Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
MAXI AIR vs TEHANLD heat pumps
Measured against models of the same size and duct type, MAXI AIR scores higher on 6 of the 6 ratings. MAXI AIR has 10 outdoor models, TEHANLD has 10 outdoor models. MAXI AIR and TEHANLD have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- MAXI AIR
- TEHANLD
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | MAXI AIR | TEHANLD |
|---|---|---|
| Efficiency index | 75% (higher)median — | 24% (higher)median — |
| COP at 5°F | 51% (higher)median 2.00 | 17% (higher)median 1.75 |
| Capacity retention at 5°F | 83% (higher)median 98% | 34% (higher)median 70% |
| HSPF2 | 83% (higher)median 10.5 | 12% (higher)median 7.5 |
| SEER2 | 77% (higher)median 23.0 | 28% (higher)median 17.0 |
| EER2 | 77% (higher)median 12.8 | 26% (higher)median 10.2 |
| Heating capacity at 5°F | 84% (higher)median 27,000 Btu/h | 22% (higher)median 7,400 Btu/h |
| Outdoor models | 10 | 10 |
| AHRI certifications | 34 | 12 |
Share of models meeting each standard
| Standard | MAXI AIR | TEHANLD |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%10 models | 40%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%10 models | 40%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%10 models | 60%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 70%7 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- MAXI AIR
- TEHANLD
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | MAXI AIR | TEHANLD |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index 77% | None |
| Ducted, 2.5–3 tons | 5 · index 77% | None |
| Ducted, 3.5–4.5 tons | 1 · index 49% | None |
| Non-ducted, up to 1.5 tons | 4 · index 75% | 10 · index 24% |
| Non-ducted, 2.5–3 tons | 4 · index 76% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | MAXI AIRCold-climate score, best model | TEHANLDCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 70.8(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models qualify · AHRI 218381880 | No models in this size class |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models qualify · AHRI 217752780 | No models in this size class |
| Ducted, 3.5–4.5 tons | 60.5(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models qualify · AHRI 217752767 | No models in this size class |
| Non-ducted, up to 1.5 tons | 73.8(50 is the typical model of its size class) (higher)T55-AES18EXT454with ductless indoor unit T55-AES18INT4544 of 4 models qualify · AHRI 217752773 | 47.6(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH26 of 10 models qualify · AHRI 217563445 |
| Non-ducted, 2.5–3 tons | 78.0(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models qualify · AHRI 217752781 | No models in this size class |
All-around best
| Size and duct type | MAXI AIRAll-around score, best model | TEHANLDAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 77.4(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models have all five ratings · AHRI 218381880 | No models in this size class |
| Ducted, 2.5–3 tons | 83.6(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models have all five ratings · AHRI 217752780 | No models in this size class |
| Ducted, 3.5–4.5 tons | 49.1(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models have all five ratings · AHRI 217752767 | No models in this size class |
| Non-ducted, up to 1.5 tons | 81.9(50 is the typical model of its size class) (higher)T55-MULTI18E454Also listed as T55-MULTI18E4544 of 4 models have all five ratings · AHRI 218381879 | 49.3(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH210 of 10 models have all five ratings · AHRI 217563445 |
| Non-ducted, 2.5–3 tons | 78.3(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models have all five ratings · AHRI 217752779 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | MAXI AIR | TEHANLD |
|---|---|---|
| COP at 5°F | beats 63% · 2.00T55-MULTI18E454Also listed as T55-MULTI18E454Ducted, up to 1.5 tons | beats 42% · 1.90DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 97% · 107%MAXS-2430-454Ducted, 2.5–3 tons | beats 71% · 89%DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| HSPF2 | beats 94% · 10.4T55-MULTI36E454Also listed as T55-MULTI36E454Ducted, 2.5–3 tons | beats 29% · 9.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| SEER2 | beats 88% · 25.4T55-AES12EXT454Non-ducted, up to 1.5 tons | beats 56% · 22.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| EER2 | beats 91% · 15.0T55-MULTI18E454Also listed as T55-MULTI18E454Non-ducted, up to 1.5 tons | beats 44% · 12.0DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH2Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 97% · 19,000 Btu/hT55-MULTI18E454Also listed as T55-MULTI18E454Non-ducted, up to 1.5 tons | beats 34% · 8,400 Btu/hDMLHT1W-12R4CBPH2Also listed as DMLHT1W-12R4BBPH2Non-ducted, up to 1.5 tons |