Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
EG4 vs Upstreman heat pumps
Measured against models of the same size and duct type, EG4 scores higher on 6 of the 6 ratings. EG4 has 11 outdoor models, Upstreman has 11 outdoor models. EG4 and Upstreman have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- EG4
- Upstreman
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | EG4 | Upstreman |
|---|---|---|
| Efficiency index | 66% (higher)median — | 26% (higher)median — |
| COP at 5°F | 76% (higher)median 2.10 | 47% (higher)median 2.00 |
| Capacity retention at 5°F | 75% (higher)median 95% | 4% (higher)median 54% |
| HSPF2 | 72% (higher)median 10.0 | 9% (higher)median 8.2 |
| SEER2 | 58% (higher)median 21.5 | 30% (higher)median 18.1 |
| EER2 | 65% (higher)median 12.6 | 26% (higher)median 11.3 |
| Heating capacity at 5°F | 64% (higher)median 18,250 Btu/h | 15% (higher)median 6,500 Btu/h |
| Outdoor models | 11 | 11 |
| AHRI certifications | 11 | 11 |
Share of models meeting each standard
| Standard | EG4 | Upstreman |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 72.7%8 models | 45.5%5 models |
| CEE 2026 Tier 1 (Split ASHP) | 72.7%8 models | 45.5%5 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 72.7%8 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 72.7%8 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- EG4
- Upstreman
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | EG4 | Upstreman |
|---|---|---|
| Ducted, up to 1.5 tons | None | 2 · index 48% |
| Non-ducted, up to 1.5 tons | 6 · index 64% | 8 · index 18% |
| Non-ducted, 2 tons | 4 · index 67% | 1 · index — |
| Non-ducted, 2.5–3 tons | 1 · index 71% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EG4Cold-climate score, best model | UpstremanCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 82.4(50 is the typical model of its size class)DWLA4-ACDC1-12KR2(US)with ductless indoor unit DGLA4-ACDC1-12KR2(US)Also listed as DWLA4-12KR2(US)3 of 6 models qualify · AHRI 216772360 | None on this board (0 of 8 models qualify) |
| Non-ducted, 2 tons | 84.5(50 is the typical model of its size class)DWLC2-ACDC-24KR2(US)with ductless indoor unit DGLA3-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)4 of 4 models qualify · AHRI 216772362 | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5–3 tons | 71.7(50 is the typical model of its size class)DW4E1-ACDC-36KR2(US)1 of 1 models qualify · AHRI 217958903 | No models in this size class |
All-around best
| Size and duct type | EG4All-around score, best model | UpstremanAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 47.7(50 is the typical model of its size class)I12-230Wwith ducted air handler I12-230GAlso listed as UI12-230W2 of 2 models have all five ratings · AHRI 217175294 |
| Non-ducted, up to 1.5 tons | 70.7(50 is the typical model of its size class) (higher)DWLA4-ACDC1-12KR2(US)with ductless indoor unit DGLA4-ACDC1-12KR2(US)Also listed as DWLA4-12KR2(US)3 of 6 models have all five ratings · AHRI 216772360 | 28.7(50 is the typical model of its size class)I12-115Wwith ductless indoor unit I12-115GAlso listed as UI12-115W6 of 8 models have all five ratings · AHRI 217175293 |
| Non-ducted, 2 tons | 72.1(50 is the typical model of its size class)DWLC2-ACDC-24KR2(US)with ductless indoor unit DGLA3-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)4 of 4 models have all five ratings · AHRI 216772362 | None on this board (0 of 1 models have all five ratings) |
| Non-ducted, 2.5–3 tons | 70.6(50 is the typical model of its size class)DW4E1-ACDC-36KR2(US)1 of 1 models have all five ratings · AHRI 217958903 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | EG4 | Upstreman |
|---|---|---|
| COP at 5°F | beats 97% · 2.23DW4E1-ACDC-36KR2(US)Non-ducted, 2.5–3 tons | beats 88% · 2.22IY18-230W-1Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 116%DWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tons | beats 11% · 54%I12-230WAlso listed as UI12-230WDucted, up to 1.5 tons |
| HSPF2 | beats 87% · 11.0DWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tons | beats 25% · 8.5I12-230WAlso listed as UI12-230WDucted, up to 1.5 tons |
| SEER2 | beats 84% · 25.0DWA4-09KR2(US)Non-ducted, up to 1.5 tons | beats 82% · 20.0I12-230WAlso listed as UI12-230WDucted, up to 1.5 tons |
| EER2 | beats 87% · 14.5DWA4-09KR2(US)Non-ducted, up to 1.5 tons | beats 35% · 11.6IY18-230WNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 81% · 22,000 Btu/hDWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tons | beats 52% · 9,500 Btu/hIY18-230W-1Non-ducted, up to 1.5 tons |