Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Bluefin vs The Heat Pump heat pumps
Measured against models of the same size and duct type, The Heat Pump scores higher on 5 of the 6 ratings. Bluefin has 3 outdoor models, The Heat Pump has 3 outdoor models. Bluefin and The Heat Pump have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Bluefin
- The Heat Pump
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Bluefin | The Heat Pump |
|---|---|---|
| Efficiency index | 53%median — | 72%median — |
| COP at 5°F | 45%median 1.99 | 61%median 2.00 |
| Capacity retention at 5°F | 26%median 70% | 92%median 100% |
| HSPF2 | 41%median 9.4 | 69%median 10.0 |
| SEER2 | 73% (higher)median 22.3 | 66% (higher)median 18.0 |
| EER2 | 62%median 12.2 | 76%median 12.5 |
| Heating capacity at 5°F | 34%median 19,000 Btu/h | 93%median 24,000 Btu/h |
| Outdoor models | 3 | 3 |
| AHRI certifications | 5 | 9 |
Share of models meeting each standard
| Standard | Bluefin | The Heat Pump |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%3 models | 100%3 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%3 models | 100%3 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 33.3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 66.7%2 models | 100%3 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 33.3%1 models |
| ENERGY STAR Cold Climate | 66.7%2 models | 100%3 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Bluefin
- The Heat Pump
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Bluefin | The Heat Pump |
|---|---|---|
| Ducted, 2 tons | 1 · index 65% | 1 · index 72% |
| Ducted, up to 1.5 tons | None | 1 · index 66% |
| Ducted, 3.5–4.5 tons | None | 1 · index 79% |
| Non-ducted, up to 1.5 tons | 1 · index 49% | None |
| Non-ducted, 2 tons | 1 · index 57% | None |
| Non-ducted, 2.5–3 tons | 1 · index 39% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BluefinCold-climate score, best model | The Heat PumpCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 62.5(50 is the typical model of its size class)THP-GUD18W2/NHE-D(U)with ducted air handler THP-GUD18AH2/E-D(U)1 of 1 models qualify · AHRI 218338354 |
| Ducted, 2 tons | 48.6(50 is the typical model of its size class)BFMS27MZPL-02O1 of 1 models qualify · AHRI 216719248 | No models in this size class |
| Ducted, 2.5–3 tons | No models in this size class | 76.9(50 is the typical model of its size class)THP-GUD36W2/NHE-D(U)with ducted air handler THP-GUD36AH2/G-D(U)1 of 1 models qualify · AHRI 218338358 |
| Ducted, 3.5–4.5 tons | No models in this size class | 85.1(50 is the typical model of its size class)THP-GUD60W2/NHE-D(U)with ducted air handler THP-GUD60AH2/G-D(U)1 of 1 models qualify · AHRI 218338362 |
| Non-ducted, up to 1.5 tons | 39.4(50 is the typical model of its size class)BFMS09BA-02Owith ductless indoor unit BFMS09BA-02I1 of 1 models qualify · AHRI 216719246 | No models in this size class |
| Non-ducted, 2 tons | 41.1(50 is the typical model of its size class)BFMS27MZPL-02O1 of 1 models qualify · AHRI 216719247 | No models in this size class |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | BluefinAll-around score, best model | The Heat PumpAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 65.8(50 is the typical model of its size class)THP-GUD18W2/NHE-D(U)with ducted air handler THP-GUD18AH2/E-D(U)1 of 1 models have all five ratings · AHRI 218338354 |
| Ducted, 2 tons | 64.5(50 is the typical model of its size class)BFMS27MZPL-02O1 of 1 models have all five ratings · AHRI 216719248 | 72.4(50 is the typical model of its size class) (higher)THP-GUD36W2/NHE-D(U)with ducted air handler THP-GUD24AH2/G-D(U)1 of 1 models have all five ratings · AHRI 218338357 |
| Ducted, 3.5–4.5 tons | No models in this size class | 83.1(50 is the typical model of its size class)THP-GUD60W2/NHE-D(U)with ducted air handler THP-GUD48AH2/G-D(U)1 of 1 models have all five ratings · AHRI 218338361 |
| Non-ducted, up to 1.5 tons | 49.2(50 is the typical model of its size class)BFMS09BA-02Owith ductless indoor unit BFMS09BA-02I1 of 1 models have all five ratings · AHRI 216719246 | No models in this size class |
| Non-ducted, 2 tons | 56.7(50 is the typical model of its size class)BFMS27MZPL-02O1 of 1 models have all five ratings · AHRI 216719247 | No models in this size class |
| Non-ducted, 2.5–3 tons | 39.4(50 is the typical model of its size class)BFMS30BA-02Owith ductless indoor unit BFMS30BA-02I1 of 1 models have all five ratings · AHRI 216719244 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Bluefin | The Heat Pump |
|---|---|---|
| COP at 5°F | beats 56% · 1.99BFMS09BA-02ONon-ducted, up to 1.5 tons | beats 69% · 2.10THP-GUD60W2/NHE-D(U)Ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 34% · 71%BFMS27MZPL-02ODucted, 2 tons | beats 94% · 100%THP-GUD60W2/NHE-D(U)Ducted, 3.5–4.5 tons |
| HSPF2 | beats 54% · 9.0BFMS27MZPL-02ODucted, 2 tons | beats 90% · 10.5THP-GUD60W2/NHE-D(U)Ducted, 3.5–4.5 tons |
| SEER2 | beats 94% · 21.0BFMS27MZPL-02ODucted, 2 tons | beats 85% · 19.0THP-GUD60W2/NHE-D(U)Ducted, 3.5–4.5 tons |
| EER2 | beats 62% · 12.6BFMS09BA-02ONon-ducted, up to 1.5 tons | beats 83% · 12.0THP-GUD60W2/NHE-D(U)Ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 56% · 19,000 Btu/hBFMS27MZPL-02ONon-ducted, 2 tons | beats 98% · 54,000 Btu/hTHP-GUD60W2/NHE-D(U)Ducted, 3.5–4.5 tons |