Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Comfort Temps vs KeplerX heat pumps
Measured against models of the same size and duct type, Comfort Temps scores higher on 4 of the 6 ratings. Comfort Temps has 20 outdoor models, KeplerX has 20 outdoor models. Comfort Temps and KeplerX have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Comfort Temps
- KeplerX
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Comfort Temps | KeplerX |
|---|---|---|
| Efficiency index | 49% (higher)median — | 42% (higher)median — |
| COP at 5°F | 37% (higher)median 1.89 | 34% (higher)median 1.80 |
| Capacity retention at 5°F | 38%median 72% | 41%median 60% |
| HSPF2 | 53% (higher)median 9.5 | 52% (higher)median 8.5 |
| SEER2 | 59% (higher)median 23.0 | 58% (higher)median 17.4 |
| EER2 | 52% (higher)median 12.3 | 26% (higher)median 10.5 |
| Heating capacity at 5°F | 41%median 9,100 Btu/h | 46%median 23,200 Btu/h |
| Outdoor models | 20 | 20 |
| AHRI certifications | 20 | 20 |
Share of models meeting each standard
| Standard | Comfort Temps | KeplerX |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%20 models | 35%7 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%20 models | 35%7 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 90%18 models | 25%5 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 60%12 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Comfort Temps
- KeplerX
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Comfort Temps | KeplerX |
|---|---|---|
| Ducted, up to 1.5 tons | None | 2 · index 34% |
| Ducted, 2 tons | None | 4 · index 50% |
| Ducted, 2.5–3 tons | None | 6 · index 39% |
| Ducted, 3.5–4.5 tons | None | 8 · index 43% |
| Non-ducted, up to 1.5 tons | 16 · index 50% | None |
| Non-ducted, 2 tons | 4 · index 45% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Comfort TempsCold-climate score, best model | KeplerXCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | No models in this size class | 70.4(50 is the typical model of its size class)K18HVH24WD2R2 of 4 models qualify · AHRI 217894015 |
| Ducted, 2.5–3 tons | No models in this size class | 43.5(50 is the typical model of its size class)K18HVH36WD2R1 of 6 models qualify · AHRI 217894016 |
| Ducted, 3.5–4.5 tons | No models in this size class | 60.3(50 is the typical model of its size class)K18HVH48WD2R2 of 8 models qualify · AHRI 217894017 |
| Non-ducted, up to 1.5 tons | 59.5(50 is the typical model of its size class)CTP-BH122A-Owith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O15 of 16 models qualify · AHRI 216472852 | No models in this size class |
| Non-ducted, 2 tons | 37.7(50 is the typical model of its size class)CTP-BH242A-Owith ductless indoor unit CTP-BH242A-IAlso listed as CTP-BH242A-O3 of 4 models qualify · AHRI 216472854 | No models in this size class |
All-around best
| Size and duct type | Comfort TempsAll-around score, best model | KeplerXAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 38.9(50 is the typical model of its size class)K18HVH18WD2UN3with ducted air handler K18HVH18WD2HN32 of 2 models have all five ratings · AHRI 217894009 |
| Ducted, 2 tons | No models in this size class | 76.9(50 is the typical model of its size class)K20HVH24WD2VN3with ducted air handler K20HVH24WD2HN34 of 4 models have all five ratings · AHRI 218043800 |
| Ducted, 2.5–3 tons | No models in this size class | 54.1(50 is the typical model of its size class)K20HVH36WD2VN3with ducted air handler K20HVH36WD2HN36 of 6 models have all five ratings · AHRI 218043801 |
| Ducted, 3.5–4.5 tons | No models in this size class | 65.5(50 is the typical model of its size class)K18HVH48WD2R8 of 8 models have all five ratings · AHRI 217894017 |
| Non-ducted, up to 1.5 tons | 67.7(50 is the typical model of its size class)CTP-BH122A-Owith ductless indoor unit CTP-BH122A-IAlso listed as CTP-BH122A-O16 of 16 models have all five ratings · AHRI 216472852 | No models in this size class |
| Non-ducted, 2 tons | 52.8(50 is the typical model of its size class)CTP-BH242A-Owith ductless indoor unit CTP-BH242A-IAlso listed as CTP-BH242A-O4 of 4 models have all five ratings · AHRI 216472854 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Comfort Temps | KeplerX |
|---|---|---|
| COP at 5°F | beats 77% · 2.10CTP-BH121A-OAlso listed as CTP-BH121A-ONon-ducted, up to 1.5 tons | beats 90% · 2.35K20HVH48WD2VN3Ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 52% · 76%CTP-BH242A-OAlso listed as CTP-BH242A-ONon-ducted, 2 tons | beats 97% · 103%K18HVH24WD2RDucted, 2 tons |
| HSPF2 | beats 64% · 10.0CEL-BH092A-ONon-ducted, up to 1.5 tons | beats 69% · 9.0K18HVH48WD2RDucted, 3.5–4.5 tons |
| SEER2 | beats 79% · 23.0CTP-BH242A-OAlso listed as CTP-BH242A-ONon-ducted, 2 tons | beats 86% · 19.3K20HVH36WD2VN3Ducted, 2.5–3 tons |
| EER2 | beats 70% · 13.0CTP-BH091A-OAlso listed as CTP-BH091A-ONon-ducted, up to 1.5 tons | beats 81% · 12.5K20HVH24WD2VN3Ducted, 2 tons |
| Heating capacity at 5°F | beats 79% · 13,600 Btu/hCTP-BH182A-OAlso listed as CTP-BH182A-ONon-ducted, up to 1.5 tons | beats 97% · 25,800 Btu/hK18HVH24WD2RDucted, 2 tons |