Skip to content

Century vs Cooper&Hunter heat pumps

Measured against models of the same size and duct type, Cooper&Hunter scores higher on 6 of the 6 ratings. Century has 59 outdoor models, Cooper&Hunter has 63 outdoor models. Century has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Century and Cooper&Hunter on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Cooper&Hunter scores higher on 6 of the 6 ratings.
  • Century
  • Cooper&Hunter
  • Other ranked manufacturers
CenturyCooper&H…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCenturyCooper&Hunter
Efficiency index50%median —64%median — · 1st ranked
COP at 5°F50%median 1.9865%median 2.10 · 3rd ranked
Capacity retention at 5°F49%median 63%62%median 80% · 5th ranked
HSPF252%median 8.173%median 10.2 · 1st ranked
SEER245%median 15.265%median 21.0 · 2nd ranked
EER253%median 11.458%median 12.0 · 9th ranked
Heating capacity at 5°F49%median 19,000 Btu/h65%median 24,000 Btu/h · 5th ranked
Outdoor models5963
AHRI certifications1,147260

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCenturyCooper&Hunter
CEE 2025 Tier 1 (Split ASHP)44.1%26 models85.7%54 models
CEE 2026 Tier 1 (Split ASHP)44.1%26 models84.1%53 models
CEE Advanced Tier (Split ASHP)3.4%2 models7.9%5 models
Xcel Energy Colorado cold-climate ASHP (2025)40.7%24 models73%46 models
DOE Cold Climate Heat Pump Challenge3.4%2 models7.9%5 models
ENERGY STAR Cold Climate32.2%19 models71.4%45 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • Century
  • Cooper&Hunter
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCenturyCooper&Hunter
Ducted, up to 1.5 tons8 · index 72%12 · index 74%
Ducted, 2 tons13 · index 41%6 · index 62%
Ducted, 2.5–3 tons14 · index 42%15 · index 67%
Ducted, 3.5–4.5 tons21 · index 39%14 · index 67%
Ducted, 5 tons and upNone3 · index 66%
Non-ducted, up to 1.5 tons6 · index 77%20 · index 65%
Non-ducted, 2 tons1 · index 76%4 · index 60%
Non-ducted, 2.5–3 tons3 · index 67%13 · index 62%
Non-ducted, 3.5–4.5 tons2 · index 67%11 · index 50%
Non-ducted, 5 tons and upNone2 · index 71%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCenturyCold-climate score, best modelCooper&HunterCold-climate score, best model
Ducted, up to 1.5 tons86.6(50 is the typical model of its size class)A-VXP18SA-1with ducted air handler WXP18SA6 of 8 models qualify · AHRI 21748241293.5(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 215864212
Ducted, 2 tons85.7(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-17 of 14 models qualify · AHRI 21748247085.7(50 is the typical model of its size class)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 215864219
Ducted, 2.5–3 tons82.5(50 is the typical model of its size class)A-VHP365A-14 of 13 models qualify · AHRI 21842516684.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 217026552
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class)A-VHP486A-18 of 21 models qualify · AHRI 21842516982.7(50 is the typical model of its size class)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 215864279
Ducted, 5 tons and upNo models in this size class88.2(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models qualify · AHRI 21842515396.7(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 215864172
Non-ducted, 2 tons89.4(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24CA-11 of 1 models qualify · AHRI 21748246889.4(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 215864191
Non-ducted, 2.5–3 tons78.0(50 is the typical model of its size class)A-VHP365A-13 of 3 models qualify · AHRI 21842516792.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 217026553
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class)A-VHP486A-12 of 2 models qualify · AHRI 21842517094.6(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 217026556
Non-ducted, 5 tons and upNo models in this size class98.2(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCenturyAll-around score, best modelCooper&HunterAll-around score, best model
Ducted, up to 1.5 tons86.5(50 is the typical model of its size class)A-VHP09SA-1with ducted air handler B-VHP09DA-18 of 8 models have all five ratings · AHRI 21748245895.0(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 215864212
Ducted, 2 tons78.4(50 is the typical model of its size class)A-VHP24SA-1with ducted air handler B-VHP24DA-112 of 12 models have all five ratings · AHRI 21748247078.8(50 is the typical model of its size class) (higher)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 215864228
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class)A-VHP365A-113 of 13 models have all five ratings · AHRI 21842516683.6(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 215864276
Ducted, 3.5–4.5 tons83.9(50 is the typical model of its size class)A-VHP486A-122 of 22 models have all five ratings · AHRI 21842516985.1(50 is the typical model of its size class) (higher)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 215864264
Ducted, 5 tons and up66.7(50 is the typical model of its size class)HSA1460S1-**Awith ducted air handler HMA60VX1*-1 of 1 models have all five ratings · AHRI 21637048570.5(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 217026558
Non-ducted, up to 1.5 tons96.2(50 is the typical model of its size class)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models have all five ratings · AHRI 21842515396.2(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 215864172
Non-ducted, 2 tons76.4(50 is the typical model of its size class)A-VHP24SA-1with ductless indoor unit B-VHP24SA-11 of 1 models have all five ratings · AHRI 21842515786.8(50 is the typical model of its size class) (higher)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 215864171
Non-ducted, 2.5–3 tons78.3(50 is the typical model of its size class)A-VHP365A-13 of 3 models have all five ratings · AHRI 21842516586.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 217026553
Non-ducted, 3.5–4.5 tons75.6(50 is the typical model of its size class)A-VHP486A-12 of 2 models have all five ratings · AHRI 21842516882.7(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 217026556
Non-ducted, 5 tons and upNo models in this size class83.5(50 is the typical model of its size class)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 217026559

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCenturyCooper&Hunter
COP at 5°Fbeats 98% · 2.75SHP1448S1ADucted, 3.5–4.5 tonsbeats 99% · 2.40CHV6-RS48URBMHHNon-ducted, 3.5–4.5 tons
Capacity retention at 5°Fbeats 98% · 126%A-VHP09SA-1Non-ducted, up to 1.5 tonsbeats 100% · 100%CHV6-RS60URBMHHDucted, 5 tons and up
HSPF2beats 99% · 14.8A-VHP06SA-1Non-ducted, up to 1.5 tonsbeats 99% · 14.8CH-RHP06F9-230VONon-ducted, up to 1.5 tons
SEER2beats 100% · 27.0A-ZHP15SA-1Ducted, up to 1.5 tonsbeats 97% · 25.0CH-R28MES-230VONon-ducted, 2.5–3 tons
EER2beats 99% · 18.0A-VHP06SA-1Non-ducted, up to 1.5 tonsbeats 99% · 18.0CH-RHP06F9-230VONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 19,600 Btu/hA-VXP18SA-1Ducted, up to 1.5 tonsbeats 100% · 63,000 Btu/hCHV6-RS60URBMHHDucted, 5 tons and up

More comparisons