- Insights
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Compare certified heat pump ratings by size
Official test ratings for 12,478 central and mini-split heat pumps sold with today’s refrigerants, explained in plain words. Models are only compared with others of the same size and type.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
- Which models hold up best in the cold, in my size?Top cold-climate picks of one size and type, and why each one is there.Find out
- What are the ratings of a model?Look up a model number or AHRI number and see its ratings and the standards it meets.Find out
- Does a model meet a rebate standard?About 6 in 10 models meet CEE Tier 1, the level many utility rebates ask for.Find out
- How does a brand rate?Every brand’s models scored against others of the same size and type.Find out
Three numbers worth knowing
57%
of models meet CEE 2025 Tier 1, the efficiency level many utility rebates use.
7,144 of 12,478 models.
72%
of its 47°F heating output is what the typical heat pump still puts out at 5°F in the test.
The best on this one rating keep all of it, or more.
2.6%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
About 1 in 40 models (327).
Middle value (median) of the 4,554 models with cold-weather test results. Each model is measured against its own 47°F output, so sizes are not mixed. Source: NEEP cold-climate heat pump list.
Want the full temperature curves and every model’s distribution? Switch to Advanced
Top cold-climate picks, ducted 3.5–4.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
1,258 of 2,587 models in this size class qualify. 945 keep less than 70% of their heat at 5°F and 379 have no 5°F heat output rating, so they cannot show it.
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
- 1RD18AY48AJVCwith indoor coil D(A,C,E)60B4J+TDR and furnace R801V0754A17DZRheem3.5 tons · 39,000 Btu/h · DuctedKeeps 125% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 125% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.80 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 25TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRPTrane3.5 tons · 41,500 Btu/h · DuctedKeeps 108% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 108% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.81 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.5 (HSPF2)
- Great
- 3BOVA-60MTB-M19Ewith ducted air handler AE*L+DM60B4Z+TXV+TDRBosch4 tons · 49,000 Btu/h · DuctedKeeps 120% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 120% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.47 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.5 (HSPF2)
- Great
- 4SL22KLV-060-230A**with indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60CLennox4.5 tons · 52,500 Btu/h · DuctedKeeps 115% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 115% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 3.09 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
- 5KUMXA481ALG4 tons · 48,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.33 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
Top 10 cold-climate picks, ducted, 3.5–4.5 tons
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What good looks like: ducted, 3.5–4.5 tons
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 71%+
- Great
- 84%+
- Top 10%
- 98%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.10+
- Top 10%
- 2.36+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 8.1+
- Great
- 9.0+
- Top 10%
- 10.4+
What size is my system?
Tons and Btu
A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.
Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Size classes used here
- Up to 1.5 tonsunder 21,000 Btu/h
- 2 tons21,000–26,999 Btu/h
- 2.5–3 tons27,000–38,999 Btu/h
- 3.5–4.5 tons39,000–56,999 Btu/h
- 5 tons and up57,000 Btu/h and up
Ducted or ductless
A ducted (central) heat pump moves air through a home’s ducts. A ductless mini-split puts a small unit on the wall of each room. Mini-splits usually test higher (typical cooling rating 21.0 vs 16.0), partly because the test for ducted units includes pushing air through ducts. That is why they are never ranked together here.
Next steps
- Top cold-climate picks by sizeThe models of your size class that hold up best in the cold, and why.
- Check a model numberIts ratings, where it sits in its size class, and the standards it meets.
- Check rebate standardsThe efficiency levels rebate programs use, in plain words.
- Look up a QMIDThe federal 25C tax credit needs the manufacturer’s Qualified Manufacturer ID.
Contractor, utility or analyst? The advanced view has every distribution, peer percentile, standards flow and data table behind these answers.
Open the advanced view