- Insights
- Manufacturers
- Upstreman
Both views use the same certified data. This device remembers your choice.
Upstreman heat pump efficiency: 19 outdoor models compared
Upstreman has 19 heat pump outdoor models certified with this refrigerant group, in 19 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Upstreman makes. Upstreman has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 19
- AHRI certifications
- 19
- Efficiency index
- 30%
- Typical model vs same-size, same-type peers (19 models)
- Meet CEE 2025
- 57.9%
- 11 models
How Upstreman compares with comparable models
- Upstreman
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index19 models scored | 30% | Not ranked | — |
| COP at 5°F19 models scored | 58% | Not ranked | 2.00 |
| Capacity retention at 5°F19 models scored | 13% | Not ranked | 55% |
| HSPF219 models scored | 16% | Not ranked | 8.5 |
| SEER219 models scored | 34% | Not ranked | 20.0 |
| EER219 models scored | 27% | Not ranked | 11.0 |
| Heating capacity at 5°F19 models scored | 28% | Not ranked | 9,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 57.9% | 11 |
| CEE 2026 Tier 1 (Split ASHP) | 57.9% | 11 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 21.1% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Upstreman (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 49% | 72% | 28% | 83% |
| Non-ducted, up to 1.5 tons | 11 | 24% | 51% | 11% | 27% |
| Non-ducted, 2 tons | 3 | 32% | 86% | 10% | 30% |
| Non-ducted, 2.5 to 3 tons | 2 | 40% | 53% | 38% | 33% |
| Non-ducted, 3.5 to 4.5 tons | 1 | 27% | 37% | 14% | 29% |
Every Upstreman model in the market
- Upstreman models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Upstreman models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1I28-230ODUUpstreman | 2.5 tons28,000 Btu/h · Non-ducted | 75% | 2.00 | 9.5 | 21,000 | 20.0 | CEE 25CEE 26Xcel | 1 | 218080014 | Non-ducted, 2.5 to 3 tons | 48.6 |
| 2I36-230ODUUpstreman | 3 tons38,000 Btu/h · Non-ducted | 74% | 2.00 | 9.5 | 31,000 | 20.0 | CEE 25CEE 26Xcel | 1 | 218080015 | Non-ducted, 2.5 to 3 tons | 47.6 |
| 3I20-230ODUUpstreman | 1.5 tons20,000 Btu/h · Non-ducted | 70% | 2.00 | 9.5 | 14,000 | 23.0 | CEE 25CEE 26Xcel | 1 | 218080013 | Non-ducted, up to 1.5 tons | 46.3 |
| 4I42-230ODUUpstreman | 3.5 tons42,000 Btu/h · Non-ducted | 74% | 2.00 | 9.5 | 31,000 | 20.0 | CEE 25CEE 26Xcel | 1 | 218080016 | Non-ducted, 3.5 to 4.5 tons | 24.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1I20-230ODUUpstreman | 1.5 tons20,000 Btu/h · Non-ducted | 70% | 2.00 | 9.5 | 23.0 | 11.2 | CEE 25CEE 26Xcel | 1 | 218080013 | Non-ducted, up to 1.5 tons | 49.5 | 46.3 | 52.8 | 46.3 |
| 2I12-230Wupstremanwith ducted air handler I12-230GAlso listed as UI12-230W | 1 ton12,000 Btu/h · Ducted | 54% | 2.05 | 8.5 | 20.0 | 11.4 | CEE 25CEE 26 | 1 | 217175294 | Ducted, up to 1.5 tons | 48.9 | 36.8 | 61.0 | Not a pick |
| 3I28-230ODUUpstreman | 2.5 tons28,000 Btu/h · Non-ducted | 75% | 2.00 | 9.5 | 20.0 | 11.0 | CEE 25CEE 26Xcel | 1 | 218080014 | Non-ducted, 2.5 to 3 tons | 40.1 | 48.6 | 31.6 | 48.6 |
