- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
13,619 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2426PH5SAN524**AA*PAYNE HEATING AND COOLINGwith indoor coil D(A,C,E)36A3J+TDR and furnace PG80MS(A,L)A60090C | Carrier | 2 tons21,200 Btu/h · Ducted | 2.69 | 72% | 7.5 | 15.2 | 11.2 | 15,300 | CEE 25CEE 26Xcel | 5,939 | 218853166 |
| 2427PH5SAN524**AB*WEATHERMAKERwith indoor coil D(A,C,E)37A3J+TDR and furnace PG80MS(A,L)A60090C | Carrier | 2 tons21,600 Btu/h · Ducted | 2.69 | 71% | 7.5 | 15.2 | 11.7 | 15,000 | CEE 25CEE 26Xcel | 792 | 218863611 |
| 2428PH5SAN530**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)35J | Carrier | 2 tons26,800 Btu/h · Ducted | 2.62 | 58% | 7.5 | 15.2 | 11.7 | 16,600 | None | 2,615 | 217006635 |
| 2429PH5SAN530**AB*WEATHERMAKERwith indoor coil D(A,C,E)37A3J+TDR and furnace PG80MS(A,L)A42090B | Carrier | 2 tons25,200 Btu/h · Ducted | 2.55 | 63% | 7.5 | 14.3 | 11.2 | 17,000 | None | 303 | 218863719 |
| 2430PH5SAN531**AA*PAYNE HEATING AND COOLINGwith indoor coil D(A,C,E)37A3J+TDR and furnace PG80MSUA60080C | Carrier | 2 tons26,400 Btu/h · Ducted | 2.52 | 53% | 7.8 | 15.2 | 12.0 | 15,800 | CEE 25 | 1,540 | 218863763 |
| 2431PH5SAN531**AB*WEATHERMAKERwith indoor coil D(A,C,E)37A3J+TDR and furnace PG80MSUA60080C | Carrier | 2 tons26,400 Btu/h · Ducted | 2.52 | 53% | 7.8 | 15.2 | 12.0 | 15,800 | CEE 25 | 548 | 218863877 |
| 2432PH5SAN536**AA*WEATHERMAKERwith indoor coil D(A,C,E)36A3J+TDR and furnace PG95MSUA60080C | Carrier | 2.5 tons30,400 Btu/h · Ducted | 2.62 | 70% | 7.5 | 14.3 | 11.7 | 22,400 | CEE 25 | 3,890 | 218853490 |
| 2433PH5SAN536**AB*WEATHERMAKERwith indoor coil D(A,C,E)37A3J+TDR and furnace PG95MSUA60080C | Carrier | 2.5 tons30,600 Btu/h · Ducted | 2.62 | 69% | 7.5 | 14.3 | 11.7 | 22,200 | CEE 25 | 632 | 218864037 |
| 2434PH5SAN542**AA*PAYNE HEATING AND COOLINGwith indoor coil D(A,C,E)60A3J+TDR and furnace PG80MS(A,L)A60090C | Carrier | 3.5 tons39,000 Btu/h · Ducted | 2.64 | 62% | 7.5 | 14.3 | 11.2 | 24,800 | None | 1,823 | 218853286 |
| 2435PH5SAN542**AB*WEATHERMAKERwith indoor coil D(A,C,E)61A3J+TDR and furnace PG80MSUA48060B | Carrier | 3.5 tons39,500 Btu/h · Ducted | 2.60 | 60% | 7.5 | 14.5 | 12.0 | 23,400 | None | 173 | 218864107 |
| 2436PH5SAN548**AA*PAYNE HEATING AND COOLINGwith ducted air handler AE*L+DM59A4J+TDR | Carrier | 3.5 tons44,000 Btu/h · Ducted | 2.70 | 61% | 7.5 | 14.8 | 11.7 | 28,400 | None | 1,440 | 215877093 |
| 2437PH5SAN548**AB*WEATHERMAKERwith indoor coil D(A,C,E)61A3J+TDR and furnace PG80MS(A,L)A60110D | Carrier | 3.5 tons44,000 Btu/h · Ducted | 2.56 | 60% | 7.5 | 14.3 | 11.2 | 28,600 | None | 114 | 218864127 |
| 2438PH5SAN560**AA*PAYNE HEATING AND COOLINGwith ducted air handler AE*L+DM60B4J+TDR | Carrier | 4.5 tons53,500 Btu/h · Ducted | 2.60 | 64% | 7.5 | 14.3 | 11.7 | 34,800 | None | 44 | 215946316 |
| 2439PH5SAN560**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler PF5TNBD60L | Carrier | 5 tons57,000 Btu/h · Ducted | 2.18 | 52% | 7.8 | 15.2 | 12.5 | 28,600 | None | 5 | 218754049 |
| 2440PH5SAP536**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith ducted air handler FMA5X36**AL | Carrier | 3 tons35,000 Btu/h · Ducted | 2.20 | 48% | 7.8 | 15.5 | 12.5 | 17,100 | None | 265 | 217033512 |
| 2441PH5SAP536**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler FMA5X36**AL | Carrier | 3 tons35,000 Btu/h · Ducted | 2.20 | 48% | 7.8 | 15.5 | 12.5 | 17,100 | None | 90 | 218754058 |
| 2442PH5SAP548**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith ducted air handler FT5ANBD60L | Carrier | 4 tons47,500 Btu/h · Ducted | 2.25 | 49% | 7.8 | 15.5 | 12.0 | 23,600 | None | 39 | 217033770 |
| 2443PH5SAP548**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler PF5TNBD60L | Carrier | 4 tons47,500 Btu/h · Ducted | 2.25 | 49% | 7.8 | 15.5 | 12.0 | 23,600 | None | 10 | 218754061 |
| 2444PH5SAP560**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith ducted air handler FJ5AN*D60L | Carrier | 5 tons57,500 Btu/h · Ducted | 2.10 | 52% | 7.5 | 14.5 | 12.0 | 28,600 | None | 12 | 217028395 |
| 2445PH5SAP560**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler PF5MN*D60L | Carrier | 5 tons57,500 Btu/h · Ducted | 2.10 | 52% | 7.5 | 14.5 | 12.0 | 28,600 | None | 3 | 218753797 |
| 2446PH5ZNB024000AA*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 2 tons24,000 Btu/h · Ducted | 1.56 | 35% | 6.7 | 13.4 | 11.1 | 8,000 | None | 3 | 216411327 |
| 2447PH5ZNB024000AB*WEATHERMAKER | Carrier | 2 tons24,000 Btu/h · Ducted | 1.56 | 35% | 6.7 | 13.4 | 11.1 | 8,000 | None | 1 | 218752611 |
| 2448PH5ZNB030000AA*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 2.5 tons28,600 Btu/h · Ducted | 1.75 | 39% | 6.7 | 13.4 | 11.1 | 11,100 | None | 3 | 216411328 |
| 2449PH5ZNB030000AB*WEATHERMAKER | Carrier | 2.5 tons28,600 Btu/h · Ducted | 1.75 | 39% | 6.7 | 13.4 | 11.1 | 11,100 | None | 1 | 218752612 |
| 2450PH5ZNB036000AA*BRYANT HEATING AND COOLING SYSTEMS | Carrier | 3 tons35,200 Btu/h · Ducted | 1.60 | 39% | 6.7 | 13.4 | 11.1 | 12,700 | None | 3 | 216411329 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 13,619 models; narrow the filters for the rest.