Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

12,335 models

Sorted by manufacturer and model.
Page 83 of 494
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
2051D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2 tons23,800 Btu/h · Ducted2.8879%8.516.09.819,500CEE 25CEE 26XcelES CC5,132217906665
2052D5CUHAH24AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*BCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.011.019,000CEE 25CEE 26XcelES CC4,433218486193
2053D5CUHAH24AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*BCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.011.019,000CEE 25CEE 26XcelES CC4,391217635077
2054D5CUHAH30AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2.5 tons28,000 Btu/h · Ducted2.4880%7.815.29.823,800CEE 25CEE 26XcelES CC1,064217906667
2055D5CUHAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16ACarrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.510.032,200CEE 25CEE 26XcelES CC4,115218490362
2056D5CUHAH30AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16ACarrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.510.032,200CEE 25CEE 26XcelES CC4,261217396826
2057D5CUHAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier3 tons35,000 Btu/h · Ducted2.1474%8.015.210.027,000CEE 25CEE 26XcelES CC204217906668
2058D5CUHAH36AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**ALCarrier3 tons36,200 Btu/h · Ducted1.9079%9.016.510.031,600CEE 25CEE 26XcelES CC3,937218495042
2059D5CUHAH36AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**ALCarrier3 tons36,200 Btu/h · Ducted1.9079%9.016.510.031,600CEE 25CEE 26XcelES CC4,146217486562
2060D5CUHAH48AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDRCarrier4 tons45,000 Btu/h · Ducted2.4375%8.015.29.833,800CEE 25CEE 26XcelES CC224217906669
2061D5CUHAH48AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler F5MA5*60L*DCarrier4 tons47,500 Btu/h · Ducted1.8093%8.514.39.045,000ES CC873218477319
2062D5CUHAH48AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FTMA5B60L0DCarrier4 tons47,500 Btu/h · Ducted1.7690%8.515.28.544,000None32217414362
2063D5CUHAH60AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDRCarrier4 tons45,000 Btu/h · Ducted2.1262%7.515.29.835,800CEE 25CEE 26XcelES CC170217906670
2064D5CUHAH60AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler F5MA5*60L*DCarrier4.5 tons55,500 Btu/h · Ducted1.8090%9.015.09.550,500CEE 25CEE 26ES CC566218477311
2065D5CUHAH60AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FEVB0060**+NAVA56001CKCarrier4.5 tons53,500 Btu/h · Ducted1.8690%9.014.59.551,500CEE 25CEE 26XcelES CC104217969657
2066D5CURAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier1.5 tons17,700 Btu/h · Ducted2.8375%7.816.010.013,300CEE 25CEE 26Xcel2,297217906671
2067D5CURAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,200 Btu/h · Ducted2.1061%9.017.010.511,800CEE 25CEE 262,955218609651
2068D5CURAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2 tons23,800 Btu/h · Ducted2.8879%8.516.09.819,500CEE 25CEE 26XcelES CC2,839217906673
2069D5CURAH24AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**ALCarrier2 tons24,800 Btu/h · Ducted2.1482%9.516.010.019,600CEE 25CEE 26XcelES CC2,166218498234
2070D5CURAH30AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier2 tons26,600 Btu/h · Ducted2.2166%7.515.29.818,800CEE 25CEE 26Xcel2,958217906674
2071D5CURAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5S30**ALCarrier2.5 tons30,400 Btu/h · Ducted2.0057%8.014.59.018,700None2,288218609531
2072D5CURAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier3 tons33,200 Btu/h · Ducted2.5472%8.114.59.025,400CEE 25CEE 26XcelES CC2,799217906675
2073D5CURAH36AAK+KSAIC0701230TEMPSTAR · Crossover heat pumpwith ducted air handler FHMA5*48L*CCarrier3.5 tons39,500 Btu/h · Ducted2.3668%8.515.29.824,400None3,134218593804
2074D5CURAH48AAKHEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0DCarrier4 tons47,500 Btu/h · Ducted1.8681%8.015.59.537,600CEE 25CEE 26XcelES CC650216772706
2075D5CURAH48AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X61M24A and furnace *80VSL0902120BCarrier4 tons48,000 Btu/h · Ducted2.0078%8.015.08.538,000ES CC712218477572

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,335 models; narrow the filters for the rest.