Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
1HVAC vs TGM heat pumps
Measured against models of the same size and duct type, 1HVAC scores higher on 6 of the 6 ratings. 1HVAC has 70 outdoor models, TGM has 77 outdoor models. 1HVAC and TGM have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- 1HVAC
- TGM
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | 1HVAC | TGM |
|---|---|---|
| Efficiency index | 61% (higher)median — | 45% (higher)median — |
| COP at 5°F | 57% (higher)median 2.00 | 48% (higher)median 1.91 |
| Capacity retention at 5°F | 59% (higher)median 78% | 42% (higher)median 71% |
| HSPF2 | 71% (higher)median 10.0 | 41% (higher)median 8.6 |
| SEER2 | 64% (higher)median 19.8 | 45% (higher)median 19.0 |
| EER2 | 55% (higher)median 12.0 | 42% (higher)median 11.2 |
| Heating capacity at 5°F | 62% (higher)median 21,000 Btu/h | 47% (higher)median 14,100 Btu/h |
| Outdoor models | 70 | 77 |
| AHRI certifications | 166 | 152 |
Share of models meeting each standard
| Standard | 1HVAC | TGM |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 87.1%61 models | 58.4%45 models |
| CEE 2026 Tier 1 (Split ASHP) | 85.7%60 models | 57.1%44 models |
| CEE Advanced Tier (Split ASHP) | 4.3%3 models | 1.3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 74.3%52 models | 54.5%42 models |
| DOE Cold Climate Heat Pump Challenge | 4.3%3 models | 1.3%1 models |
| ENERGY STAR Cold Climate | 77.1%54 models | 20.8%16 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- 1HVAC
- TGM
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | 1HVAC | TGM |
|---|---|---|
| Ducted, up to 1.5 tons | 8 · index 75% | 5 · index 62% |
| Ducted, 2 tons | 8 · index 65% | 8 · index 67% |
| Ducted, 2.5–3 tons | 12 · index 65% | 10 · index 50% |
| Ducted, 3.5–4.5 tons | 17 · index 65% | 11 · index 61% |
| Ducted, 5 tons and up | 1 · index 63% | 2 · index 69% |
| Non-ducted, up to 1.5 tons | 22 · index 59% | 32 · index 34% |
| Non-ducted, 2 tons | 6 · index 53% | 9 · index 43% |
| Non-ducted, 2.5–3 tons | 9 · index 48% | 8 · index 40% |
| Non-ducted, 3.5–4.5 tons | 6 · index 53% | 5 · index 43% |
| Non-ducted, 5 tons and up | 1 · index 59% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | 1HVACCold-climate score, best model | TGMCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.7(50 is the typical model of its size class) (higher)ACIQ-18-HPDwith ducted air handler ACIQ-18W-WMB7 of 8 models qualify · AHRI 216980821 | 69.8(50 is the typical model of its size class)MRS5VHT18ASwith ducted air handler MFC5VHT18S3 of 5 models qualify · AHRI 217274613 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC8 of 8 models qualify · AHRI 216032281 | 77.1(50 is the typical model of its size class)MRS5VHT24ASwith ducted air handler MFC5VHT24S6 of 8 models qualify · AHRI 217274615 |
| Ducted, 2.5–3 tons | 83.2(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Cwith ducted air handler ACIQ-36CD-HH-MC11 of 12 models qualify · AHRI 216032282 | 63.6(50 is the typical model of its size class)MTVC2OCN036Awith ducted air handler MTA20C036A3 of 10 models qualify · AHRI 218044247 |
| Ducted, 3.5–4.5 tons | 85.1(50 is the typical model of its size class) (higher)ACIQ-60-HP32with ducted air handler ACIQ-60-AH3217 of 17 models qualify · AHRI 215387237 | 72.2(50 is the typical model of its size class)OTV18HN048Awith ducted air handler OTA18C006AAlso listed as OTV18HN060A7 of 11 models qualify · AHRI 217747072 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 64.1(50 is the typical model of its size class)MRB560HWD1 of 2 models qualify · AHRI 217194656 |
| Non-ducted, up to 1.5 tons | 96.7(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD14 of 22 models qualify · AHRI 216032267 | 79.2(50 is the typical model of its size class)ARHHBT18ASwith ductless indoor unit AWHHBT18S22 of 32 models qualify · AHRI 218620807 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24CC-HH-MC4 of 6 models qualify · AHRI 216032275 | 77.9(50 is the typical model of its size class)MRS5VHT24ASwith ductless indoor unit MUV5HT24S6 of 9 models qualify · AHRI 216706039 |
