851%7.815.212.528,400None5214602009
1878(C,H,T)5H8T24*K*AAA*KENMORE · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *80MSU0401712ACarrier2 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 251,032216366446
1879(C,H,T)5H8T36*K*AAA*KENMORE · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *97VTN1002122ACarrier3 tons36,000 Btu/h · Ducted2.4051%8.515.012.019,200CEE 25CEE 26840216357661
1880(C,H,T)5H8T48*K*AAA*KENMORE · Mainline 18 SEER2 HPwith ducted air handler FTMA5B60L0DCarrier4 tons48,500 Btu/h · Ducted2.3451%8.118.013.524,600CEE 25CEE 26586216152752
1881(C,H,T)5H8T60*K*AAA*KENMORE · Mainline 18 SEER2 HPwith indoor coil EVM5X61M24A*+WALLCON and furnace *80CSU0802120BCarrier4.5 tons55,500 Btu/h · Ducted2.3652%8.515.512.030,800CEE 25CEE 26423216346852
1882235SAE036**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FJ5AN*C48LCarrier3 tons36,800 Btu/h · Ducted2.2048%8.016.013.017,400CEE 25148217033613
1883235SAE048**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FJ5AN*D60LCarrier4 tons48,500 Btu/h · Ducted2.2550%7.815.212.024,400None20217033788
1884235SAE060**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FJ5AN*D60LCarrier5 tons57,500 Btu/h · Ducted2.1052%7.514.512.028,600None6217028423
1885235SAN018**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)27JCarrier1.5 tons16,600 Btu/h · Ducted2.5055%7.515.211.79,800None1,226216598656
1886235SAN019**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith indoor coil CAA**2517AM and furnace 927TA36060V14Carrier1.5 tons19,000 Btu/h · Ducted1.9643%8.015.513.08,400None2217990207
1887235SAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)34JCarrier2 tons21,400 Btu/h · Ducted2.7065%7.515.212.014,700CEE 25CEE 262,542216598658
1888235SAN030**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons27,000 Btu/h · Ducted2.6657%7.515.212.016,500None1,273216598661
1889235SAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons32,400 Btu/h · Ducted2.6160%7.514.311.721,000CEE 252,426216598662
1890235SAN042**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler L(E,G)M48FJCarrier3.5 tons42,000 Btu/h · Ducted2.6560%7.814.812.023,400None1,153216790322
1891235SAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+CM59A4J+TDRCarrier3.5 tons44,000 Btu/h · Ducted2.7061%7.514.811.728,400None1,060215827990
1892235SAN060**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+DM60B4J+TDRCarrier4.5 tons53,500 Btu/h · Ducted2.6064%7.514.311.734,800None21215827991
1893235SAP036**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FMA5X36**ALCarrier3 tons35,000 Btu/h · Ducted2.2048%7.815.512.517,100None139217033511
1894235SAP048**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FT5ANBD60LCarrier4 tons47,500 Btu/h · Ducted2.2549%7.815.512.023,600None23217033767
1895235SAP060**AA*BRYANT HEATING AND COOLING SYSTEMS · LEGACY 15 SEER2 HPwith ducted air handler FJ5AN*D60LCarrier5 tons57,500 Btu/h · Ducted2.1052%7.514.512.028,600None6217028392
1896246SAN018**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)27JCarrier1.5 tons16,600 Btu/h · Ducted2.5055%7.515.211.79,800None1,190216598664
1897246SAN019**AA*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED 16 SEER2 HPwith indoor coil CAA**1917AM and furnace 82*TB48070V17Carrier1.5 tons19,200 Btu/h · Ducted2.0043%8.015.513.08,400None816217683720
1898246SAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)34JCarrier2 tons21,400 Btu/h · Ducted2.7065%7.515.212.014,700CEE 25CEE 262,467216598666
1899246SAN030**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38JCarrier2.5 tons27,000 Btu/h · Ducted2.6657%7.515.212.016,500None1,191216598669
1900246SAN031**AA*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED 16 SEER2 HPwith indoor coil CAA**3721AM and furnace 83*CB36040C17Carrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 25840217680504

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 13,619 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter