- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
13,619 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2301D5CURAH24AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 2 tons24,800 Btu/h · Ducted | 2.14 | 82% | 9.5 | 16.0 | 10.0 | 19,600 | CEE 25CEE 26XcelES CC | 2,378 | 218498234 |
| 2302D5CURAH30AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 2 tons26,600 Btu/h · Ducted | 2.21 | 66% | 7.5 | 15.2 | 9.8 | 18,800 | CEE 25CEE 26Xcel | 2,962 | 217906674 |
| 2303D5CURAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5S30**AL | Carrier | 2.5 tons30,400 Btu/h · Ducted | 2.00 | 57% | 8.0 | 14.5 | 9.0 | 18,700 | None | 2,368 | 218609531 |
| 2304D5CURAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 3 tons33,200 Btu/h · Ducted | 2.54 | 72% | 8.1 | 14.5 | 9.0 | 25,400 | CEE 25CEE 26XcelES CC | 2,804 | 217906675 |
| 2305D5CURAH36AAK+KSAIC0701230TEMPSTAR · Crossover heat pumpwith ducted air handler FHMA5*48L*C | Carrier | 3.5 tons39,500 Btu/h · Ducted | 2.36 | 68% | 8.5 | 15.2 | 9.8 | 24,400 | None | 3,288 | 218593804 |
| 2306D5CURAH48AAKHEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0D | Carrier | 4 tons47,500 Btu/h · Ducted | 1.86 | 81% | 8.0 | 15.5 | 9.5 | 37,600 | CEE 25CEE 26XcelES CC | 650 | 216772706 |
| 2307D5CURAH48AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X61M24A and furnace *80VSL0902120B | Carrier | 4 tons48,000 Btu/h · Ducted | 2.00 | 78% | 8.0 | 15.0 | 8.5 | 38,000 | ES CC | 738 | 218477572 |
| 2308D5CURAH60AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDR | Carrier | 4 tons48,000 Btu/h · Ducted | 2.41 | 68% | 7.5 | 14.3 | 8.2 | 32,800 | ES CC | 99 | 217906677 |
| 2309D5CURAH60AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0D | Carrier | 4.5 tons52,000 Btu/h · Ducted | 1.86 | 64% | 7.5 | 14.5 | 9.0 | 38,500 | None | 26 | 218475433 |
| 2310D5CVRAH09AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAJ | Carrier | 1 ton9,000 Btu/h · Non-ducted | 1.83 | 61% | 9.0 | 18.0 | 10.1 | 6,000 | CEE 25 | 18 | 215324153 |
| 2311D5CVRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAK | Carrier | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 70% | 9.7 | 19.0 | 10.9 | 7,000 | CEE 25CEE 26XcelES CC | 18 | 215324155 |
| 2312D5CVRAH12AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH12XAJ | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.21 | 58% | 9.2 | 19.0 | 8.8 | 7,000 | None | 18 | 215324154 |
| 2313D5CVRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH12XAK | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.21 | 58% | 8.8 | 18.0 | 8.8 | 7,000 | None | 18 | 215324156 |
| 2314D5CVRAH18AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH18XAK | Carrier | 1.5 tons17,000 Btu/h · Non-ducted | 2.10 | 59% | 8.7 | 18.3 | 9.9 | 10,600 | None | 18 | 215324157 |
| 2315D5CVRAH24AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH24XAK | Carrier | 2 tons24,000 Btu/h · Non-ducted | 2.01 | 71% | 8.5 | 17.0 | 9.0 | 17,100 | XcelES CC | 18 | 215324158 |
| 2316GH5SAN518**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)29J | Carrier | 1.5 tons16,900 Btu/h · Ducted | 2.52 | 55% | 7.5 | 15.2 | 12.0 | 9,800 | None | 2,107 | 217229864 |
| 2317GH5SAN519**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**1917AM and furnace 82*TB48070V17 | Carrier | 1.5 tons19,200 Btu/h · Ducted | 2.00 | 43% | 8.0 | 15.5 | 13.0 | 8,400 | None | 1,691 | 217683721 |
| 2318GH5SAN524**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)34J | Carrier | 2 tons21,400 Btu/h · Ducted | 2.70 | 65% | 7.5 | 15.2 | 12.0 | 14,700 | CEE 25CEE 26 | 4,243 | 217229867 |
| 2319GH5SAN530**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)38J | Carrier | 2.5 tons27,000 Btu/h · Ducted | 2.66 | 57% | 7.5 | 15.2 | 12.0 | 16,500 | None | 2,447 | 217229870 |
| 2320GH5SAN531**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**3721AM and furnace 83*CB36040C17 | Carrier | 2.5 tons29,200 Btu/h · Ducted | 2.06 | 46% | 8.0 | 15.5 | 12.0 | 13,900 | CEE 25 | 1,730 | 217680505 |
| 2321GH5SAN536**AA*CARRIERwith ducted air handler C/SEHX-37-**-EP-1C81+CF037SEUB+TXV+TDR | Carrier | 3 tons34,000 Btu/h · Ducted | 2.76 | 53% | 7.8 | 15.2 | 12.2 | 17,200 | CEE 25 | 4,022 | 216064758 |
| 2322GH5SAN542**AA*CARRIERwith ducted air handler L(E,G)M48FJ | Carrier | 3.5 tons42,000 Btu/h · Ducted | 2.65 | 60% | 7.8 | 14.8 | 12.0 | 23,400 | None | 1,764 | 217195004 |
| 2323GH5SAN548**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+CM59A4J+TDR | Carrier | 3.5 tons44,000 Btu/h · Ducted | 2.70 | 61% | 7.5 | 14.8 | 11.7 | 28,400 | None | 1,492 | 215828001 |
| 2324GH5SAN560**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+DM60B4J+TDR | Carrier | 4.5 tons53,500 Btu/h · Ducted | 2.60 | 64% | 7.5 | 14.3 | 11.7 | 34,800 | None | 35 | 215828002 |
| 2325GH8TAN524**AA*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 58SU*B040M17**12 | Carrier | 2 tons23,800 Btu/h · Ducted | 2.24 | 45% | 8.5 | 18.0 | 13.0 | 11,100 | CEE 25 | 2,987 | 215647845 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 13,619 models; narrow the filters for the rest.