| 4I36-230ODUUpstreman | 3 tons38,000 Btu/h · Non-ducted | 74% | 2.00 | 9.5 | 20.0 | 11.0 | CEE 25CEE 26Xcel | 1 | 218080015 | Non-ducted, 2.5 to 3 tons | 39.6 | 47.6 | 31.6 | 47.6 |
| 5I24-230Wupstremanwith ductless indoor unit I24-230GAlso listed as UI24-230W | 2 tons24,000 Btu/h · Non-ducted | 53% | 2.20 | 8.5 | 20.0 | 10.9 | None | 1 | 218214245 | Non-ducted, 2 tons | 34.5 | 33.5 | 35.6 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | IY18-230WAlso listed as IY18-230W-1 | 2.22 | Non-ducted, up to 1.5 tons | 89% | 218258559 |
| Capacity retention at 5°F | I28-230ODU | 75% | Non-ducted, 2.5 to 3 tons | 53% | 218080014 |
| HSPF2 | I20-230ODU | 9.5 | Non-ducted, up to 1.5 tons | 47% | 218080013 |
| SEER2 | I12-230WAlso listed as UI12-230W | 20.0 | Ducted, up to 1.5 tons | 83% | 217175294 |
| EER2 | IY18-230WAlso listed as IY18-230W-1 | 11.6 | Non-ducted, up to 1.5 tons | 39% | 218258559 |
| Heating capacity at 5°F | I20-230ODU | 14,000 Btu/h | Non-ducted, up to 1.5 tons | 84% | 218080013 |
Upstreman size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | 48.9(50 is the typical model of its size class)I12-230Wwith ducted air handler I12-230GAlso listed as UI12-230W2 of 2 models have all five ratings · AHRI 217175294 |
| Non-ducted, up to 1.5 tons | 46.3(50 is the typical model of its size class)I20-230ODU1 of 11 models qualify · AHRI 218080013 | 49.5(50 is the typical model of its size class)I20-230ODU11 of 11 models have all five ratings · AHRI 218080013 |
| Non-ducted, 2 tons | None on this board (0 of 3 models qualify) | 34.5(50 is the typical model of its size class)I24-230Wwith ductless indoor unit I24-230GAlso listed as UI24-230W3 of 3 models have all five ratings · AHRI 218214245 |
| Non-ducted, 2.5 to 3 tons | 48.6(50 is the typical model of its size class)I28-230ODU2 of 2 models qualify · AHRI 218080014 | 40.1(50 is the typical model of its size class)I28-230ODU2 of 2 models have all five ratings · AHRI 218080014 |
| Non-ducted, 3.5 to 4.5 tons | 24.6(50 is the typical model of its size class)I42-230ODU1 of 1 models qualify · AHRI 218080016 | 26.8(50 is the typical model of its size class)I42-230ODU1 of 1 models have all five ratings · AHRI 218080016 |
Newest Upstreman certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| IY18-230W-1Upstremanwith ductless indoor unit IY18-230G-1 | 1.5 tons17,100 Btu/h · Non-ducted | 2.22 | 55% | 8.2 | 18.1 | CEE 25CEE 26 | 1 | 218806023 |
| IY12-230W-1Upstremanwith ductless indoor unit IY12-230G-1 | 1 ton12,000 Btu/h · Non-ducted | 1.67 | 48% | 8.2 | 18.1 | None | 1 | 218806022 |
| IY12-115W-1Upstremanwith ductless indoor unit IY12-115G-1 | 1 ton12,100 Btu/h · Non-ducted | 1.76 | 52% | 8.2 | 18.1 | None | 1 | 218806021 |
| IY12-115WUpstremanwith ductless indoor unit IY12-115G | 1 ton12,100 Btu/h · Non-ducted | 1.76 | 52% | 8.2 | 18.1 | None | 1 | 218806020 |
| IY24-230WUpstremanwith ductless indoor unit IY24-230G | 2 tons23,400 Btu/h · Non-ducted | 2.28 | 53% | 8.2 | 18.1 | CEE 25CEE 26 | 1 | 218258560 |
Compare Upstreman
Upstreman includes these brand names as listed in AHRI: upstreman. Standards are checked against published thresholds; program rules beyond ratings are not checked.