Century vs Liberty Heating & Air Conditioning heat pumps
Measured against models of the same size and duct type, Liberty Heating & Air Conditioning scores higher on 4 of the 6 ratings. Century has 59 outdoor models, Liberty Heating & Air Conditioning has 6 outdoor models. Century and Liberty Heating & Air Conditioning have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Century
- Liberty Heating & Air Conditioning
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Century | Liberty Heating & Air Conditioning |
|---|---|---|
| Efficiency index | 50%median — | 58%median — |
| COP at 5°F | 50%median 1.98 | 52%median 2.00 |
| Capacity retention at 5°F | 49% (higher)median 63% | 29% (higher)median 50% |
| HSPF2 | 52%median 8.1 | 55%median 8.2 |
| SEER2 | 45%median 15.2 | 51%median 15.6 |
| EER2 | 53%median 11.4 | 91%median 12.5 |
| Heating capacity at 5°F | 49% (higher)median 19,000 Btu/h | 31% (higher)median 26,300 Btu/h |
| Outdoor models | 59 | 6 |
| AHRI certifications | 1,147 | 15 |
Share of models meeting each standard
| Standard | Century | Liberty Heating & Air Conditioning |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 44.1%26 models | 50%3 models |
| CEE 2026 Tier 1 (Split ASHP) | 44.1%26 models | 50%3 models |
| CEE Advanced Tier (Split ASHP) | 3.4%2 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 40.7%24 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 3.4%2 models | 0%0 models |
| ENERGY STAR Cold Climate | 32.2%19 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Century
- Liberty Heating & Air Conditioning
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Century | Liberty Heating & Air Conditioning |
|---|---|---|
| Ducted, up to 1.5 tons | 8 · index 72% | None |
| Ducted, 2 tons | 13 · index 41% | None |
| Ducted, 2.5–3 tons | 14 · index 42% | None |
| Ducted, 3.5–4.5 tons | 21 · index 39% | 4 · index 56% |
| Ducted, 5 tons and up | None | 2 · index 63% |
| Non-ducted, up to 1.5 tons | 6 · index 77% | None |
| Non-ducted, 2 tons | 1 · index 76% | None |
| Non-ducted, 2.5–3 tons | 3 · index 67% | None |
| Non-ducted, 3.5–4.5 tons | 2 · index 67% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CenturyCold-climate score, best model | Liberty Heating & Air ConditioningCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.6(50 is the typical model of its size class)A-VXP18SA-1with ducted air handler WXP18SA6 of 8 models qualify · AHRI 217482412 | No models in this size class |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-17 of 14 models qualify · AHRI 217482470 | No models in this size class |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)A-VHP365A-14 of 13 models qualify · AHRI 218425166 | No models in this size class |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)A-VHP486A-18 of 21 models qualify · AHRI 218425169 | None on this board (0 of 4 models qualify) |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 96.7(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models qualify · AHRI 218425153 | No models in this size class |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24CA-11 of 1 models qualify · AHRI 217482468 | No models in this size class |
| Non-ducted, 2.5–3 tons | 78.0(50 is the typical model of its size class)A-VHP365A-13 of 3 models qualify · AHRI 218425167 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 73.4(50 is the typical model of its size class)A-VHP486A-12 of 2 models qualify · AHRI 218425170 | No models in this size class |
All-around best
| Size and duct type | CenturyAll-around score, best model | Liberty Heating & Air ConditioningAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.5(50 is the typical model of its size class)A-VHP09SA-1with ducted air handler B-VHP09DA-18 of 8 models have all five ratings · AHRI 217482458 | No models in this size class |
| Ducted, 2 tons | 78.4(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-112 of 12 models have all five ratings · AHRI 217482470 | No models in this size class |
| Ducted, 2.5–3 tons | 83.6(50 is the typical model of its size class)A-VHP365A-113 of 13 models have all five ratings · AHRI 218425166 | No models in this size class |
| Ducted, 3.5–4.5 tons | 83.9(50 is the typical model of its size class) (higher)A-VHP486A-122 of 22 models have all five ratings · AHRI 218425169 | 63.9(50 is the typical model of its size class)GLZT7CA4810A*with ducted air handler AMVT60DP1300A4 of 4 models have all five ratings · AHRI 216369314 |
| Ducted, 5 tons and up | 66.7(50 is the typical model of its size class) (higher)HSA1460S1-**Awith ducted air handler HMA60VX1*-1 of 1 models have all five ratings · AHRI 216370485 | 63.0(50 is the typical model of its size class)GLZS5BA6010A*with ducted air handler AMST60DU1300A2 of 2 models have all five ratings · AHRI 216369278 |
| Non-ducted, up to 1.5 tons | 96.2(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models have all five ratings · AHRI 218425153 | No models in this size class |
| Non-ducted, 2 tons | 76.4(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24SA-11 of 1 models have all five ratings · AHRI 218425157 | No models in this size class |
| Non-ducted, 2.5–3 tons | 78.3(50 is the typical model of its size class)A-VHP365A-13 of 3 models have all five ratings · AHRI 218425165 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 75.6(50 is the typical model of its size class)A-VHP486A-12 of 2 models have all five ratings · AHRI 218425168 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Century | Liberty Heating & Air Conditioning |
|---|---|---|
| COP at 5°F | beats 98% · 2.75SHP1448S1ADucted, 3.5–4.5 tons | beats 54% · 2.00GLZS4BA6010A*Ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 98% · 126%A-VHP09SA-1Non-ducted, up to 1.5 tons | beats 50% · 53%GLZT7CA6010A*Ducted, 5 tons and up |
| HSPF2 | beats 99% · 14.8A-VHP06SA-1Non-ducted, up to 1.5 tons | beats 66% · 8.2GLZS5BA6010A*Ducted, 5 tons and up |
| SEER2 | beats 100% · 27.0A-ZHP15SA-1Ducted, up to 1.5 tons | beats 67% · 17.2GLZT7CA4810A*Ducted, 3.5–4.5 tons |
| EER2 | beats 99% · 18.0A-VHP06SA-1Non-ducted, up to 1.5 tons | beats 93% · 12.5GLZS4BA6010A*Ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 98% · 19,600 Btu/hA-VXP18SA-1Ducted, up to 1.5 tons | beats 54% · 31,000 Btu/hGLZT7CA6010A*Ducted, 5 tons and up |