Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

12,335 models

Sorted by manufacturer and model.
Page 80 of 494
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1976B5H6S31*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith indoor coil EA*5X37M21A*+WALLCON and furnace *80CSU0401712BCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 255,257218188957
1977B5H6S36*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FHMA5*48L*CCarrier3 tons36,400 Btu/h · Ducted2.2450%7.815.513.017,500None5,762218192493
1978B5H6S42*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FHMA5*60L*DCarrier3.5 tons42,500 Btu/h · Ducted2.2649%7.815.211.719,900None1,206218188799
1979B5H6S48*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FHMA5*60L*DCarrier4 tons46,500 Btu/h · Ducted2.3052%7.815.212.524,400None1,059218188898
1980B5H6S60*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FTMA5B60L0DCarrier5 tons57,000 Btu/h · Ducted2.1851%7.815.212.528,400None43218188948
1981C5H0V24*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5X24L0B*+WALLCONCarrier2 tons23,400 Btu/h · Ducted2.0468%9.017.510.516,600CEE 25CEE 26XcelES CC1,256215662826
1982C5H0V36*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier3 tons35,400 Btu/h · Ducted2.0472%9.519.511.524,400CEE 25CEE 26XcelES CC2,526215670621
1983C5H0V48*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier4 tons46,500 Btu/h · Ducted2.2070%9.519.510.533,000CEE 25CEE 26XcelES CC1,231215675348
1984C5H0V60*K*AAA*COMFORTMAKER · SoftSound 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONCarrier5 tons57,500 Btu/h · Ducted2.1269%9.020.010.040,500CEE 25CEE 26ES CC596215662892
1985C5H3V36*K*AAA*COMFORTMAKER · SoftSound 23 VS Heat Pumpwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122BCarrier3 tons35,600 Btu/h · Ducted2.1475%9.022.012.528,400CEE 25CEE 26XcelES CC1,827215936669
1986C5H3V48*K*AAA*COMFORTMAKER · SoftSound 23 VS Heat Pumpwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CSU1002120ACarrier3.5 tons43,500 Btu/h · Ducted2.0076%9.520.510.536,600CEE 25CEE 26XcelES CC999215933979
1987C5H3V60*K*AAA*COMFORTMAKER · SoftSound 23 VS Heat Pumpwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716BCarrier4.5 tons56,000 Btu/h · Ducted2.1075%8.518.011.045,500CEE 25CEE 26XcelES CC540215931659
1988C5H6S18*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith ducted air handler FMA5X24**ALCarrier1.5 tons17,400 Btu/h · Ducted2.1046%8.015.512.58,200CEE 251,480214423966
1989C5H6S19*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith indoor coil EA*5X19M17A and furnace *80VTL0701716BCarrier1.5 tons19,200 Btu/h · Ducted2.0043%8.015.513.08,400None1,836217721560
1990C5H6S24*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith ducted air handler FMA5X30**ALCarrier2 tons24,000 Btu/h · Ducted2.2649%8.516.513.011,600CEE 25CEE 263,437214424126
1991C5H6S30*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith indoor coil ESH5X30M12A and furnace *80CTL1102120ACarrier2.5 tons28,400 Btu/h · Ducted2.2646%7.815.512.513,000None1,511214167855
1992C5H6S31*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith indoor coil EA*5X37M21A*+WALLCON and furnace *80CSU0401712BCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.512.013,900CEE 251,953217717188
1993C5H6S36*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith indoor coil EA*5X37M21A and furnace *80VTL1102122ACarrier3 tons35,800 Btu/h · Ducted2.2648%7.816.013.016,900None3,098214161992
1994C5H6S42*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith ducted air handler FHMA5*60L*DCarrier3.5 tons42,500 Btu/h · Ducted2.2649%7.815.211.719,900None678214165280
1995C5H6S48*K*AAA*DAY & NIGHTwith ducted air handler 98-8810+TXV+RDS+TDR+E30B5DCarrier4 tons45,000 Btu/h · Ducted2.3656%7.815.212.524,400None723216618808
1996C5H6S60*K*AAA*COMFORTMAKER · MAINLINE 16 SEER2 HPwith ducted air handler FTMA5B60L0DCarrier5 tons57,000 Btu/h · Ducted2.1851%7.815.212.528,400None22214602006
1997C5H8T24*K*AAA*COMFORTMAKER · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *80MSU0401712ACarrier2 tons23,800 Btu/h · Ducted2.2445%8.518.013.011,100CEE 253,252216366443
1998C5H8T36*K*AAA*COMFORTMAKER · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *97VTN1002122ACarrier3 tons36,000 Btu/h · Ducted2.4051%8.515.012.019,200CEE 25CEE 262,655216357658
1999C5H8T48*K*AAA*COMFORTMAKER · Mainline 18 SEER2 HPwith ducted air handler FTMA5B60L0DCarrier4 tons48,500 Btu/h · Ducted2.3451%8.118.013.524,600CEE 25CEE 261,932216152744
2000C5H8T60*K*AAA*COMFORTMAKER · Mainline 18 SEER2 HPwith indoor coil EVM5X61M24A*+WALLCON and furnace *80CSU0802120BCarrier4.5 tons55,500 Btu/h · Ducted2.3652%8.515.512.030,800CEE 25CEE 261,360216346849