Both views use the same certified data. This device remembers your choice.
Bravo vs KeplerX heat pumps
Measured against models of the same size and duct type, Bravo and KeplerX split the 6 ratings 3 to 3. Bravo has 20 outdoor models, KeplerX has 20 outdoor models. Bravo and KeplerX have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Bravo
- KeplerX
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Bravo | KeplerX |
|---|---|---|
| Efficiency index | 45% (higher)median — | 42% (higher)median — |
| COP at 5°F | 42% (higher)median 1.90 | 34% (higher)median 1.80 |
| Capacity retention at 5°F | 39%median 64% | 41%median 60% |
| HSPF2 | 54% (higher)median 9.5 | 51% (higher)median 8.5 |
| SEER2 | 52%median 17.9 | 58%median 17.4 |
| EER2 | 40% (higher)median 10.5 | 27% (higher)median 10.5 |
| Heating capacity at 5°F | 40%median 16,250 Btu/h | 46%median 23,200 Btu/h |
| Outdoor models | 20 | 20 |
| AHRI certifications | 34 | 20 |
Share of models meeting each standard
| Standard | Bravo | KeplerX |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50%10 models | 35%7 models |
| CEE 2026 Tier 1 (Split ASHP) | 50%10 models | 35%7 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 40%8 models | 25%5 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 15%3 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Bravo
- KeplerX
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Bravo | KeplerX |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index 51% | 2 · index 36% |
| Ducted, 2 tons | 2 · index 48% | 4 · index 50% |
| Ducted, 2.5 to 3 tons | 4 · index 58% | 6 · index 39% |
| Ducted, 3.5 to 4.5 tons | 3 · index 51% | 8 · index 43% |
| Non-ducted, up to 1.5 tons | 7 · index 33% | None |
| Non-ducted, 2 tons | 3 · index 40% | None |
| Non-ducted, 2.5 to 3 tons | 3 · index 42% | None |
| Non-ducted, 3.5 to 4.5 tons | 1 · index 75% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BravoCold-climate score, best model | KeplerXCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 56.5(50 is the typical model of its size class)BRV-M18-230VO1 of 2 models qualify · AHRI 217221457 | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | 59.1(50 is the typical model of its size class)BRV-M24-230VO1 of 2 models qualify · AHRI 217221458 | 70.1(50 is the typical model of its size class) (higher)K18HVH24WD2R2 of 4 models qualify · AHRI 217894015 |
| Ducted, 2.5 to 3 tons | 73.7(50 is the typical model of its size class) (higher)BRV-M30-230VO2 of 4 models qualify · AHRI 217221459 | 43.0(50 is the typical model of its size class)K18HVH36WD2R1 of 6 models qualify · AHRI 217894016 |
| Ducted, 3.5 to 4.5 tons | 77.1(50 is the typical model of its size class) (higher)BRV-M42-230VO1 of 3 models qualify · AHRI 217221461 | 60.2(50 is the typical model of its size class)K18HVH48WD2R2 of 8 models qualify · AHRI 217894017 |
| Non-ducted, up to 1.5 tons | 66.2(50 is the typical model of its size class)BRV-M18-230VO3 of 7 models qualify · AHRI 217221452 | No models in this size class |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)BRV-M24-230VO2 of 3 models qualify · AHRI 217221453 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 63.1(50 is the typical model of its size class)BRV-M30-230VO2 of 3 models qualify · AHRI 217221464 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 60.3(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models qualify · AHRI 217221466 | No models in this size class |
All-around best
| Size and duct type | BravoAll-around score, best model | KeplerXAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 62.0(50 is the typical model of its size class) (higher)BRV-M18-230VO2 of 2 models have all five ratings · AHRI 217221457 | 40.1(50 is the typical model of its size class)K18HVH18WD2UN3with ducted air handler K18HVH18WD2HN32 of 2 models have all five ratings · AHRI 217894009 |
| Ducted, 2 tons | 66.1(50 is the typical model of its size class)BRV-M24-230VO2 of 2 models have all five ratings · AHRI 217221458 | 76.9(50 is the typical model of its size class) (higher)K20HVH24WD2VN3with ducted air handler K20HVH24WD2HN34 of 4 models have all five ratings · AHRI 218043800 |
| Ducted, 2.5 to 3 tons | 80.8(50 is the typical model of its size class) (higher)BRV-M30-230VO4 of 4 models have all five ratings · AHRI 217221459 | 54.3(50 is the typical model of its size class)K20HVH36WD2VN3with ducted air handler K20HVH36WD2HN36 of 6 models have all five ratings · AHRI 218043801 |
| Ducted, 3.5 to 4.5 tons | 87.2(50 is the typical model of its size class) (higher)BRV-M42-230VO3 of 3 models have all five ratings · AHRI 217221461 | 66.1(50 is the typical model of its size class)K18HVH48WD2R8 of 8 models have all five ratings · AHRI 217894017 |
| Non-ducted, up to 1.5 tons | 63.6(50 is the typical model of its size class)BRV-P09LS-230VOwith ductless indoor unit BRV-P09CT-230VI7 of 7 models have all five ratings · AHRI 218425279 | No models in this size class |
| Non-ducted, 2 tons | 73.3(50 is the typical model of its size class)BRV-M24-230VO3 of 3 models have all five ratings · AHRI 217221453 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 67.4(50 is the typical model of its size class)BRV-M30-230VO3 of 3 models have all five ratings · AHRI 217221454 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 74.5(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models have all five ratings · AHRI 217221466 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Bravo | KeplerX |
|---|---|---|
| COP at 5°F | beats 82% · 2.05BRV-M30-230VONon-ducted, 2.5 to 3 tons | beats 90% · 2.35K20HVH48WD2VN3Ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 81% · 90%BRV-M24-230VONon-ducted, 2 tons | beats 97% · 103%K18HVH24WD2RDucted, 2 tons |
| HSPF2 | beats 87% · 10.0BRV-M42-230VODucted, 3.5 to 4.5 tons | beats 69% · 9.0K18HVH48WD2RDucted, 3.5 to 4.5 tons |
| SEER2 | beats 100% · 22.0BRV-M42-230VODucted, 3.5 to 4.5 tons | beats 86% · 19.3K20HVH36WD2VN3Ducted, 2.5 to 3 tons |
| EER2 | beats 91% · 12.3BRV-M42-230VODucted, 3.5 to 4.5 tons | beats 82% · 12.5K20HVH24WD2VN3Ducted, 2 tons |
| Heating capacity at 5°F | beats 86% · 14,500 Btu/hBRV-M18-230VONon-ducted, up to 1.5 tons | beats 97% · 25,800 Btu/hK18HVH24WD2RDucted, 2 tons |