Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Airevantage vs Sinclair heat pumps
Measured against models of the same size and duct type, Airevantage and Sinclair split the 6 ratings 3–3. Airevantage has 17 outdoor models, Sinclair has 17 outdoor models. Airevantage and Sinclair have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Airevantage
- Sinclair
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Airevantage | Sinclair |
|---|---|---|
| Efficiency index | 22%median — | 26%median — |
| COP at 5°F | 19%median 1.75 | 45%median 1.84 |
| Capacity retention at 5°F | 19% (higher)median 48% | 14% (higher)median 41% |
| HSPF2 | 26% (higher)median 7.5 | 14% (higher)median 6.7 |
| SEER2 | 21% (higher)median 14.3 | 13% (higher)median 13.4 |
| EER2 | 25%median 10.6 | 44%median 11.2 |
| Heating capacity at 5°F | 21%median 16,300 Btu/h | 22%median 17,100 Btu/h |
| Outdoor models | 17 | 17 |
| AHRI certifications | 40 | 239 |
Share of models meeting each standard
| Standard | Airevantage | Sinclair |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 17.6%3 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Airevantage
- Sinclair
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Airevantage | Sinclair |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 20% | 2 · index 32% |
| Ducted, 2 tons | 3 · index 18% | 3 · index 19% |
| Ducted, 2.5–3 tons | 5 · index 21% | 5 · index 26% |
| Ducted, 3.5–4.5 tons | 8 · index 25% | 7 · index 28% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AirevantageCold-climate score, best model | SinclairCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | 34.9(50 is the typical model of its size class)A5H7V24AKAAwith ducted air handler ACVE245CB1 of 3 models qualify · AHRI 218729467 | None on this board (0 of 3 models qualify) |
| Ducted, 2.5–3 tons | None on this board (0 of 5 models qualify) | None on this board (0 of 5 models qualify) |
| Ducted, 3.5–4.5 tons | 44.1(50 is the typical model of its size class)A5H7V48AKAAwith ducted air handler ACVE605CC2 of 8 models qualify · AHRI 218736484 | None on this board (0 of 7 models qualify) |
All-around best
| Size and duct type | AirevantageAll-around score, best model | SinclairAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 20.3(50 is the typical model of its size class)USH4BE5M1SP18Kwith indoor coil C75B(A,H)MX24C-A and furnace FG7S(*)-(*)A(*)1 of 1 models have all five ratings · AHRI 217169857 | 37.2(50 is the typical model of its size class) (higher)SHP0182301152SNCXFC454Bwith ducted air handler AHU036175MESNCXF454B1 of 1 models have all five ratings · AHRI 217127865 |
| Ducted, 2 tons | 27.6(50 is the typical model of its size class)A5H7V24AKAAwith ducted air handler ACVE245CB3 of 3 models have all five ratings · AHRI 218729467 | 40.5(50 is the typical model of its size class) (higher)SHP0242301152SNCXFC454Bwith ducted air handler AHU030175WESNCXF454B3 of 3 models have all five ratings · AHRI 217127855 |
| Ducted, 2.5–3 tons | 40.1(50 is the typical model of its size class)A5H7V36AKAAwith ducted air handler ACVE365CC5 of 5 models have all five ratings · AHRI 218729468 | 52.8(50 is the typical model of its size class) (higher)SHP0362301152SNCXFC454Bwith ducted air handler AHU060021MESNCXF454B5 of 5 models have all five ratings · AHRI 217127870 |
| Ducted, 3.5–4.5 tons | 34.6(50 is the typical model of its size class)A5H7V60AKAAwith ducted air handler ACVE605CC8 of 8 models have all five ratings · AHRI 218729469 | 57.1(50 is the typical model of its size class) (higher)SHP0422301152SNCXFC454Bwith ducted air handler AHU060021MESNCXF454B8 of 8 models have all five ratings · AHRI 217127871 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Airevantage | Sinclair |
|---|---|---|
| COP at 5°F | beats 87% · 2.26A5H7V36AKAADucted, 2.5–3 tons | beats 95% · 2.55SHP0482301152SNCXFC454BDucted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 42% · 70%A5H7V60AKAADucted, 3.5–4.5 tons | beats 33% · 59%SHP0482301152SNCXFC454BDucted, 3.5–4.5 tons |
| HSPF2 | beats 57% · 8.6A5H7V36AKAADucted, 2.5–3 tons | beats 38% · 7.8SHP0422301152SNCXFC454BDucted, 3.5–4.5 tons |
| SEER2 | beats 50% · 16.0A5H7V60AKAADucted, 3.5–4.5 tons | beats 35% · 15.2SHP0422301152SNCXFC454BDucted, 3.5–4.5 tons |
| EER2 | beats 40% · 11.0USH4BE5M1SP42KDucted, 3.5–4.5 tons | beats 83% · 12.0SHP0422301152SNCXFC454BDucted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 53% · 37,800 Btu/hA5H7V60AKAADucted, 3.5–4.5 tons | beats 71% · 12,700 Btu/hSHP0242301152SNCXFC454BDucted, up to 1.5 tons |