| Non-ducted, 2.5–3 tons | 89.4(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Cwith ductless indoor unit ACIQ-36FM-HH-MD6 of 9 models qualify · AHRI 216032289 | 77.2(50 is the typical model of its size class)GMRSHT36AS46 of 8 models qualify · AHRI 217284813 |
| Non-ducted, 3.5–4.5 tons | 73.4(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M6C6 of 6 models qualify · AHRI 216032306 | 66.5(50 is the typical model of its size class)GMRSHT42AS53 of 5 models qualify · AHRI 217284814 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | 1HVACAll-around score, best model | TGMAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.5(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Cwith ducted air handler ACIQ-09CD-HH-MC8 of 8 models have all five ratings · AHRI 216032278 | 78.4(50 is the typical model of its size class)MRS5VHT18ASwith ducted air handler MFC5VHT18S3 of 5 models have all five ratings · AHRI 217274613 |
| Ducted, 2 tons | 78.4(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC8 of 8 models have all five ratings · AHRI 216032281 | 79.6(50 is the typical model of its size class) (higher)CTV520HN036Awith ducted air handler CTA520C024A6 of 8 models have all five ratings · AHRI 217138121 |
| Ducted, 2.5–3 tons | 83.6(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M5C12 of 12 models have all five ratings · AHRI 216032302 | 72.8(50 is the typical model of its size class)MTVC2OCN036Awith ducted air handler MTA20C036A6 of 10 models have all five ratings · AHRI 218044247 |
| Ducted, 3.5–4.5 tons | 85.1(50 is the typical model of its size class) (higher)ES-48Z-M6C17 of 17 models have all five ratings · AHRI 216032320 | 72.6(50 is the typical model of its size class)OTV18HN048Awith ducted air handler OTA18C006AAlso listed as OTV18HN060A8 of 11 models have all five ratings · AHRI 217747072 |
| Ducted, 5 tons and up | 62.5(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032323 | 70.5(50 is the typical model of its size class) (higher)MRB560HWD2 of 2 models have all five ratings · AHRI 217194656 |
| Non-ducted, up to 1.5 tons | 96.2(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD22 of 22 models have all five ratings · AHRI 216032267 | 82.9(50 is the typical model of its size class)ARHHBT18ASwith ductless indoor unit AWHHBT18S32 of 32 models have all five ratings · AHRI 218620807 |
| Non-ducted, 2 tons | 76.4(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24W-HH-MD6 of 6 models have all five ratings · AHRI 216032271 | 86.5(50 is the typical model of its size class) (higher)ARHHBT24ASwith ductless indoor unit AWHHBT24S9 of 9 models have all five ratings · AHRI 218620808 |
| Non-ducted, 2.5–3 tons | 78.3(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M5C9 of 9 models have all five ratings · AHRI 216032301 | 64.5(50 is the typical model of its size class)GMRSHT36AS47 of 8 models have all five ratings · AHRI 217284813 |
| Non-ducted, 3.5–4.5 tons | 75.6(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M6C6 of 6 models have all five ratings · AHRI 216032304 | 67.7(50 is the typical model of its size class)GMRSHT42AS54 of 5 models have all five ratings · AHRI 217284814 |
| Non-ducted, 5 tons and up | 58.6(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032322 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | 1HVAC | TGM |
|---|---|---|
| COP at 5°F | beats 98% · 2.44EZ-18ZPL-HP230BNon-ducted, up to 1.5 tons | beats 98% · 2.50ARHCPT18ASNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 98% · 126%ACIQ-09ZPL-HP230CNon-ducted, up to 1.5 tons | beats 88% · 70%MRB560HWDDucted, 5 tons and up |
| HSPF2 | beats 99% · 14.8ACIQ-06ZPL-HP230CNon-ducted, up to 1.5 tons | beats 94% · 9.7MR5SVHT60ASDucted, 5 tons and up |
| SEER2 | beats 97% · 25.0ES-27Z-M4CNon-ducted, 2.5–3 tons | beats 97% · 22.0TMRHT18AS2Ducted, up to 1.5 tons |
| EER2 | beats 99% · 18.0ACIQ-06ZPL-HP230CNon-ducted, up to 1.5 tons | beats 96% · 14.0ARHHBT24ASNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 98% · 19,600 Btu/hACIQ-18-HPDDucted, up to 1.5 tons | beats 86% · 15,000 Btu/hARHHBT18ASNon-ducted, up to 1.5 tons |