Comfort Temps vs OUTES heat pumps
Measured against models of the same size and duct type, Comfort Temps and OUTES split the 6 ratings 3–3. Comfort Temps has 20 outdoor models, OUTES has 20 outdoor models. Comfort Temps and OUTES have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Comfort Temps
- OUTES
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Comfort Temps | OUTES |
|---|---|---|
| Efficiency index | 49%median — | 65%median — |
| COP at 5°F | 37%median 1.89 | 65%median 2.05 |
| Capacity retention at 5°F | 38%median 72% | 65%median 76% |
| HSPF2 | 53% (higher)median 9.5 | 38% (higher)median 7.5 |
| SEER2 | 59% (higher)median 23.0 | 37% (higher)median 14.3 |
| EER2 | 52% (higher)median 12.3 | 50% (higher)median 11.4 |
| Heating capacity at 5°F | 41%median 9,100 Btu/h | 65%median 31,000 Btu/h |
| Outdoor models | 20 | 20 |
| AHRI certifications | 20 | 49 |
Share of models meeting each standard
| Standard | Comfort Temps | OUTES |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%20 models | 30%6 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%20 models | 30%6 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 90%18 models | 30%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 60%12 models | 30%6 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Comfort Temps
- OUTES
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Comfort Temps | OUTES |
|---|---|---|
| Ducted, up to 1.5 tons | None | 2 · index — |
| Ducted, 2 tons | None | 4 · index 71% |
| Ducted, 2.5–3 tons | None | 5 · index 58% |
| Ducted, 3.5–4.5 tons | None | 9 · index 64% |
| Non-ducted, up to 1.5 tons | 16 · index 50% | None |
| Non-ducted, 2 tons | 4 · index 45% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Comfort TempsCold-climate score, best model | OUTESCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | No models in this size class | 68.7(50 is the typical model of its size class)ORT-H24DEMR3-M01/SE1802 of 4 models qualify · AHRI 218389013 |
| Ducted, 2.5–3 tons | No models in this size class | 64.7(50 is the typical model of its size class)ORT-H36DEMR3-M01/SE1801 of 5 models qualify · AHRI 218361292 |
| Ducted, 3.5–4.5 tons | No models in this size class | 72.2(50 is the typical model of its size class)OTD-H60DMR3-C01/SE180with ducted air handler OAH-C48DMR3-B02/SE1803 of 9 models qualify · AHRI 216437867 |
| Non-ducted, up to 1.5 tons | 59.5(50 is the typical model of its size class)CTP-BH122A-Owith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O15 of 16 models qualify · AHRI 216472852 | No models in this size class |
| Non-ducted, 2 tons | 37.7(50 is the typical model of its size class)CTP-BH242A-Owith ductless indoor unit CTP-BH242A-IAlso listed as CTP-BH242A-O3 of 4 models qualify · AHRI 216472854 | No models in this size class |
All-around best
| Size and duct type | Comfort TempsAll-around score, best model | OUTESAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 2 models have all five ratings) |
| Ducted, 2 tons | No models in this size class | 73.1(50 is the typical model of its size class)ORT-H24DEMR3-M01/SE1802 of 4 models have all five ratings · AHRI 218389013 |
| Ducted, 2.5–3 tons | No models in this size class | 58.3(50 is the typical model of its size class)ORT-H36DEMR3-M01/SE1801 of 5 models have all five ratings · AHRI 218361292 |
| Ducted, 3.5–4.5 tons | No models in this size class | 72.6(50 is the typical model of its size class)OTD-H60DMR3-C01/SE180with ducted air handler OAH-C48DMR3-B02/SE1803 of 9 models have all five ratings · AHRI 216437867 |
| Non-ducted, up to 1.5 tons | 67.7(50 is the typical model of its size class)CTP-BH122A-Owith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O16 of 16 models have all five ratings · AHRI 216472852 | No models in this size class |
| Non-ducted, 2 tons | 52.8(50 is the typical model of its size class)CTP-BH242A-Owith ductless indoor unit CTP-BH242A-IAlso listed as CTP-BH242A-O4 of 4 models have all five ratings · AHRI 216472854 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Comfort Temps | OUTES |
|---|---|---|
| COP at 5°F | beats 77% · 2.10CTP-BH121A-OAlso listed as CTP-BH121A-ONon-ducted, up to 1.5 tons | beats 86% · 2.30OTD-H60DMR3-C01/SE180Ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 52% · 76%CTP-BH242A-OAlso listed as CTP-BH242A-ONon-ducted, 2 tons | beats 96% · 103%ORT-H24DEMR3-M01/SE180Ducted, 2 tons |
| HSPF2 | beats 64% · 10.0CEL-BH092A-ONon-ducted, up to 1.5 tons | beats 74% · 9.2OTD-H60DMR3-C01/SE180Ducted, 3.5–4.5 tons |
| SEER2 | beats 79% · 23.0CTP-BH242A-OAlso listed as CTP-BH242A-ONon-ducted, 2 tons | beats 81% · 18.5OTD-H60DMR3-C01/SE180Ducted, 3.5–4.5 tons |
| EER2 | beats 70% · 13.0CTP-BH091A-OAlso listed as CTP-BH091A-ONon-ducted, up to 1.5 tons | beats 83% · 12.0OTD-H42SMR3-C01/SE143Ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 79% · 13,600 Btu/hCTP-BH182A-OAlso listed as CTP-BH182A-ONon-ducted, up to 1.5 tons | beats 94% · 24,600 Btu/hORT-H24DEMR3-M01/SE180Ducted, 2 tons |