Skip to content

Deye vs Upstreman heat pumps

Measured against models of the same size and duct type, Deye scores higher on 6 of the 6 ratings. Deye has 11 outdoor models, Upstreman has 11 outdoor models. Deye and Upstreman have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Deye and Upstreman on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Deye scores higher on 6 of the 6 ratings.
  • Deye
  • Upstreman
  • Other ranked manufacturers
DeyeUpstreman

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDeyeUpstreman
Efficiency index66% (higher)median —26% (higher)median —
COP at 5°F76% (higher)median 2.1047% (higher)median 2.00
Capacity retention at 5°F75% (higher)median 95%4% (higher)median 54%
HSPF272% (higher)median 10.09% (higher)median 8.2
SEER258% (higher)median 21.530% (higher)median 18.1
EER265% (higher)median 12.626% (higher)median 11.3
Heating capacity at 5°F64% (higher)median 18,250 Btu/h15% (higher)median 6,500 Btu/h
Outdoor models1111
AHRI certifications1111

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDeyeUpstreman
CEE 2025 Tier 1 (Split ASHP)72.7%8 models45.5%5 models
CEE 2026 Tier 1 (Split ASHP)72.7%8 models45.5%5 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)72.7%8 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate72.7%8 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • Deye
  • Upstreman
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDeyeUpstreman
Ducted, up to 1.5 tonsNone2 · index 48%
Non-ducted, up to 1.5 tons6 · index 64%8 · index 18%
Non-ducted, 2 tons4 · index 67%1 · index —
Non-ducted, 2.5–3 tons1 · index 71%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDeyeCold-climate score, best modelUpstremanCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons82.4(50 is the typical model of its size class)DWLA4-ACDC1-12KR2(US)with ductless indoor unit DGLA4-ACDC1-12KR2(US)Also listed as DWLA4-12KR2(US)3 of 6 models qualify · AHRI 216021341None on this board (0 of 8 models qualify)
Non-ducted, 2 tons84.5(50 is the typical model of its size class)DWLC2-ACDC-24KR2(US)with ductless indoor unit DGLA3-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)4 of 4 models qualify · AHRI 216021343None on this board (0 of 1 models qualify)
Non-ducted, 2.5–3 tons71.7(50 is the typical model of its size class)DW4E1-ACDC-36KR2(US)1 of 1 models qualify · AHRI 217617797No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDeyeAll-around score, best modelUpstremanAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class47.7(50 is the typical model of its size class)I12-230Wwith ducted air handler I12-230GAlso listed as UI12-230W2 of 2 models have all five ratings · AHRI 217175294
Non-ducted, up to 1.5 tons70.7(50 is the typical model of its size class) (higher)DWLA4-ACDC1-12KR2(US)with ductless indoor unit DGLA4-ACDC1-12KR2(US)Also listed as DWLA4-12KR2(US)3 of 6 models have all five ratings · AHRI 21602134128.7(50 is the typical model of its size class)I12-115Wwith ductless indoor unit I12-115GAlso listed as UI12-115W6 of 8 models have all five ratings · AHRI 217175293
Non-ducted, 2 tons72.1(50 is the typical model of its size class)DWLC2-ACDC-24KR2(US)with ductless indoor unit DGLA3-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)4 of 4 models have all five ratings · AHRI 216021343None on this board (0 of 1 models have all five ratings)
Non-ducted, 2.5–3 tons70.6(50 is the typical model of its size class)DW4E1-ACDC-36KR2(US)1 of 1 models have all five ratings · AHRI 217617797No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDeyeUpstreman
COP at 5°Fbeats 97% · 2.23DW4E1-ACDC-36KR2(US)Non-ducted, 2.5–3 tonsbeats 88% · 2.22IY18-230W-1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 116%DWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tonsbeats 11% · 54%I12-230WAlso listed as UI12-230WDucted, up to 1.5 tons
HSPF2beats 87% · 11.0DWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tonsbeats 25% · 8.5I12-230WAlso listed as UI12-230WDucted, up to 1.5 tons
SEER2beats 84% · 25.0DWA4-09KR2(US)Non-ducted, up to 1.5 tonsbeats 82% · 20.0I12-230WAlso listed as UI12-230WDucted, up to 1.5 tons
EER2beats 87% · 14.5DWA4-09KR2(US)Non-ducted, up to 1.5 tonsbeats 35% · 11.6IY18-230WNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 81% · 22,000 Btu/hDWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tonsbeats 52% · 9,500 Btu/hIY18-230W-1Non-ducted, up to 1.5 tons

More comparisons