- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
2,834 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2201SP14AY60AC2NSUREwith ducted air handler SH2CY6021STANA | Rheem | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216011629 |
| 2202SP14AY60AD2NSUREwith ducted air handler SH2CY6021STANA | Rheem | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216011632 |
| 2203SP14AY60AJ2NSUREwith ducted air handler AE*L+DM60B4J+TDR | Rheem | 4.5 tons51,500 Btu/h · Ducted | 2.49 | 61% | 7.5 | 14.3 | 8.9 | 33,200 | None | 71 | 218338284 |
| 2204SP15AY42AC2NSUREwith ducted air handler SH2CY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 2 | 216011667 |
| 2205SP15AY42AD2NSUREwith ducted air handler SH2CY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 2 | 216011668 |
| 2206SP15AY42AJ2NSUREwith ducted air handler 98-888+TXV+RDS+TDR+E30B5D | Rheem | 3.5 tons39,000 Btu/h · Ducted | 2.20 | 51% | 7.8 | 15.2 | 11.7 | 19,800 | CEE 25ES CC | 73 | 217008943 |
| 2207SP15AY48AC2NSUREwith ducted air handler SH2CY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 2 | 216011669 |
| 2208SP15AY48AD2NSUREwith ducted air handler SH2CY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 2 | 216011670 |
| 2209SP15AY48AJ2NSUREwith ducted air handler 98-888+TXV+RDS+TDR+E30B5D | Rheem | 4 tons45,000 Btu/h · Ducted | 2.30 | 54% | 7.8 | 15.2 | 11.7 | 23,800 | CEE 25CEE 26ES CC | 76 | 217008942 |
| 2210SP15AY60AJ2NSUREwith ducted air handler 98-8812+TXV+RDS+TDR+E30B6D | Rheem | 4.5 tons52,000 Btu/h · Ducted | 2.12 | 52% | 7.8 | 15.2 | 11.7 | 27,400 | None | 61 | 217008941 |
| 2211SP17AY48AJVCSURE · VANTIXwith indoor coil TCFY4821STANM and furnace S972V0705A21UPS | Rheem | 3.5 tons44,500 Btu/h · Ducted | 2.10 | 75% | 9.5 | 16.0 | 10.0 | 33,400 | CEE 25CEE 26XcelES CC | 112 | 218719349 |
| 2212SP19AY48AJVCSURE · VANTIXwith indoor coil TCFY4821SEAAM and furnace S972V0705A21UPS | Rheem | 4 tons45,500 Btu/h · Ducted | 2.20 | 76% | 8.5 | 19.0 | 12.0 | 34,800 | CEE 25CEE 26Xcel | 17 | 218728695 |
| 2213SP19AY60AJVCSURE · VANTIXwith indoor coil TCFY6021SEAAM and furnace S972V0855A21UPS | Rheem | 4.5 tons53,500 Btu/h · Ducted | 2.10 | 84% | 8.1 | 17.0 | 10.0 | 45,000 | CEE 25CEE 26Xcel | 14 | 218728709 |
| 2214UP19AY48AJVCRUUD · ULTRA SERIESwith indoor coil RCFY4821SEAAM and furnace R972V0705A21UPS | Rheem | 4 tons45,500 Btu/h · Ducted | 2.20 | 76% | 8.5 | 19.0 | 12.0 | 34,800 | CEE 25CEE 26Xcel | 20 | 218728689 |
| 2215UP19AY60AJVCRUUD · ULTRA SERIESwith indoor coil RCFY6021SEAAM and furnace R972V0855A21UPS | Rheem | 4.5 tons53,500 Btu/h · Ducted | 2.10 | 84% | 8.1 | 17.0 | 10.0 | 45,000 | CEE 25CEE 26Xcel | 18 | 218728705 |
| 2216WP14AY42AC2NRHEEMwith ducted air handler RH2TY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216011615 |
| 2217WP14AY42AD2NRHEEMwith ducted air handler RH2TY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216011617 |
| 2218WP14AY48AC2NRHEEM · VERSUSwith ducted air handler RH2TY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551697 |
| 2219WP14AY48AD2NRHEEM · VERSUSwith ducted air handler RH2TY4821STANN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551704 |
| 2220WP14AY48AJ2NWEATHERKINGwith indoor coil D(A,C,E)48B4J+TDR and furnace W801W1005A21DZ | Rheem | 3.5 tons43,500 Btu/h · Ducted | 2.50 | 61% | 7.8 | 15.2 | 10.5 | 27,400 | None | 489 | 217559376 |
| 2221WP14AY60AC2NRHEEM · VERSUSwith ducted air handler RH2TY6021STANA | Rheem | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551699 |
| 2222WP14AY60AD2NRHEEM · VERSUSwith ducted air handler RH2TY6021STANA | Rheem | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 4 | 216551706 |
| 2223WP14AY60AJ2NWEATHERKINGwith indoor coil D(A,C,E)60B4J+TDR and furnace W801W1005A21UHN | Rheem | 4.5 tons51,500 Btu/h · Ducted | 2.60 | 58% | 7.8 | 15.2 | 11.2 | 32,000 | None | 343 | 217228066 |
| 2224WP15AY42AC2NWEATHERKINGwith ducted air handler WH2TY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 5 | 216011659 |
| 2225WP15AY42AD2NWEATHERKINGwith ducted air handler WH2TY4821STANN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 5 | 216011660 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,834 models; narrow the filters for the rest.