ABCOOLAIR vs Innovair heat pumps
Measured against models of the same size and duct type, Innovair scores higher on 5 of the 6 ratings. ABCOOLAIR has 6 outdoor models, Innovair has 126 outdoor models. ABCOOLAIR has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ABCOOLAIR
- Innovair
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ABCOOLAIR | Innovair |
|---|---|---|
| Efficiency index | 58%median — | 58%median — · 8th ranked |
| COP at 5°F | 52%median 2.00 | 58%median 2.00 · 12th ranked |
| Capacity retention at 5°F | 29%median 50% | 60%median 78% · 7th ranked |
| HSPF2 | 55%median 8.2 | 61%median 9.5 · 8th ranked |
| SEER2 | 51%median 15.6 | 60%median 20.0 · 9th ranked |
| EER2 | 91% (higher)median 12.5 | 51% (higher)median 11.7 · 16th ranked |
| Heating capacity at 5°F | 31%median 26,300 Btu/h | 60%median 19,000 Btu/h · 9th ranked |
| Outdoor models | 6 | 126 |
| AHRI certifications | 11 | 484 |
Share of models meeting each standard
| Standard | ABCOOLAIR | Innovair |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50%3 models | 82.5%104 models |
| CEE 2026 Tier 1 (Split ASHP) | 50%3 models | 80.2%101 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 1.6%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 78.6%99 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 1.6%2 models |
| ENERGY STAR Cold Climate | 0%0 models | 69%87 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ABCOOLAIR
- Innovair
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ABCOOLAIR | Innovair |
|---|---|---|
| Ducted, 3.5–4.5 tons | 4 · index 56% | 23 · index 64% |
| Ducted, 5 tons and up | 2 · index 63% | 4 · index 63% |
| Ducted, up to 1.5 tons | None | 19 · index 70% |
| Ducted, 2 tons | None | 11 · index 59% |
| Ducted, 2.5–3 tons | None | 26 · index 62% |
| Non-ducted, up to 1.5 tons | None | 48 · index 53% |
| Non-ducted, 2 tons | None | 9 · index 52% |
| Non-ducted, 2.5–3 tons | None | 20 · index 54% |
| Non-ducted, 3.5–4.5 tons | None | 12 · index 52% |
| Non-ducted, 5 tons and up | None | 2 · index 59% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ABCOOLAIRCold-climate score, best model | InnovairCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 86.7(50 is the typical model of its size class)SHV18H2BAwith ducted air handler SWV18BDA16 of 18 models qualify · AHRI 216027612 |
| Ducted, 2 tons | No models in this size class | 85.7(50 is the typical model of its size class)MOS24H2BH0Awith ducted air handler MDH24H2MHWA10 of 12 models qualify · AHRI 215725473 |
| Ducted, 2.5–3 tons | No models in this size class | 83.2(50 is the typical model of its size class)MOS36H2BH0Awith ducted air handler MDH36H2MHWA22 of 26 models qualify · AHRI 215735335 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 4 models qualify) | 82.7(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B20 of 23 models qualify · AHRI 215725526 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 58.3(50 is the typical model of its size class)PXV60H2A1 of 4 models qualify · AHRI 217753792 |
| Non-ducted, up to 1.5 tons | No models in this size class | 96.7(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB38 of 48 models qualify · AHRI 215725442 |
| Non-ducted, 2 tons | No models in this size class | 89.4(50 is the typical model of its size class)MOS24H2BH0Awith ductless indoor unit MCS24H2BHRA9 of 9 models qualify · AHRI 217230001 |
| Non-ducted, 2.5–3 tons | No models in this size class | 89.4(50 is the typical model of its size class)MOS36H2BH0Awith ductless indoor unit MFC36H2BHRA16 of 20 models qualify · AHRI 217230015 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 73.4(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B11 of 12 models qualify · AHRI 215725527 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | ABCOOLAIRAll-around score, best model | InnovairAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 86.7(50 is the typical model of its size class)MOS09H2BH0Awith ducted air handler MDL09H2MHWA17 of 18 models have all five ratings · AHRI 215725467 |
| Ducted, 2 tons | No models in this size class | 79.6(50 is the typical model of its size class)GOV36H2BAwith ducted air handler GAV24B2A10 of 11 models have all five ratings · AHRI 215318726 |
| Ducted, 2.5–3 tons | No models in this size class | 83.6(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B25 of 27 models have all five ratings · AHRI 215725523 |
| Ducted, 3.5–4.5 tons | 63.9(50 is the typical model of its size class)GLZT7CA4810A*with ducted air handler AMVT60DP1300A4 of 4 models have all five ratings · AHRI 216369289 | 85.1(50 is the typical model of its size class) (higher)MOM48H2BM6AAlso listed as MOM48H2BM6B20 of 23 models have all five ratings · AHRI 215725499 |
| Ducted, 5 tons and up | 63.0(50 is the typical model of its size class)GLZS5BA6010A*with ducted air handler AMST60DU1300A2 of 2 models have all five ratings · AHRI 216369253 | 67.5(50 is the typical model of its size class) (higher)MOS60H2BM0Awith ducted air handler MDH60H2MHWA4 of 4 models have all five ratings · AHRI 215725466 |
| Non-ducted, up to 1.5 tons | No models in this size class | 96.2(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB48 of 48 models have all five ratings · AHRI 215725442 |
| Non-ducted, 2 tons | No models in this size class | 86.8(50 is the typical model of its size class)MOS24H2BM0Awith ductless indoor unit MHW24H2BHRB9 of 9 models have all five ratings · AHRI 215725441 |
| Non-ducted, 2.5–3 tons | No models in this size class | 78.3(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B20 of 20 models have all five ratings · AHRI 215725522 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 75.6(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B12 of 12 models have all five ratings · AHRI 215725525 |
| Non-ducted, 5 tons and up | No models in this size class | 58.6(50 is the typical model of its size class)MOM60H2BM6AAlso listed as MOM60H2BM6B2 of 2 models have all five ratings · AHRI 215835696 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ABCOOLAIR | Innovair |
|---|---|---|
| COP at 5°F | beats 54% · 2.00GLZS4BA6010A*Ducted, 3.5–4.5 tons | beats 100% · 2.80MOM27H2XE3ANon-ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 50% · 53%GLZT7CA6010A*Ducted, 5 tons and up | beats 100% · 133%QOS09H2BH0ADucted, up to 1.5 tons |
| HSPF2 | beats 66% · 8.2GLZS5BA6010A*Ducted, 5 tons and up | beats 99% · 14.8MOS06H2BH0ANon-ducted, up to 1.5 tons |
| SEER2 | beats 67% · 17.2GLZT7CA4810A*Ducted, 3.5–4.5 tons | beats 99% · 22.0POM27H2BM3ADucted, 2.5–3 tons |
| EER2 | beats 93% · 12.5GLZS4BA6010A*Ducted, 3.5–4.5 tons | beats 99% · 18.0MOS06H2BH0ANon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 54% · 31,000 Btu/hGLZT7CA6010A*Ducted, 5 tons and up | beats 98% · 19,600 Btu/hSHV18H2BADucted, up to 1.5 tons |