Skip to content

Deye vs Legacy Systems heat pumps

Measured against models of the same size and duct type, Deye scores higher on 5 of the 6 ratings. Deye has 11 outdoor models, Legacy Systems has 11 outdoor models. Deye and Legacy Systems have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Deye and Legacy Systems on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Deye scores higher on 5 of the 6 ratings.
  • Deye
  • Legacy Systems
  • Other ranked manufacturers
DeyeLegacy S…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDeyeLegacy Systems
Efficiency index66% (higher)median —44% (higher)median —
COP at 5°F76% (higher)median 2.1040% (higher)median 1.90
Capacity retention at 5°F75% (higher)median 95%17% (higher)median 50%
HSPF272% (higher)median 10.032% (higher)median 7.8
SEER258% (higher)median 21.531% (higher)median 15.0
EER265%median 12.687%median 12.5
Heating capacity at 5°F64% (higher)median 18,250 Btu/h23% (higher)median 14,400 Btu/h
Outdoor models1111
AHRI certifications11799

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDeyeLegacy Systems
CEE 2025 Tier 1 (Split ASHP)72.7%8 models0%0 models
CEE 2026 Tier 1 (Split ASHP)72.7%8 models0%0 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)72.7%8 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate72.7%8 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 0 groups where both have models
  • Deye
  • Legacy Systems
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDeyeLegacy Systems
Ducted, up to 1.5 tonsNone2 · index 38%
Ducted, 2 tonsNone2 · index 35%
Ducted, 2.5–3 tonsNone4 · index 46%
Ducted, 3.5–4.5 tonsNone3 · index 52%
Non-ducted, up to 1.5 tons6 · index 64%None
Non-ducted, 2 tons4 · index 67%None
Non-ducted, 2.5–3 tons1 · index 71%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDeyeCold-climate score, best modelLegacy SystemsCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Ducted, 2 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Ducted, 2.5–3 tonsNo models in this size classNone on this board (0 of 4 models qualify)
Ducted, 3.5–4.5 tonsNo models in this size classNone on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tons82.4(50 is the typical model of its size class)DWLA4-ACDC1-12KR2(US)with ductless indoor unit DGLA4-ACDC1-12KR2(US)Also listed as DWLA4-12KR2(US)3 of 6 models qualify · AHRI 216021341No models in this size class
Non-ducted, 2 tons84.5(50 is the typical model of its size class)DWLC2-ACDC-24KR2(US)with ductless indoor unit DGLA3-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)4 of 4 models qualify · AHRI 216021343No models in this size class
Non-ducted, 2.5–3 tons71.7(50 is the typical model of its size class)DW4E1-ACDC-36KR2(US)1 of 1 models qualify · AHRI 217617797No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDeyeAll-around score, best modelLegacy SystemsAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class38.8(50 is the typical model of its size class)GLZS4MA1810A*with ducted air handler AMST24BU1300A2 of 2 models have all five ratings · AHRI 215233840
Ducted, 2 tonsNo models in this size class39.6(50 is the typical model of its size class)GLZS4MA2410A*with ducted air handler AMST24BU1300A2 of 2 models have all five ratings · AHRI 215233979
Ducted, 2.5–3 tonsNo models in this size class52.0(50 is the typical model of its size class)GLZS4MA3010A*with ducted air handler AWST30LU13**A4 of 4 models have all five ratings · AHRI 215234313
Ducted, 3.5–4.5 tonsNo models in this size class53.3(50 is the typical model of its size class)GLZS4BA6010A*with ducted air handler AMST60DU1300A3 of 3 models have all five ratings · AHRI 215233838
Non-ducted, up to 1.5 tons70.7(50 is the typical model of its size class)DWLA4-ACDC1-12KR2(US)with ductless indoor unit DGLA4-ACDC1-12KR2(US)Also listed as DWLA4-12KR2(US)3 of 6 models have all five ratings · AHRI 216021341No models in this size class
Non-ducted, 2 tons72.1(50 is the typical model of its size class)DWLC2-ACDC-24KR2(US)with ductless indoor unit DGLA3-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)4 of 4 models have all five ratings · AHRI 216021343No models in this size class
Non-ducted, 2.5–3 tons70.6(50 is the typical model of its size class)DW4E1-ACDC-36KR2(US)1 of 1 models have all five ratings · AHRI 217617797No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDeyeLegacy Systems
COP at 5°Fbeats 97% · 2.23DW4E1-ACDC-36KR2(US)Non-ducted, 2.5–3 tonsbeats 56% · 2.00GLZS4BA3010A*Ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 100% · 116%DWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tonsbeats 23% · 53%GLZS4MA3010A*Ducted, 2.5–3 tons
HSPF2beats 87% · 11.0DWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tonsbeats 51% · 8.2GLZS4BA6010A*Ducted, 3.5–4.5 tons
SEER2beats 84% · 25.0DWA4-09KR2(US)Non-ducted, up to 1.5 tonsbeats 35% · 15.2GLZS4BA4210A*Ducted, 3.5–4.5 tons
EER2beats 87% · 14.5DWA4-09KR2(US)Non-ducted, up to 1.5 tonsbeats 93% · 12.5GLZS4BA4210A*Ducted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 81% · 22,000 Btu/hDWLC2-ACDC-24KR2(US)Also listed as DWLC2-24KR2(US)Non-ducted, 2 tonsbeats 46% · 8,700 Btu/hGLZS4BA1810A*Ducted, up to 1.5 tons

More comparisons