- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
12,335 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2051D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 2 tons23,800 Btu/h · Ducted | 2.88 | 79% | 8.5 | 16.0 | 9.8 | 19,500 | CEE 25CEE 26XcelES CC | 5,132 | 217906665 |
| 2052D5CUHAH24AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*B | Carrier | 2 tons24,200 Btu/h · Ducted | 2.06 | 83% | 9.0 | 16.0 | 11.0 | 19,000 | CEE 25CEE 26XcelES CC | 4,433 | 218486193 |
| 2053D5CUHAH24AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*B | Carrier | 2 tons24,200 Btu/h · Ducted | 2.06 | 83% | 9.0 | 16.0 | 11.0 | 19,000 | CEE 25CEE 26XcelES CC | 4,391 | 217635077 |
| 2054D5CUHAH30AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 2.5 tons28,000 Btu/h · Ducted | 2.48 | 80% | 7.8 | 15.2 | 9.8 | 23,800 | CEE 25CEE 26XcelES CC | 1,064 | 217906667 |
| 2055D5CUHAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16A | Carrier | 2.5 tons31,200 Btu/h · Ducted | 2.00 | 89% | 9.0 | 15.5 | 10.0 | 32,200 | CEE 25CEE 26XcelES CC | 4,115 | 218490362 |
| 2056D5CUHAH30AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16A | Carrier | 2.5 tons31,200 Btu/h · Ducted | 2.00 | 89% | 9.0 | 15.5 | 10.0 | 32,200 | CEE 25CEE 26XcelES CC | 4,261 | 217396826 |
| 2057D5CUHAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 3 tons35,000 Btu/h · Ducted | 2.14 | 74% | 8.0 | 15.2 | 10.0 | 27,000 | CEE 25CEE 26XcelES CC | 204 | 217906668 |
| 2058D5CUHAH36AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Carrier | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | 10.0 | 31,600 | CEE 25CEE 26XcelES CC | 3,937 | 218495042 |
| 2059D5CUHAH36AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Carrier | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | 10.0 | 31,600 | CEE 25CEE 26XcelES CC | 4,146 | 217486562 |
| 2060D5CUHAH48AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDR | Carrier | 4 tons45,000 Btu/h · Ducted | 2.43 | 75% | 8.0 | 15.2 | 9.8 | 33,800 | CEE 25CEE 26XcelES CC | 224 | 217906669 |
| 2061D5CUHAH48AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler F5MA5*60L*D | Carrier | 4 tons47,500 Btu/h · Ducted | 1.80 | 93% | 8.5 | 14.3 | 9.0 | 45,000 | ES CC | 873 | 218477319 |
| 2062D5CUHAH48AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FTMA5B60L0D | Carrier | 4 tons47,500 Btu/h · Ducted | 1.76 | 90% | 8.5 | 15.2 | 8.5 | 44,000 | None | 32 | 217414362 |
| 2063D5CUHAH60AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDR | Carrier | 4 tons45,000 Btu/h · Ducted | 2.12 | 62% | 7.5 | 15.2 | 9.8 | 35,800 | CEE 25CEE 26XcelES CC | 170 | 217906670 |
| 2064D5CUHAH60AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler F5MA5*60L*D | Carrier | 4.5 tons55,500 Btu/h · Ducted | 1.80 | 90% | 9.0 | 15.0 | 9.5 | 50,500 | CEE 25CEE 26ES CC | 566 | 218477311 |
| 2065D5CUHAH60AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FEVB0060**+NAVA56001CK | Carrier | 4.5 tons53,500 Btu/h · Ducted | 1.86 | 90% | 9.0 | 14.5 | 9.5 | 51,500 | CEE 25CEE 26XcelES CC | 104 | 217969657 |
| 2066D5CURAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 1.5 tons17,700 Btu/h · Ducted | 2.83 | 75% | 7.8 | 16.0 | 10.0 | 13,300 | CEE 25CEE 26Xcel | 2,297 | 217906671 |
| 2067D5CURAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,200 Btu/h · Ducted | 2.10 | 61% | 9.0 | 17.0 | 10.5 | 11,800 | CEE 25CEE 26 | 2,955 | 218609651 |
| 2068D5CURAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 2 tons23,800 Btu/h · Ducted | 2.88 | 79% | 8.5 | 16.0 | 9.8 | 19,500 | CEE 25CEE 26XcelES CC | 2,839 | 217906673 |
| 2069D5CURAH24AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 2 tons24,800 Btu/h · Ducted | 2.14 | 82% | 9.5 | 16.0 | 10.0 | 19,600 | CEE 25CEE 26XcelES CC | 2,166 | 218498234 |
| 2070D5CURAH30AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 2 tons26,600 Btu/h · Ducted | 2.21 | 66% | 7.5 | 15.2 | 9.8 | 18,800 | CEE 25CEE 26Xcel | 2,958 | 217906674 |
| 2071D5CURAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5S30**AL | Carrier | 2.5 tons30,400 Btu/h · Ducted | 2.00 | 57% | 8.0 | 14.5 | 9.0 | 18,700 | None | 2,288 | 218609531 |
| 2072D5CURAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 3 tons33,200 Btu/h · Ducted | 2.54 | 72% | 8.1 | 14.5 | 9.0 | 25,400 | CEE 25CEE 26XcelES CC | 2,799 | 217906675 |
| 2073D5CURAH36AAK+KSAIC0701230TEMPSTAR · Crossover heat pumpwith ducted air handler FHMA5*48L*C | Carrier | 3.5 tons39,500 Btu/h · Ducted | 2.36 | 68% | 8.5 | 15.2 | 9.8 | 24,400 | None | 3,134 | 218593804 |
| 2074D5CURAH48AAKHEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0D | Carrier | 4 tons47,500 Btu/h · Ducted | 1.86 | 81% | 8.0 | 15.5 | 9.5 | 37,600 | CEE 25CEE 26XcelES CC | 650 | 216772706 |
| 2075D5CURAH48AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X61M24A and furnace *80VSL0902120B | Carrier | 4 tons48,000 Btu/h · Ducted | 2.00 | 78% | 8.0 | 15.0 | 8.5 | 38,000 | ES CC | 712 | 218477572 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,335 models; narrow the filters for the rest.