Skip to content

Compare certified heat pump ratings by size

Official test ratings for 12,478 central and mini-split heat pumps sold with today’s refrigerants, explained in plain words. Models are only compared with others of the same size and type.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Three numbers worth knowing

  • 57%

    of models meet CEE 2025 Tier 1, the efficiency level many utility rebates use.

    7,144 of 12,478 models.

    See which ones

  • 72%

    of its 47°F heating output is what the typical heat pump still puts out at 5°F in the test.

    The best on this one rating keep all of it, or more.

    See them by size

  • 2.6%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    About 1 in 40 models (327).

    See the cold-climate tier

Heating output as it gets colderIn the 5°F test, the typical ducted heat pump puts out 71% of its 47°F heating output, and the typical ductless one 67%.

Middle value (median) of the 4,554 models with cold-weather test results. Each model is measured against its own 47°F output, so sizes are not mixed. Source: NEEP cold-climate heat pump list.

Want the full temperature curves and every model’s distribution? Switch to Advanced

Top cold-climate picks, ductless 5 tons and up

Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.

32 of 86 models in this size class qualify. 54 keep less than 70% of their heat at 5°F.

  1. 1AVW-60F3DAH2Hisense5 tons · 60,000 Btu/h · DuctlessKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    11.0 (HSPF2)
    Top 10%
    98.2score / 100
  2. 2CHV6-RS60URBMHHCooper&Hunter (sold as Cooper & Hunter)5 tons · 60,000 Btu/h · DuctlessKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    11.0 (HSPF2)
    Top 10%
    98.2score / 100
  3. 3KUMXB601ALG5 tons · 58,000 Btu/h · DuctlessKeeps 82% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.33 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    9.8 (HSPF2)
    Good
    84.7score / 100
  4. 4AM060FCMDCG1Samsung5 tons · 60,000 Btu/h · DuctlessKeeps 85% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.11 (COP at 5°F)
    Good
    Seasonal efficiency
    11.0 (HSPF2)
    Top 10%
    84.1score / 100
  5. 5VPD060H6M-5PLennox5 tons · 60,000 Btu/h · DuctlessKeeps 85% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.11 (COP at 5°F)
    Good
    Seasonal efficiency
    11.0 (HSPF2)
    Top 10%
    84.1score / 100

Top 10 cold-climate picks, ductless, 5 tons and up

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ductless, 5 tons and up

The words on the picks above: good is better than half of this size class, great is the top quarter, top is the top 10%. Each scale comes from the class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    65%+
    Great
    71%+
    Top 10%
    83%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    2.05+
    Great
    2.20+
    Top 10%
    2.20+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    9.5+
    Great
    10.1+
    Top 10%
    10.5+

What size is my system?

Tons and Btu

A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.

Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Size classes used here

  • Up to 1.5 tonsunder 21,000 Btu/h
  • 2 tons21,000–26,999 Btu/h
  • 2.5–3 tons27,000–38,999 Btu/h
  • 3.5–4.5 tons39,000–56,999 Btu/h
  • 5 tons and up57,000 Btu/h and up

Ducted or ductless

A ducted (central) heat pump moves air through a home’s ducts. A ductless mini-split puts a small unit on the wall of each room. Mini-splits usually test higher (typical cooling rating 21.0 vs 16.0), partly because the test for ducted units includes pushing air through ducts. That is why they are never ranked together here.

Next steps

Contractor, utility or analyst? The advanced view has every distribution, peer percentile, standards flow and data table behind these answers.

Open the advanced view